

If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The Exd Motor Starter – IECEx ATEX Hazardous Area Zone 1, 2 helps industries start, protect, and control electric motors in hazardous industrial areas. It supports motor control applications where explosive gases, dust, vibration, moisture, corrosion, and heavy-duty operating conditions can affect normal electrical equipment.
For companies searching for Flame Proof Motor Starter in Saudi, this product suits ATEX motor starter, explosion proof motor starter, flame proof motor starter, intrinsically safe motor starter, and hazardous area motor starter requirements. It works well in oil & gas plants, refineries, petrochemical units, chemical plants, marine areas, utilities, pump stations, compressor systems, manufacturing facilities, control panels, and industrial automation projects.
Atex Hub supplies flame proof motor starters globally across Saudi Arabia, UAE, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide, helping industries source safe and certified hazardous-area motor control products.
The Exd Motor Starter IECEx ATEX Hazardous Area Zone 1, 2 is an explosion proof motor control starter station designed for hazardous-area electric motors. It helps operators start motors safely, protect equipment from overload, control motor circuits, and manage industrial machinery in classified gas and dust locations.
This motor starter uses flameproof “db” protection and dust ignition protection by enclosure “tb”. It suits harsh industrial locations with moisture, dirt, dust, corrosion, and vibration. The motor starter supports hazardous-area applications in oil and gas, marine, petrochemical, chemical, petroleum, spray booth, and brewery environments.
The product belongs to the BQD Series and supports IECEx and ATEX certification. It also supports motor control configurations such as direct-on-line control and star-delta control, depending on the motor requirement and project design.
The Exd Motor Starter Zone 1, 2 gives site teams a rugged motor control solution for classified hazardous areas. It supports safe motor starting and protection in industrial locations where gas, vapour, combustible dust, humidity, corrosion, and vibration can damage ordinary motor starters.
The electrical configuration includes 380 / 400 V AC 50 / 60 Hz, IP66 protection, and key components such as MCB, AC contactor, thermal overload relay, indicator, and pushbutton.
The Exd Motor Starter IECEx ATEX Hazardous Area Zone 1, 2 helps industries start and protect motors safely in hazardous-area projects. It suits applications where standard motor starters cannot handle explosion protection, outdoor exposure, dust, corrosion, vibration, or heavy-duty motor control requirements.
| Specification | Details |
|---|---|
| Product Name | Exd Motor Starter – IECEx ATEX Hazardous Area Zone 1, 2 |
| Product Type | Explosion Proof / Flame Proof Motor Starter |
| Series | BQD Series |
| Application | Hazardous-area motor starting and protection |
| Protection Concept | Flameproof “db” |
| Dust Protection | Dust ignition protection by enclosure “tb” |
| Hazardous Area Suitability | Zone 1 and Zone 2 |
| Rated Voltage | 380 / 400 V AC, 50 / 60 Hz |
| Degree of Protection | IP66 |
| Main Components | MCB, AC contactor, thermal overload relay, indicator, pushbutton |
| Enclosure Material | Copper-free aluminium |
| Surface Finish | Powder-coated surface |
| Control Options | Direct-on-line control, star-delta control |
| IECEx Certificate | IECEx LCI 08.0010 |
| ATEX Certificate | LCIE 06 ATEX |
| IECEx Marking | Ex d IIB T6 |
| ATEX Gas Marking | Ex II 2 G Ex d IIB T6/T5 Gb |
| ATEX Dust Marking | Ex II 2 D Ex tb IIC T80°C/T95°C Db IP66 |
| Custom Options | Entry size, entry direction, enclosure material, thermal relay setting, circuit breaker rating, and motor power selection |
| Supplier | Atex Hub |
This motor starter supports IECEx LCI 08.0010, LCIE 06 ATEX, Ex d IIB T6, Ex II 2 G Ex d IIB T6/T5 Gb, and Ex II 2 D Ex tb IIC T80°C/T95°C Db IP66 marking.
