If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The KEL-DPZ Round ATEX Cable Entry Plates provide a compact round cable entry solution for routing and sealing standard cables through metric enclosure cut-outs. These cable entry plates help installers pass multiple standard cables or pneumatic hoses through panels, junction boxes, control cabinets, machine housings, and industrial enclosures while maintaining strong sealing performance.
For companies searching for Intrinsically Safe Cable Entry Plates in Kuwait, this product suits ATEX cable entry systems, explosion proof cable entry systems, flame proof cable entry systems, hazardous area cable entry systems, and intrinsically safe cable entry systems search requirements. It supports cable entry, cable sealing, cable routing, panel wiring, high-density cable management, machine wiring, instrumentation cabling, and hazardous-area enclosure projects.
Atex Hub supplies intrinsically safe cable entry plates and hazardous-area cable entry systems globally across Kuwait, UAE, Saudi Arabia, Qatar, Oman, Bahrain, Europe, Africa, and worldwide, helping industries source suitable cable entry products for control panels, cabinets, machines, junction boxes, and industrial systems.
The KEL-DPZ Round ATEX Cable Entry Plates are round cable entry plates designed to route and seal standard cables in limited enclosure space. They support standard cables from 1.5 mm to 22 mm in diameter and allow quick installation through metric cut-outs from M32 to M63. Installers create a small slit in the membrane, push the standard cable through, and the sealing plate immediately seals the cable entry to IP66 / IP67 / IP68.
These round cable entry plates use a polyamide thread frame and an elastomer sealing plate. The product data lists UL94-V0 self-extinguishing flame class, IP68, -30°C to +90°C static temperature range, equipment group II, categories 2G, 3G, 2D, 3D, zones 1 + 21 and 2 + 22, test standard EN 60079-0, and halogen-free / silicone-free properties.
The round KEL-DPZ ATEX design fits standard metric cable gland cut-outs. This helps panel builders and maintenance teams replace multiple individual cable glands with one compact cable entry plate where the full enclosure approval and site requirement allow it.
The KEL-DPZ Round ATEX Cable Entry Plates give installers a compact and fast cable entry method for standard cables. They support dense cable routing, cable sealing, metric thread mounting, Ex-area enclosure layouts, and quick installation.
The product data highlights assembly within seconds, high packing density, dual sealing of cables according to IP66 / IP67 / IP68, and suitability for standard or metric cut-outs.
The KEL-DPZ Round ATEX Cable Entry Plates help industries route standard cables through enclosure walls, junction boxes, cabinets, and machine panels. They suit projects where installers need compact cable entry, fast assembly, high cable density, metric cut-out compatibility, and reliable sealing.
| Specification | Details |
|---|---|
| Product Name | KEL-DPZ Round ATEX Cable Entry Plates |
| Product Type | ATEX / Intrinsically Safe / Hazardous Area Round Cable Entry Plate |
| Main Use | Routing and sealing standard cables |
| Cable Diameter Range | 1.5 mm to 22 mm |
| Metric Threads | M32, M40, M50, M63 |
| Protection Class | IP68 |
| Sealing Performance | IP66 / IP67 / IP68 |
| Thread Frame Material | Polyamide (PA) |
| Sealing Plate Material | Elastomer |
| Colour Options | Grey similar RAL 7035, black |
| Flame Class | UL94-V0, self-extinguishing |
| Temperature Range | -30°C to +90°C static |
| Equipment Group | II |
| Category | 2G, 3G, 2D, 3D |
| Zone Suitability | 1 + 21, 2 + 22 |
| Test Standard | EN 60079-0 |
| Properties | Halogen free, silicone free |
| Thread Length | 14 mm |
| Height | 8 mm |
| Included Accessory | Polyamide locknut |
| Supplier | Atex Hub |
The KEL-DPZ round ATEX specification section lists polyamide thread frame, elastomer sealing plate, UL94-V0, IP68, -30°C to +90°C, equipment group II, categories 2G, 3G, 2D, 3D, zones 1 + 21 and 2 + 22, and EN 60079-0.
