The Atex Single IR Flame Detector is a compact, cost-effective flame proof detector that provides fast, reliable flame detection in hazardous areas across the UAE. Tuned to a single infrared (IR) wavelength associated with hydrocarbon fires, it confirms a true flame while resisting common false alarms from hot equipment and sunlight. Its small footprint fits crowded skids and shelters in Dubai, Abu Dhabi, and Sharjah, and its rugged, sealed housing stands up to heat, dust, and saline air. If you’re looking for a dependable single spectrum flame detector, single ir flame detector, or a simpler alternative to multi-IR devices, this unit delivers solid performance with straightforward integration to your F&G or PLC system.
A Flame Proof Detector (Ex-rated flame detector) is a fire detection device certified for explosive atmospheres. It identifies flames by analysing optical energy from combustion and is enclosed so any internal fault cannot ignite the surrounding gas or dust. The Atex Single IR Flame Detector focuses on single-spectrum infrared sensing—a proven method for detecting hydrocarbon pool and spray fires quickly and economically. With ATEX/IECEx approvals, IP66/67 environmental sealing, and corrosion-resistant materials, it is engineered for the Gulf climate. Outputs such as 4–20 mA, alarm/fault relays, and optional RS-485/Modbus make it easy to drop into existing panels in Dubai, Abu Dhabi, and Sharjah without major rewiring.
Across Dubai, Abu Dhabi, and Sharjah, the Atex Single IR Flame Detector protects areas where fast confirmation matters but conditions are relatively stable: pump bays, small compressor enclosures, fuel day tanks, paint mix rooms, packaging lines, analyser shelters, and EX-rated warehousing. Single-IR technology is especially attractive where budgets are tight, coverage distances are moderate, and line-of-sight is clear. Its tuned IR band helps distinguish real hydrocarbon flames from background heat, supporting ESD trips, deluge/foam release, and alarm escalation with fewer nuisance activations. Maintenance teams appreciate the compact housing, clear status indication, and simple alignment.
Oil & Gas / Petrochem (UAE): Fuel handling skids, tank farm manifolds, separators, lube oil rooms.
Power & Utilities: Gas turbine auxiliaries, day tanks, boiler rooms, diesel generator enclosures.
Chemicals & Paints: Solvent stores, mixing rooms, spray booths, packaging with flammable vapours.
Marine & Ports (Dubai/Abu Dhabi): Jetty manifolds, bunkering stations, berths exposed to saline air.
Warehousing & Logistics (Sharjah): EX-classified drum stores, loading bays, and transfer points.
OEM Skids / Buildings: Analyzer shelters, HVAC plant rooms with fuel sources, compact machinery spaces.
Proven, affordable detection: Single spectrum infrared offers solid performance for hydrocarbon fires at a lower installed cost.
Hazardous-area certified: ATEX/IECEx with Ex d/Ex e options for Zone 1/2 (and Zone 21/22 variants where specified).
Built for the Gulf: IP66/67 sealing, marine-grade finishes, and optional heated optics handle heat, dust, and humidity.
Easy integration: Standard 4–20 mA, alarm/fault relays, optional RS-485/Modbus; simple commissioning on F&G/PLC.
Compact footprint: Fits tight panels and skids; adjustable bracket and sight marks support quick aiming and service.
Supported locally: Specification, spacing guidance, and documentation packs supplied by Atex Hub across the UAE.
| Parameter | Specification |
|---|---|
| Product Name | Atex Single IR Flame Detector |
| Detection Principle | Single-spectrum infrared (IR) with flame flicker verification |
| Certifications | ATEX, IECEx (gas/dust variants; model dependent) |
| Hazardous Area | Gas: Zone 1 / Zone 2; Dust: Zone 21 / Zone 22 (where applicable) |
| Protection Concept | Ex d (flameproof) and/or Ex e (increased safety), per model |
| Ingress Protection | IP66 / IP67 (IEC 60529) |
| Response Time | Seconds or sub-seconds; fuel & distance dependent |
| Field of View | Wide FOV; medium/long-range hydrocarbon fire detection (model dependent) |
| Outputs | 4–20 mA, Alarm/Fault relays; optional RS-485/Modbus |
| Supply Voltage | 18–32 VDC (typical) |
| Operating Temperature | −40 °C to +75 °C (typical model range) |
| Optics | Treated/optional heated window; automatic optical self-test |
| Housing | Coated aluminium or stainless steel (marine options) |
| Mounting | Adjustable bracket; alignment sight marks |
| Accessories | Sun shield, weather hood, IR test lamp, junction box kits |
| Documentation | Datasheet, GA/wiring drawings, test/inspection report, ATEX/IECEx certificates |
ATEX Directive 2014/34/EU – equipment for explosive atmospheres
IECEx Scheme – international certification for Ex equipment
EN 60079-0 – Explosive atmospheres: General requirements
EN 60079-1 – Flameproof enclosure “d”
EN 54-10 – Fire detection and alarm systems — Flame detectors (point type)
IEC 60529 – IP ratings (IP66/IP67)
1) When is a single IR detector a good choice for Dubai sites?
When targets are hydrocarbon fires, line-of-sight is clear, and you want reliable performance at lower cost versus multi-IR units.
2) Will it cope with Abu Dhabi offshore conditions?
Yes—ATEX/IECEx, IP66/67, marine-grade housings, and optional heated optics suit offshore modules and jetty manifolds.
3) What about dusty Sharjah warehouses?
Select the dust-certified variant (Zone 21/22) and maintain optics; routine cleaning keeps ranges consistent.
4) How does it connect to my F&G system?
Use the 4–20 mA current loop and alarm/fault relays; RS-485/Modbus is available for diagnostics and polling.
5) Any placement tips?
Provide clear sight to hazards, avoid reflective glare, angle slightly downward to reduce condensation, and use sun shields outdoors.
6) How often should I test the detector?
Follow your site plan—clean the window periodically and function-test with an approved IR test lamp to verify response and outputs.
7) Who supplies certificates and drawings in the UAE?
Atex Hub provides the full ATEX/IECEx certificate pack, GA/wiring drawings, inspection reports, and nameplate data for approvals.
The Atex Single IR Flame Detector offers fast, dependable flame confirmation for UAE sites that need simplicity, value, and compliance. From Dubai tank farms to Abu Dhabi process skids and Sharjah warehouses, it combines single-spectrum IR technology with Ex-certified housing, IP66/67 durability, and easy integration. With local support and documentation from Atex Hub, you can commission quickly, reduce nuisance trips, and protect people and assets with confidence.