The correct flame proof motor starter depends on the hazardous zone, gas group, dust protection, motor power, starter type, voltage, overload setting, circuit breaker rating, enclosure material, cable entry design, and certification requirement.
| Selection Point | What to Check |
|---|---|
| Motor Application | Confirm pump, compressor, fan, mixer, conveyor, skid, or machinery use |
| Hazardous Zone | Confirm Zone 1 or Zone 2 requirement |
| Gas Protection | Check whether Ex d IIB protection suits the site |
| Dust Protection | Confirm Ex tb dust protection requirement |
| Motor Power | Match starter selection with the connected motor kW |
| Control Type | Choose direct-on-line or star-delta control |
| Voltage | Confirm 380 / 400 V AC, 50 / 60 Hz supply |
| Overload Relay | Set the thermal relay according to motor full-load current |
| Circuit Breaker | Select correct circuit breaker current rating |
| Ingress Protection | Confirm IP66 requirement |
| Enclosure Material | Confirm copper-free aluminium or project-specific enclosure material |
| Compliance | Confirm IECEx / ATEX approvals, Ex marking, wiring, and site inspection requirements |
Flameproof db protection helps contain ignition inside the enclosure and prevents flame transmission to the surrounding hazardous atmosphere. This matters in motor starter applications because contactors, circuit breakers, overload relays, and control contacts can create electrical switching events during motor operation.
A flame proof motor starter helps industries control motors in hazardous gas areas without using ordinary open electrical devices. It gives operators safer motor control for pumps, compressors, fans, process skids, and plant machinery where explosive gases or vapours may exist.
Electric motors can overheat when they face overload, mechanical blockage, low voltage, phase imbalance, or continuous heavy running. A thermal overload relay helps protect the motor by reacting when current rises beyond the selected setting. This protection helps reduce motor damage and downtime.
The Exd Motor Starter Zone 1, 2 includes a thermal overload relay as part of its motor control components. This feature helps site teams protect motors used in pumps, fans, compressors, utility systems, process skids, and rotating equipment.
Industrial motor starters often face dust, water spray, humidity, washdown, and outdoor exposure. IP66 protection helps the enclosure resist dust entry and strong water jets. This makes the motor starter useful for refineries, marine areas, ports, chemical plants, utility systems, and outdoor process units.
When teams install the motor starter with correct Ex cable glands, proper seals, and correct grounding, the enclosure can support long-term operation in demanding hazardous-area environments.
Many buyers use ATEX motor starter, explosion proof motor starter, flame proof motor starter, intrinsically safe motor starter, and hazardous area motor starter together. However, each term can describe a different hazardous-area protection method or motor control system.
| Term | Meaning |
|---|---|
| ATEX Motor Starter | Motor starter selected for explosive atmosphere installations |
| Explosion Proof Motor Starter | Motor starter used as part of an Ex-rated hazardous-area system |
| Flame Proof Motor Starter | Motor starter using Ex d / db flameproof protection |
| Intrinsically Safe Motor Starter | Low-energy control circuit used with an approved Ex i design, usually not the power starter itself |
| Hazardous Area Motor Starter | Motor starter selected for classified gas or dust areas |
| Exd Motor Starter | Flameproof motor starter with Ex d protection |
| Star-Delta Motor Starter | Motor starter method used to reduce starting current for suitable motors |
| Direct-On-Line Motor Starter | Motor starter method that connects motor directly to supply through contactor and protection devices |
This difference matters in Saudi projects because consultants, EPC contractors, safety teams, and inspectors may ask for a specific protection method. Always confirm whether the project needs Ex d, db, tb, IIB gas group, dust protection, DOL control, star-delta control, or intrinsically safe control circuits.
Correct installation keeps the Exd Motor Starter IECEx ATEX Hazardous Area Zone 1, 2 safe and reliable. The installer must check the Ex marking, motor rating, overload setting, circuit breaker rating, cable entries, grounding, enclosure condition, and site approval before commissioning.