The KEL-DPZ Round ATEX Cable Entry Plates range includes several metric thread options and cable layouts. Project teams should select the correct version based on cable diameter, cable count, metric thread size, external diameter, enclosure cut-out, and IP requirement.
| Product Type | Cable Capacity / Diameter Range | Metric Thread | External Diameter |
|---|---|---|---|
| KEL-DPZ 32/4 ATEX | 3 × 3.2–6.5 mm + 1 × 7.2–12.5 mm | M32 | 44 mm |
| KEL-DPZ 32/4-2 ATEX | 4 × 5–9.5 mm | M32 | 44 mm |
| KEL-DPZ 32/7 ATEX | 7 × 3.2–6.5 mm | M32 | 44 mm |
| KEL-DPZ 40/8 ATEX | 4 × 3.2–6.5 mm + 4 × 5–10.2 mm | M40 | 52 mm |
| KEL-DPZ 50/8 ATEX | 5 × 5–10.2 mm + 3 × 7.2–12.5 mm | M50 | 62 mm |
| KEL-DPZ 50/10 ATEX | 7 × 3.2–6.5 mm + 2 × 5–10.2 mm + 1 × 16–22.2 mm | M50 | 62 mm |
| KEL-DPZ 50/12 ATEX | 4 × 3.2–6.5 mm + 8 × 5–10.2 mm | M50 | 62 mm |
| KEL-DPZ 50/19 ATEX | 19 × 3.2–6.5 mm | M50 | 62 mm |
| KEL-DPZ 50/78 ATEX | 76 × 1.5–2.6 mm + 2 × 2.5–5 mm | M50 | 62 mm |
| KEL-DPZ 63/9 ATEX | 1 × 3.2–6.5 mm + 3 × 5–10.2 mm + 4 × 9–16.2 mm + 1 × 16–22.2 mm | M63 | 75 mm |
| KEL-DPZ 63/13 ATEX | 4 × 3.2–6.5 mm + 4 × 5–10.2 mm + 5 × 9–16.2 mm | M63 | 75 mm |
| KEL-DPZ 63/14 ATEX | 14 × 5–10.2 mm | M63 | 75 mm |
| KEL-DPZ 63/35 ATEX | 35 × 3.2–6.5 mm | M63 | 75 mm |
The product range lists round cable entry plates from M32 to M63, with external diameters from 44 mm to 75 mm, and cable layouts ranging from 4 cables up to 78 cable entries depending on model.
The correct Intrinsically Safe Cable Entry Plates in Kuwait selection depends on cable diameter, cable count, enclosure thread size, hazardous-area zone, IP rating, colour requirement, and installation method.
| Selection Point | What to Check |
|---|---|
| Cable Type | Confirm standard cables or pneumatic hoses |
| Cable Diameter | Select a layout for cables from 1.5 mm to 22 mm |
| Cable Count | Choose the model that matches the number of cables required |
| Metric Thread | Select M32, M40, M50, or M63 |
| External Diameter | Confirm available space around the enclosure entry point |
| IP Requirement | Confirm whether IP66 / IP67 / IP68 is required |
| Hazardous Zone | Confirm Zone 1, Zone 2, Zone 21, or Zone 22 suitability |
| Gas / Dust Area | Confirm whether the project involves gas, dust, or both |
| Material Requirement | Confirm polyamide frame and elastomer sealing plate suitability |
| Cable Support | Use fixed cable installation where pulling and torsion do not affect the cable entry |
| Compliance | Confirm datasheet, certificate, enclosure approval, cable layout, and site classification before procurement |
Round cable entry plates allow several cables to pass through one metric cable gland cut-out. This helps reduce the number of individual cable glands, saves enclosure space, and improves cable organisation.
