

If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The Ex Rotary Switch 0, 2-Pole, 16A, Max 660V AC, IP56 provides safe rotary switching and local circuit control in hazardous gas areas. It helps operators switch electrical circuits, isolate small loads, control field equipment, and manage local ON/OFF operations where explosive atmospheres may occur.
For companies searching for Flame Proof Rotary Switch in Qatar, this product suits ATEX rotary switch, explosion proof rotary switch, flame proof rotary switch, intrinsically safe rotary switch, and hazardous area rotary switch requirements. It works well in oil & gas plants, LNG facilities, refineries, petrochemical sites, marine projects, ports, utilities, factories, control panels, workshops, and industrial automation systems.
Atex Hub supplies flame proof rotary switches globally across Qatar, UAE, Saudi Arabia, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide, helping industries source certified hazardous-area switching and control solutions.
The Ex Rotary Switch 0, 2-Pole, 16A, Max 660V AC, IP56 is an explosion-protected rotary switch used for hazardous-area electrical control. The product listing identifies it as an Ex brass rotary switch with Product ID 122412, 2-pole switching, 16A rating, maximum 660V AC, IP56, and marking ATEX II 2G Eex ed IIC T6.
The listing also gives the product dimensions as 130 mm length, 135 mm width, 115 mm height, and 1600 g weight, making it a compact Ex rotary switch option for marine and industrial hazardous-area applications.
The Ex rotary switch 0, 2-pole, 16A gives industrial teams a reliable hazardous-area switching solution for local electrical control. It supports safe operation where gas, vapour, industrial exposure, marine conditions, and classified-area electrical safety requirements are important.
The product page lists the item under Explosion Proof Equipment > Ex Wiring Accessories > Ex Brass Rotary Switch, with Product ID 122412 and ISSA code 7309302.
The Ex rotary switch 0, 2-pole, 16A helps operators control and switch circuits safely in classified industrial locations. It suits projects where normal rotary switches cannot meet hazardous-area protection and industrial safety requirements.
| Specification | Details |
|---|---|
| Product Name | Ex Rotary Switch 0, 2-Pole, 16A, Max 660V AC, IP56 |
| Product Type | ATEX / Explosion Proof / Flame Proof Rotary Switch |
| Product ID | 122412 |
| ISSA Code | 7309302 |
| Switch Position | 0 position / ON-OFF style rotary control |
| Pole Configuration | 2-pole |
| Current Rating | 16A |
| Voltage Rating | Max. 660V AC |
| IP Rating | IP56 |
| ATEX Marking | ATEX II 2G Eex ed IIC T6 |
| Product Group | Ex Brass Rotary Switch |
| Length | 130 mm |
| Width | 135 mm |
| Height | 115 mm |
| Weight | 1600 g |
| Supplier | Atex Hub |
The source page lists Product ID 122412, ISSA code 7309302, length 130 mm, width 135 mm, height 115 mm, and weight 1600 g.
The correct flame proof rotary switch depends on the hazardous zone, protection marking, current rating, voltage rating, pole configuration, IP protection, material, cable entry layout, and project approval requirement.
| Selection Point | What to Check |
|---|---|
| Hazardous Area Marking | Confirm ATEX II 2G Eex ed IIC T6 requirement |
| Gas Group | Confirm whether IIC gas group suits the site |
| Temperature Class | Confirm T6 temperature class requirement |
| Current Rating | Check whether 16A suits the connected circuit |
| Voltage Rating | Confirm whether 660V AC max matches the design |
| Pole Configuration | Confirm whether 2-pole switching is required |
| Ingress Protection | Confirm whether IP56 suits indoor, outdoor, or marine use |
| Material Requirement | Confirm brass rotary switch suitability for the project |
| Installation Area | Check mounting space, cable entries, and operator access |
| Compliance | Confirm datasheet, ATEX marking, and site inspection requirement |
The marking Eex ed IIC T6 indicates an explosion-protected design that uses a combination of protection concepts. In simple terms, Ex e relates to increased safety, while Ex d relates to flameproof protection. The IIC gas group supports demanding gas environments, and T6 indicates a strict surface temperature class.
For Qatar projects, this marking helps consultants and safety teams check whether the rotary switch suits the site classification. The final selection must always match the hazardous-area study, electrical design, installation method, and project approval documents.
