The ATEX Long Throw Nozzle WDA provides powerful long-distance air distribution for large industrial halls, theatres, production areas, process buildings, and hazardous-area HVAC systems. Companies searching for an ATEX Air Diffuser in Oman can use the WDAEX where the ventilation system needs high outlet velocity, long throw distance, low sound levels, and controlled horizontal or vertical air distribution.
The long-throw nozzle uses a conical outlet geometry that creates a concentrated air jet. This design allows the WDA to deliver conditioned air over much greater distances than a standard ceiling diffuser. As a result, engineers can position the nozzles along walls or ceilings while still reaching large occupied areas.
The standard WDA range supports approximately 40–10,000 m³/h, while the ATEX WDAEX documentation covers around 20–8,000 m³/h. It can support cooling with a temperature difference up to approximately −14 K and heating up to approximately +25 K.
For hazardous locations, the WDAEX supports Zones 1 and 2 for gases and Zones 21 and 22 for combustible dusts. The certified ATEX markings are II 2G Ex h IIB Gb and II 2D Ex h IIIC Db.
Atex Hub supplies ATEX Air Diffusers across Muscat, Sohar, Salalah, Duqm, Nizwa, Sur, and throughout Oman. We also support projects across the UAE, Saudi Arabia, Qatar, Kuwait, Bahrain, Europe, Africa, and worldwide.
The ATEX Long Throw Nozzle WDA is a high-velocity air terminal designed to project conditioned supply air over long distances.
Unlike a conventional ceiling diffuser that spreads air across a nearby area, the WDA creates a focused jet with deeper penetration.
This makes it particularly useful in:
The ATEX Air Diffuser in Oman combines long throw, high airflow, adjustable direction, and certified hazardous-area suitability.
The WDA creates a focused high-speed air jet.
A typical supply-air sequence works as follows:
This operating principle allows one nozzle to cover a larger area than many conventional diffusers.
The WDA provides deep air penetration because of its concentrated discharge pattern.
Long-throw distribution offers several advantages:
This design works particularly well in large industrial buildings and production halls.
The WDA supports cooling with supply-air temperature differences up to approximately −14 K.
During cooling:
Correct cooling selection remains important because a nozzle designed only for heating can produce draughts during cooling.
The WDA can also operate with heating temperature differences up to approximately +25 K.
Warm air naturally rises, so heating applications often require stronger downward penetration.
The nozzle can support this through:
This helps warm air reach lower occupied zones in large halls.
Selected WDA models include a swivel head.
The swivel arrangement allows the nozzle to move approximately 20–30°.
This adjustment can be:
The swivel mechanism helps engineers change between heating and cooling throw patterns or adapt airflow after changes to room layout.
A swirl disc can shorten the effective jet throw where the installation does not require maximum penetration.
The swirl disc:
This option becomes useful where a concentrated jet would otherwise travel too far.
The ATEX version carries certified hazardous-area markings.
| ATEX Parameter | Product Classification |
|---|---|
| Product Version | WDAEX |
| Equipment Group | Group II |
| Gas Marking | II 2G Ex h IIB Gb |
| Dust Marking | II 2D Ex h IIIC Db |
| Gas Zones | Zone 1 / Zone 2 |
| Dust Zones | Zone 21 / Zone 22 |
| Gas Group | IIB |
| ATEX Certificate | EPS 18 ATEX 2 052 U |
| Operating Temperature | Approx. 0–60°C |
| Ambient Temperature | Approx. 0–60°C |
| ATEX Airflow Range | Approx. 20–8,000 m³/h |
The WDAEX also supports use with gas environments within its approved IIB classification.
ATEX installation requires reliable electrical bonding.
The WDAEX must connect conductively to the ventilation duct network and the local equipotential-bonding system.
Installation teams should therefore:
Proper grounding helps reduce ignition hazards from static discharge.
The WDA family supports several installation arrangements.
| Model | Installation |
| WDA-N | Nozzle without installation components |
| WDA-F | Flexible duct connection |
| WDA-W | Spiral duct connection |
| WDA-D | Wall or ceiling installation |
| WDA-K | Duct installation |
| WDA-R | Duct connection with saddle bracket |
| WDA-SK | Version with swivel head |
This wide selection helps engineers integrate the nozzle into both new and existing HVAC systems.