The KEL-DPZ Round ATEX design fits metric cut-outs from M32 to M63, so teams can use standard cable gland openings for multi-cable entry. This makes the product useful for control panels, compact junction boxes, instrumentation cabinets, machine housings, and retrofit projects.
Industrial cable entry points often face dust, humidity, water spray, washdown, and outdoor exposure. IP66 supports strong water-jet protection, IP67 supports temporary immersion protection, and IP68 supports higher ingress protection when the full installed assembly maintains the rating.
For Kuwait projects, this matters in Mina Al Ahmadi, Shuaiba, Al Zour, Mina Abdullah, Ahmadi, ports, refineries, petrochemical facilities, utilities, factories, workshops, and outdoor control panel locations. Correct membrane slitting, cable diameter matching, thread mounting, locknut tightening, and enclosure preparation help maintain sealing performance.
High packing density helps route many cables through a smaller enclosure opening. This reduces drilling work, saves panel space, and improves wiring organisation inside control cabinets, junction boxes, instrumentation panels, and machine housings.
The KEL-DPZ round range includes high-density versions such as KEL-DPZ 50/78 ATEX and KEL-DPZ 63/35 ATEX, which support many small cable entries through one round metric opening.
The product data describes a membrane on the front and a conical shape on the back that provides additional sealing. This design helps the sealing plate grip the cable more effectively after insertion.
This matters because cable entry points can fail if the membrane tears too much, if the cable diameter does not match the opening, or if the cable is pulled after installation. Installers should create only a small slit and keep cables fixed after routing.
The ATEX cable entry information states that the cable entry is only suitable for fixed cable installation where strain and torsional loading on the cable are not possible.
This matters because pulling force, bending stress, or twisting can reduce sealing performance. Installers should route, clamp, and support cables correctly so movement does not affect the cable entry plate.
Many buyers use ATEX cable entry systems, explosion proof cable entry systems, flame proof cable entry systems, hazardous area cable entry systems, and intrinsically safe cable entry systems together. However, each term can describe a different cable entry or enclosure requirement.
| Term | Meaning |
|---|---|
| ATEX Cable Entry Systems | Cable entry products selected for Ex-rated enclosure projects where approval allows |
| Explosion Proof Cable Entry Systems | Cable entry products used in hazardous-area enclosure applications |
| Flame Proof Cable Entry Systems | Cable entry systems selected for flameproof or Ex-rated projects |
| Hazardous Area Cable Entry Systems | Cable entry systems used in classified gas, vapour, dust, or industrial areas |
| Intrinsically Safe Cable Entry Systems | Cable entry systems used with approved low-energy Ex i wiring and compliant enclosures |
| Round Cable Entry Plate | Round plate used to route several standard cables through one metric cut-out |
| Elastomer Sealing Plate | Flexible sealing plate that closes around cables after insertion |
| High-Density Cable Entry | Cable entry method designed to route many cables through limited space |
This difference matters in Kuwait projects because consultants, EPC contractors, safety teams, and inspectors may ask for a specific protection method. Always confirm whether the project needs ATEX certification, Zone 1, Zone 2, Zone 21, Zone 22, IP66, IP67, IP68, EN 60079-0, UL94-V0, fixed cable installation, or intrinsically safe wiring selection.
Correct installation helps the KEL-DPZ Round ATEX Cable Entry Plates perform safely and reliably. The installer must check cable diameter, cable count, metric thread size, hazardous-area classification, membrane condition, cable support, enclosure approval, and locknut fixing before installation.
Certifications and standards help buyers select the correct round cable entry plate for hazardous-area and industrial enclosure projects. The final selection must match the enclosure design, hazardous zone, gas or dust classification, IP requirement, cable count, cable diameter, metric thread size, and site inspection standard.
The KEL-DPZ Round ATEX product data lists equipment group II, categories 2G, 3G, 2D, 3D, zones 1 + 21 and 2 + 22, test standard EN 60079-0, and protection class IP68. It also lists dual cable sealing according to IP66 / IP67 / IP68.
