If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
Bring safe, steady warmth to hazardous sites across the UAE. The Explosion Proof Hydronic Heater – 3-Phase 208V, 50Hz is an ATEX-rated hydronic unit heater that uses a hot water or glycol loop (hydronic heating system) and an explosion-proof fan/motor assembly to deliver reliable space heating without introducing ignition risks. Built for Dubai coastal air, Abu Dhabi refineries, and Sharjah industrial zones, this Atex hydronic heater combines rugged construction with quiet, efficient operation—perfect for pump rooms, analyser shelters, MCCs, workshops, and equipment enclosures where safety and uptime matter. Supplied locally by Atex Hub, it’s your go-to hydronic heater in the UAE.
A hydronic heater (also called a hydronic unit heater) warms air by blowing it across a finned coil carrying hot water or water-glycol from a boiler or heat exchanger. Unlike direct electric space heaters, a hydronic system shifts most heat generation away from the classified area, reducing on-site electrical heat load. This Explosion Proof Hydronic Heater – 3-Phase 208V, 50Hz adds ATEX/IECEx protection to the fan/motor assembly, IP66/67 sealing, and corrosion-resistant materials—so you can safely circulate warm air in Zone 1/2 gas or Zone 21/22 dust areas around Dubai, Abu Dhabi, and Sharjah.
Personnel comfort heating in workshops, control rooms, and shelters without open elements.
Condensation control around panels and instruments during cooler nights or shutdowns.
Process area background heat for pump skids, dosing rooms, and packaging zones.
Frost protection for exposed spaces and doorways in winter or chilled stores.
Air mixing/recirculation to even out hot and cold spots in large industrial bays.
Oil & Gas / Petrochem (Dubai, Abu Dhabi): Analyzer shelters, compressor halls, metering skids.
Marine & Ports (UAE): Jetty buildings, engine-room ancillaries, deck houses.
Chemicals & Paints (Sharjah): Solvent stores, blending rooms (per zone classification).
Utilities & Power: Battery rooms (non-IS circuits externalized), water treatment galleries.
Logistics & Warehousing: Ex-classified stores and staging areas needing quiet, clean heat.
Explosion-proof safety: Atex approved heater with flameproof motor/terminal housing for Hazardous Area zones.
Efficient & quiet: Hydronic coil + axial fan gives high output with low noise and no glowing elements.
Built for Gulf climates: IP66/67, UV-stable coatings, and corrosion-resistant coil options handle dust, salt, and humidity.
Easy integration: Works with existing hydronic heating systems; simple 3-phase hook-up for the fan set.
Flexible mounting: Wall or ceiling brackets; horizontal or vertical discharge patterns.
Local supply & support: Atex Hub provides selection, documentation, and after-sales service across the UAE.
| Item | Detail |
|---|---|
| Product Name | Explosion Proof Hydronic Heater – 3-Phase 208V, 50Hz |
| Heater Type | Atex hydronic unit heater (hot water / water-glycol coil + explosion-proof fan) |
| Electrical Supply (Fan/Motor) | 208 V, 3-Phase, 50 Hz (other voltages on request) |
| Certification | ATEX / IECEx (gas and/or dust variants) |
| Zone Classification | Gas: Zone 1 / Zone 2; Dust: Zone 21 / Zone 22 (model dependent) |
| Protection Concepts | Ex d flameproof and/or Ex e increased safety (motor/terminal) |
| Ingress Protection | IP66 / IP67 (IEC 60529) |
| Coil Circuit | Closed-loop hydronic (water or 20–50% glycol mix typical) |
| Coil Materials | Copper tubes / aluminium fins (std); Cu-Ni / SS options for marine/corrosive duty |
| Connections | ¾”–1½” NPT/BSP (size per model) |
| Airflow | 1,000–5,000 m³/h (model dependent) |
| Throw / Coverage | Up to 20–30 m (site dependent; use layout calc) |
| Temp Range (Ambient) | −20 °C to +55 °C (extended ranges available) |
| Mounting | Wall/ceiling brackets; horizontal or vertical discharge |
| Controls | Remote on/off, thermostat, RTD, flow/return sensors; BMS/PLC integration |
| Finish | Epoxy-polyester coated casing; marine topcoat option |
| Documentation | Datasheet, wiring diagram, test reports, nameplate, ATEX/IECEx certs |
ATEX Directive 2014/34/EU – equipment for explosive atmospheres
IECEx Scheme – international conformity for Ex equipment
EN 60079-0 – Explosive atmospheres: General requirements
EN 60079-1 – Flameproof enclosure “d”
EN 60079-7 – Increased safety “e”
IEC 60529 – IP ratings (IP66/IP67)
1) Can this hydronic heater be used in Dubai coastal plants?
Yes—IP66/67 enclosure, epoxy coating, and optional Cu-Ni/SS coils suit saline air and washdown.
2) What heat source do I need in Abu Dhabi facilities?
A boiler or heat exchanger providing hot water/water-glycol; the heater then circulates warm air via an Ex-rated fan.
3) Is it quieter than direct electric unit heaters?
Typically yes. There are no glowing elements; the fan/motor is Ex-rated and optimized for low noise.
4) How do I size the coil and airflow in Sharjah warehouses?
Provide room volume, design temperatures, heat loss, and available water temps/flow. Atex Hub will calculate duty and coverage.
5) Can it integrate with our BMS/PLC?
Absolutely—use thermostat/RTD signals, fan contactors, and safeties for full control and monitoring.
6) Is an intrinsically safe version available?
The drive is typically Ex d/Ex e. IS (intrinsically safe) loops can be applied to control/monitor points using certified barriers.
7) What maintenance is required in the UAE climate?
Periodic coil cleaning, strainer checks, fan guard inspection, and verification of motor glands/seals per Ex maintenance routines.
For safe, comfortable heating in hazardous areas across the UAE, choose the Explosion Proof Hydronic Heater – 3-Phase 208V, 50Hz. It pairs hydronic efficiency with ATEX/IECEx safety, robust IP66/67 protection, and dependable airflow—ideal for Dubai, Abu Dhabi, and Sharjah sites. With Atex Hub support, you’ll get proper selection, documentation, and long-term reliability from a system designed for Gulf conditions.