Keeping people and equipment safe in hot, hazardous environments isn’t optional—it’s essential. The ATEX Air Conditioner delivers reliable cooling (and optional heating) for areas where flammable gas or combustible dust may be present. It uses explosion-protected components, controlled surface temperatures, and rugged enclosures so you can stabilize temperature and humidity without adding risk. In simple words: cool, safe, and built to last.
What is ATEX Air Conditioner
An ATEX Air Conditioner is a climate-control system designed for ATEX-classified zones. It’s engineered to prevent sparks or hot surfaces from becoming an ignition source. Unlike standard ACs, it features certified electrical parts, sealed control panels, Ex-rated cable glands, strict temperature-class control, and markings that match your zone and gas/dust group. You can use it in Zone 1/2 (gas) and Zone21/22 (dust) locations when the correct model and certification are selected. It’s a proven way to protect people, electronics, and processes in oil & gas, chemicals, batteries, marine, food, and more.
Key uses of ATEX Air Conditioner
Protects people: Keeps workspaces comfortable so teams stay alert and productive.
Protects electronics: Stabilizes temperature in analyzer shelters, MCC rooms, and PLC cabinets.
Reduces risk: Ex designs limit ignition sources in classified areas.
Improves quality: Consistent climate supports paint mixing, batching, and precision work.
Boosts uptime: Rugged parts, better filtration, and smart alarms cut unplanned stops.
Key applications
Oil & Gas: wellheads, compressor stations, analyzer shelters, E-houses.
Chemicals & Pharma: solvent handling rooms, mixing areas, controlled spaces.
Energy & Batteries: charging rooms, hydrogen sites, BESS containers (per risk assessment).
Painting & Coatings: paint kitchens and solvent stores.
Food & Agriculture: mills, grain, sugar, and flour handling (dust zones).
Marine & Offshore: accommodation modules, control cabins, and process skids.
Why choose ATEX Air Conditioner?
Safe by design: prevents ignition sources.
Built for your zone: gas or dust, Zone 1/2 and 21/22.
Durable: resists heat, dust, salt, and vibration.
Simple to own: easy controls, clear documentation.
Flexible formats: split, ducted, rooftop, and packaged options.
Connects easily: BMS/DCS integration for alarms and status.
Fully certified: supplied with Ex nameplate and conformity docs.
Technical Specifications
| Parameter | Specification |
|---|---|
| Hazardous Area Use | Gas Zones 1 & 2; Dust Zones 21 & 22 |
| ATEX Equipment Group/Category | II 2G (Zone 1), II 3G (Zone 2), II 2D (Zone 21), II 3D (Zone 22) |
| Example Gas Marking | II 2G Ex db eb IIB T4 Gb (IIC and T3/T4 variants subject to model) |
| Example Dust Marking | II 2D Ex tb IIIC T135 °C Db |
| Protection Concepts | Ex db/eb (flameproof + increased safety), Ex p (pressurization) for enclosures, Ex tb (dust) |
| Temperature Class (Gas) | T4 (≤135 °C) typical; T3 available based on duty |
| Ingress Protection | Up to IP66 outdoors; IP54–IP66 control panels |
| Cooling Capacity | ~3.5–18 kW (12,000–61,000 BTU/h); larger frames up to ~35 kW on request |
| Heating Options | Heat pump ~3.2–16 kW; or electric heater 2–9 kW (model-dependent) |
| Airflow | ~500–2,200 m³/h (filter grade & static pressure dependent) |
| Ambient Range | −20 °C to +55 °C (high-ambient kits to +60 °C; low-ambient start kits available) |
| Refrigerants (A1 class) | R134a, R407C, R410A (final choice per risk assessment and local rules) |
| Power Supply | 230 V 1-ph 50/60 Hz (small units) or 400 V 3-ph 50/60 Hz (medium/large) |
| Controls & Safeties | Ex thermostat, HP/LP switches, anti-short-cycle, over-temp cut-out, E-stop |
| BMS/Integration | Volt-free contacts; Modbus RTU/RS-485 (with certified barriers if required) |
| Filtration | G4 standard; F7/F9 fine filters and sand-trap louvers optional |
| Coils & Anti-Corrosion | Epoxy-coated coils; C3–C5 packages; 304/316L housings optional |
| Cable Entries | Ex e certified glands (e.g., M20/M25/M32) supplied/blanked as specified |
| Mounting Styles | Split wall/ducted/cassette, packaged rooftop, precision in-cabinet variants |
| Noise (indoor) | ≤65 dB(A) @ 1 m typical (arrangement dependent) |
| Documentation | ATEX Declaration, nameplate, wiring diagram, O&M manual, EC/DoC where applicable |
| Warranty | 12 months standard; extended options available |
Compliance, Certifications & Standards (official links only)
ATEX Directive 2014/34/EU (Equipment for Explosive Atmospheres) – EUR-Lex:
IECEx Scheme (International Certification for Ex Equipment):
IEC/EN 60079 series (Explosive Atmospheres – electrical equipment and protection methods):
ISO/IEC 80079-36/37 (Non-electrical equipment for explosive atmospheres):
FAQs
1) Which zones does this unit cover?
Models are available for Zone 1/2 (gas) and Zone 21/22 (dust). We match the Ex marking to your dossier.
2) How do I choose the right temperature class (T-class)?
T-class limits surface temperature. It’s set by your gas/dust properties and risk study. T4 is common; we’ll confirm during selection.
3) Can it connect to our BMS/DCS?
Yes. You can monitor alarms and status via dry contacts or Modbus RTU (with certified barriers where needed).
4) What about refrigerant safety?
We select A1-class (non-flammable) refrigerants such as R134a, R407C, or R410A, aligned with your risk assessment and local rules.
5) Do I need stainless steel outdoors or offshore?
For marine or corrosive sites, 304/316L housings and coated coils (C5) extend service life.
6) How is maintenance different from a normal AC?
Intervals are similar, but procedures follow Ex rules. Use certified parts and keep records for audits.
7) Can you supply packaged or split systems?
Yes—split, ducted, rooftop, and precision variants are available so we can fit the space and duty.
Conclusion
The ATEX Air Conditioner helps you control heat and humidity without compromising safety. It’s built for tough sites, simple to operate, and fully documented for compliance. This product is available at ATEX HUB. Share your zone, gas group, T-class, cooling/heating load, and ambient conditions, and we’ll size and configure the ideal unit for your site.