The KEL-DPZ Round ATEX Cable Entry Plates give industries a compact and efficient solution for routing and sealing standard cables in industrial and hazardous-area enclosure projects. They support 1.5 mm to 22 mm cable diameters, M32 to M63 metric cut-outs, IP66 / IP67 / IP68 sealing performance, polyamide thread frame, elastomer sealing plate, UL94-V0 flame class, -30°C to +90°C static temperature, equipment group II, 2G / 3G / 2D / 3D categories, and Zone 1 / 21 and Zone 2 / 22 applications.
For Kuwait projects, these cable entry plates suit oil & gas, petrochemical, refinery, automation, control panels, machine building, industrial enclosures, utilities, factories, warehouses, workshops, process plants, ports, skids, maintenance panels, and infrastructure applications. Their round metric design, fast membrane entry, high packing density, dual sealing, and included locknut make them useful for demanding cable entry and cable management work.
1. What are KEL-DPZ Round ATEX Cable Entry Plates used for?
They route and seal multiple standard cables through one round metric enclosure opening.
2. Are these suitable for Intrinsically Safe Cable Entry Plates in Kuwait projects?
Yes, they can suit Kuwait Ex i and hazardous-area enclosure projects when the enclosure approval, wiring method, IP rating, cable layout, and site classification match the requirement.
3. What cable diameter range does KEL-DPZ Round ATEX support?
The product range supports standard cables from 1.5 mm to 22 mm in diameter.
4. What IP rating does the round cable entry plate provide?
The product data lists IP68 and dual sealing according to IP66 / IP67 / IP68.
5. What metric thread sizes are available?
The round versions fit metric cut-outs from M32 to M63.
6. What material does the cable entry plate use?
It uses a polyamide thread frame and an elastomer sealing plate.
7. What temperature range does it support?
It supports -30°C to +90°C static temperature range.
8. What hazardous zones are listed for KEL-DPZ Round ATEX?
The product data lists Zone 1 + 21 and Zone 2 + 22 suitability.
9. Where can it be used in Kuwait?
It suits Kuwait City, Mina Al Ahmadi, Shuaiba, Al Zour, Mina Abdullah, Ahmadi, ports, refineries, petrochemical units, utilities, factories, workshops, control panels, and infrastructure sites.
10. Who supplies intrinsically safe cable entry plates globally?
Atex Hub supplies intrinsically safe cable entry plates and hazardous-area cable entry systems across Kuwait, UAE, Saudi Arabia, Qatar, Oman, Bahrain, Europe, Africa, and worldwide.
The KEL-DPZ Round ATEX Cable Entry Plates give industries a compact round solution for routing and sealing standard cables in industrial and hazardous-area enclosure projects. They support 1.5 mm to 22 mm cable diameters, M32 to M63 metric cut-outs, IP66 / IP67 / IP68 sealing performance, polyamide thread frame, elastomer sealing plate, UL94-V0 flame class, -30°C to +90°C static temperature, equipment group II, 2G / 3G / 2D / 3D categories, and Zone 1 / 21 and Zone 2 / 22 applications.
For buyers searching for Intrinsically Safe Cable Entry Plates in Kuwait, this product offers strong value for control panels, automation systems, machine building, industrial enclosures, retrofit work, maintenance panels, utility systems, factories, workshops, warehouses, ports, process plants, oilfields, refineries, and infrastructure projects. Its round metric design, fast assembly, high packing density, dual sealing, and space-saving installation make it suitable for demanding cable entry systems.
Atex Hub supplies KEL-DPZ Round ATEX cable entry plates and other hazardous-area cable entry systems globally across Kuwait, UAE, Saudi Arabia, Qatar, Oman, Bahrain, Europe, Africa, and worldwide, helping industries source suitable Ex-rated cable entry and enclosure accessory products.