Many buyers use ATEX rotary switch, explosion proof rotary switch, flame proof rotary switch, intrinsically safe rotary switch, and hazardous area rotary switch together. However, each term can describe a different hazardous-area protection method or application.
| Term | Meaning |
|---|---|
| ATEX Rotary Switch | Rotary switch certified or selected for explosive atmosphere installations |
| Explosion Proof Rotary Switch | Rotary switch used in an Ex-rated hazardous-area system |
| Flame Proof Rotary Switch | Rotary switch using flameproof or Ex-rated protection |
| Intrinsically Safe Rotary Switch | Low-energy rotary switch circuit selected for approved Ex i systems |
| Hazardous Area Rotary Switch | Rotary switch used in classified industrial areas |
| Ex Brass Rotary Switch | Rotary switch with brass construction for Ex electrical applications |
| 2-Pole Rotary Switch | Rotary switch designed to switch two poles or circuit paths |
This difference matters in Qatar projects because consultants, EPC contractors, safety teams, and inspectors may ask for a specific protection method. Always confirm whether the project needs Ex d, Ex e, Ex i, IIC gas group, T6 temperature class, or a specific current and voltage rating.
Correct installation keeps the Ex Rotary Switch 0, 2-Pole, 16A, Max 660V AC safe and reliable. The installer must check the ATEX marking, voltage, current, pole arrangement, cable entry system, enclosure condition, grounding, operating position, and site approval before commissioning.
Certifications and markings help buyers choose the correct hazardous-area rotary switch. The final product must match the site zone, gas group, temperature class, current rating, voltage rating, IP protection, pole configuration, and project inspection requirement.
The product listing shows marking ATEX II 2G Eex ed IIC T6, along with 16A, max 660V AC, and IP56.
The Ex Rotary Switch 0, 2-Pole, 16A, Max 660V AC, IP56 gives industries a compact and practical hazardous-area rotary switching solution. It supports 2-pole switching, 16A load control, max 660V AC operation, IP56 protection, and ATEX II 2G Eex ed IIC T6 marking.
For Qatar projects, this rotary switch suits oil & gas, LNG, petrochemical, refinery, marine, port, utility, power, automation, factory, workshop, control panel, field station, and infrastructure applications. Its 2-pole design, 16A current rating, 660V AC max rating, IIC gas group, T6 temperature class, and Ex brass rotary switch construction make it useful for hazardous-area electrical control applications.
1. What is Ex Rotary Switch 0, 2-Pole, 16A used for?
It is used for rotary switching and local control in hazardous gas areas.
2. Is this suitable for Flame Proof Rotary Switch in Qatar projects?
Yes, it can suit Qatar hazardous-area projects when the ATEX marking, current rating, voltage rating, and site classification match the requirement.
3. What is the current rating?
The product name lists 16A.
4. What is the maximum voltage?
The product name lists max 660V AC.
5. What is the IP rating?
The product name lists IP56.
6. What is the ATEX marking?
The product name lists ATEX II 2G Eex ed IIC T6.
7. What is the product ID?
The listing shows Product ID 122412.
8. What are the product dimensions?
The listing shows 130 mm length, 135 mm width, and 115 mm height.
9. Where can it be used in Qatar?
It suits Doha, Ras Laffan, Mesaieed, Dukhan, Al Wakrah, Hamad Port, LNG facilities, oilfields, utilities, factories, and workshops.
10. Who supplies flame proof rotary switches globally?
Atex Hub supplies flame proof rotary switches across Qatar, UAE, Saudi Arabia, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide.
The Ex Rotary Switch 0, 2-Pole, 16A, Max 660V AC, IP56 gives industries a safe and practical rotary switching solution for hazardous gas areas. It supports 2-pole operation, 16A current, max 660V AC, IP56 protection, and ATEX II 2G Eex ed IIC T6 marking.
For buyers searching for Flame Proof Rotary Switch in Qatar, this product offers strong value for oil & gas, LNG, petrochemical, refinery, marine, port, utility, power, automation, factory, workshop, control panel, and infrastructure projects. Its IIC gas group, T6 temperature class, Ex brass rotary switch design, and compact size make it suitable for hazardous-area electrical control applications.
Atex Hub supplies Ex rotary switches and other hazardous-area rotary control products globally across Qatar, UAE, Saudi Arabia, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide, helping industries source safe and compliant Ex-rated switching solutions.