The WDA-W configuration can connect directly to suitable spiral duct systems.
For ATEX WDAEX installations, technicians should avoid stressing or deforming the nozzle connection.
The spiral duct should remain round and properly aligned so that:
For size 400, the connection spigot requires on-site installation according to the ATEX technical instructions.
The Hazardous Area Air Diffuser supports large-volume and long-throw HVAC applications.
| Specification | Product Details |
| Product Name | ATEX Long Throw Nozzle WDA |
| ATEX Version | WDAEX |
| Product Type | Long throw supply-air nozzle |
| Airflow Range – Standard | Approx. 40–10,000 m³/h |
| Airflow Range – ATEX | Approx. 20–8,000 m³/h |
| Cooling Temperature Difference | Up to approx. −14 K |
| Heating Temperature Difference | Up to approx. +25 K |
| Air Pattern | Horizontal / vertical |
| Swivel Adjustment | Approx. 20–30° |
| Adjustment | Manual or motorised |
| Installation | Wall, ceiling, duct or spiral duct |
| Optional Swirl Disc | Available |
| Gas Zones | Zone 1 / Zone 2 |
| Dust Zones | Zone 21 / Zone 22 |
| Gas Marking | II 2G Ex h IIB Gb |
| Dust Marking | II 2D Ex h IIIC Db |
| ATEX Certificate | EPS 18 ATEX 2 052 U |
| Operating Temperature | Approx. 0–60°C |
| Ambient Temperature | Approx. 0–60°C |
| Pressure Loss | Low relative to long-throw performance |
| Primary Application | Large-room supply-air distribution |
Correct selection helps the WDA provide reliable air throw and maintain hazardous-area safety.
The WDAEX supports important hazardous-area and HVAC requirements.
Atex Hub supplies ATEX Air Diffusers and long-throw air terminals for hazardous HVAC, industrial climate control, high-ceiling spaces, and large-volume ventilation projects.
1. What is the ATEX Long Throw Nozzle WDA?
The WDAEX is an ATEX-certified long-throw supply-air nozzle designed to deliver conditioned air over large distances.
2. Can I use it as an ATEX Air Diffuser in Oman?
Yes. The WDAEX supports certified hazardous-area installations in Zones 1, 2, 21 and 22 when engineers follow the approved ATEX conditions.
3. What is the gas ATEX marking?
The gas marking is II 2G Ex h IIB Gb.
4. What is the dust ATEX marking?
The dust marking is II 2D Ex h IIIC Db.
5. What airflow range does the ATEX version support?
The WDAEX supports approximately 20 to 8,000 m³/h.
6. Can the WDA provide heating and cooling?
Yes. It supports cooling up to approximately Δt −14 K and heating up to approximately Δt +25 K.
7. Can the nozzle direction be adjusted?
Yes. Swivel-head versions can move approximately 20–30° manually or by motor.
8. Can the WDA connect to spiral ducting?
Yes. The WDA-W configuration supports spiral duct connection.
9. Does the ATEX version require grounding?
Yes. The WDAEX must connect to the equipotential-bonding and grounding system.
10. Can Atex Hub supply the complete long-throw HVAC system?
Yes. Atex Hub supplies ATEX long-throw nozzles, ducting, fans, AHUs, dampers, filters, actuators, controls, and related hazardous-area HVAC equipment.
The ATEX Long Throw Nozzle WDA provides powerful and controlled air distribution for large rooms, industrial halls, and hazardous-area HVAC systems.
Its conical nozzle geometry creates high outlet velocity while maintaining comparatively low sound levels. This allows the WDA to achieve long throw distances in both heating and cooling applications.
The standard WDA family supports approximately 40–10,000 m³/h, while the certified WDAEX covers approximately 20–8,000 m³/h and operates in ambient conditions around 0–60°C. It supports Zones 1, 2, 21 and 22 with markings II 2G Ex h IIB Gb and II 2D Ex h IIIC Db.
For companies searching for an ATEX Air Diffuser in Oman, the WDA supports oil and gas facilities, petrochemical plants, chemical industries, production halls, warehouses, theatres, event spaces, and high-ceiling industrial HVAC applications.
Atex Hub supplies ATEX Air Diffusers throughout Oman, the GCC, Europe, Africa, and worldwide.