Certifications help buyers select the correct hazardous-area motor starter. The final product must match the site zone, gas group, dust group, motor power, starter type, current, voltage, enclosure material, cable entry system, ambient condition, and inspection standard.
The Exd Motor Starter Zone 1, 2 supports IECEx and ATEX hazardous-area certification. The certification details include IECEx LCI 08.0010 and LCIE 06 ATEX. The marking includes Ex d IIB T6, Ex II 2 G Ex d IIB T6/T5 Gb, and Ex II 2 D Ex tb IIC T80°C/T95°C Db IP66.
The Exd Motor Starter IECEx ATEX Hazardous Area Zone 1, 2 gives industries a rugged motor control solution for hazardous gas and dust areas. It supports flameproof db protection, dust ignition protection by enclosure, IP66 protection, DOL or star-delta control, thermal overload protection, MCB protection, contactor switching, indicator functions, and pushbutton control.
For Saudi projects, this motor starter suits oil & gas, petrochemical, refinery, chemical, marine, port, utility, power, automation, factory, workshop, pump station, compressor system, spray booth, brewery, control panel, and infrastructure applications. Its Ex d IIB gas protection, Ex tb dust protection, 380 / 400 V AC 50 / 60 Hz rating, copper-free aluminium enclosure, and IECEx / ATEX approvals make it useful for demanding hazardous-area motor control.
1. What is Exd Motor Starter IECEx ATEX Hazardous Area Zone 1, 2 used for?
It starts, protects, and controls motors in hazardous gas and dust areas, especially motors used in pumps, compressors, fans, skids, and industrial machinery.
2. Is this suitable for Flame Proof Motor Starter in Saudi projects?
Yes, it can suit Saudi hazardous-area projects when the zone, gas group, dust protection, motor power, voltage, and certification match the site requirement.
3. What hazardous zones does this motor starter support?
It supports hazardous-area motor control for Zone 1 and Zone 2 applications.
4. What rated voltage does it use?
The motor starter uses 380 / 400 V AC, 50 / 60 Hz rated voltage.
5. What IP rating does it offer?
The motor starter offers IP66 degree of protection.
6. What components does it include?
The motor starter includes MCB, AC contactor, thermal overload relay, indicator, and pushbutton components.
7. What control configurations can it support?
It can support direct-on-line control and star-delta control based on project design.
8. What enclosure material does it use?
The motor starter uses copper-free aluminium with a powder-coated surface.
9. Where can it be used in Saudi Arabia?
It suits Riyadh, Dammam, Jubail, Jeddah, Al Khobar, Yanbu, Ras Tanura, industrial cities, oilfields, refineries, ports, factories, utilities, and infrastructure sites.
10. Who supplies flame proof motor starters globally?
Atex Hub supplies flame proof motor starters across Saudi Arabia, UAE, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide.
The Exd Motor Starter IECEx ATEX Hazardous Area Zone 1, 2 gives industries a certified motor control solution for hazardous gas and dust environments. It supports flameproof db protection, dust ignition protection by enclosure, IP66 enclosure protection, direct-on-line control, star-delta control, MCB protection, contactor switching, thermal overload protection, indicator functions, and pushbutton operation.
For buyers searching for Flame Proof Motor Starter in Saudi, this product offers strong value for oil & gas, petrochemical, refinery, chemical, marine, port, utility, power, automation, factory, workshop, spray booth, brewery, pump station, compressor system, and infrastructure projects. Its Ex d IIB marking, Ex tb dust protection, 380 / 400 V AC 50 / 60 Hz rating, and IECEx / ATEX approvals make it suitable for demanding hazardous-area motor control applications.
Atex Hub supplies Exd Motor Starters and other hazardous-area motor starter solutions globally across Saudi Arabia, UAE, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide, helping industries source safe and compliant Ex-rated motor control products.