The Explosion Proof ATEX Motor Starters Ex IIB AC1WD & ERSA Aluminium help industries start, protect, and control electric motors in hazardous gas and dust areas. These motor starters support motor control applications where explosive atmospheres, heavy-duty industrial use, and certified electrical protection matter.
For companies searching for Explosion Proof Motor Starter in UAE, this product suits ATEX motor starter, explosion proof motor starter, flame proof motor starter, intrinsically safe motor starter, and hazardous area motor starter requirements. It works well in oil & gas plants, refineries, petrochemical units, chemical plants, marine areas, ports, utilities, power plants, factories, workshops, pump stations, compressor systems, and industrial automation projects.
Atex Hub supplies explosion proof motor starters globally across UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide, helping industries source safe and certified motor control products for hazardous-area applications.
The Explosion Proof ATEX Motor Starters Ex IIB AC1WD & ERSA Aluminium are flameproof motor starter units designed for hazardous-area motor control. They help operators start and protect electric motors used in pumps, compressors, fans, conveyors, process machinery, skids, and industrial equipment.
These motor starters use a cast aluminium enclosure and support Group IIB hazardous-area applications. The range includes 3-pole explosion proof motor starters with thermal overload relay options. Depending on project requirements, the starter can include a thermal overload relay, fuses, contactor, or a combination of these components.
This product range suits difficult environments where normal motor starters cannot meet hazardous-area safety requirements. It supports motor protection, electrical isolation, circuit control, and safe operation in explosive atmospheres when the final configuration matches the site classification and electrical design.
The AC1WD & ERSA aluminium motor starter range gives industrial teams a certified motor control solution for hazardous gas and dust areas. It supports reliable motor starting and protection in locations where gas, vapour, combustible dust, moisture, heat, vibration, and heavy-duty electrical loads can affect normal equipment.
The technical configuration includes cast aluminium construction, IP65 protection, ATEX certificates for AC1WD and ERSA, Ex gas and dust markings, and electrical ratings up to 500 A and 1000 V depending on range selection.
The Explosion Proof ATEX Motor Starters Ex IIB AC1WD & ERSA Aluminium can support different motor protection and control needs. This flexibility helps panel builders, contractors, and maintenance teams select a starter according to motor size, protection level, switching method, and project electrical design.
A wide choice of enclosures, overload relays, contactors, and fuse options allows the motor starter to match different hazardous-area motor control applications.
The Explosion Proof ATEX Motor Starters Ex IIB AC1WD & ERSA Aluminium help industries start and protect motors safely in classified hazardous areas. They suit applications where standard motor starters cannot meet explosion protection, environmental durability, and motor safety requirements.
| Specification | Details |
|---|---|
| Product Name | Explosion Proof ATEX Motor Starters Ex IIB AC1WD & ERSA Aluminium |
| Product Type | Explosion Proof / Flame Proof Motor Starter |
| Product Ranges | AC1WD & ERSA |
| Motor Starter Type | 3-pole motor starter |
| Protection Concept | Ex db / Ex d flameproof protection |
| Gas Group | IIB |
| Dust Protection | Ex tb IIIC |
| Enclosure Material | Cast aluminium |
| IP Rating | IP65 according to EN/IEC 60529 |
| Temperature Range | -20°C to +40°C, +50°C, or +60°C |
| AC1WD Certificate | INERIS 03ATEX0145 |
| ERSA Certificate | INERIS 04ATEX0009X |
| General Marking | II 2 GD |
| AC1WD Marking | Ex db IIB T6 Gb, Ex tb IIIC T85°C Db |
| ERSA Marking | Ex d IIB T6…T4 Gb, Ex tb IIIC T85°C…135°C |
| AC1WD Electrical Rating Option 1 | Imax = 65 A, Umax = 500 V |
| AC1WD Electrical Rating Option 2 | Imax = 220 A, Umax = 750 V |
| ERSA Electrical Rating | Imax = 500 A, Umax = 1000 V |
| Push Button Head Endurance | 5 million operations |
| Contact Block Endurance | 1 million operations |
| Surface Treatment | Painted RAL 7032 |
| Supplier | Atex Hub |
The AC1WD range supports electrical ratings up to 65 A / 500 V and 220 A / 750 V, while the ERSA range supports up to 500 A / 1000 V. The motor starters use cast aluminium construction, IP65 protection, and ATEX flameproof protection for hazardous-area applications.
The correct explosion proof motor starter depends on the hazardous zone, gas group, dust group, motor rating, starter type, overload protection, fuse requirement, contactor requirement, enclosure material, IP rating, temperature range, and certification requirement.
| Selection Point | What to Check |
|---|---|
| Motor Control Need | Confirm pump, compressor, fan, conveyor, skid, or machinery application |
| Gas Group | Check whether IIB protection suits the hazardous area |
| Dust Protection | Confirm whether Ex tb IIIC dust protection applies |
| Motor Rating | Match current and voltage with motor size |
| Starter Version | Select overload-only, overload with fuses, or overload with contactor and fuses |
| Current Rating | Choose AC1WD or ERSA based on load current |
| Voltage Rating | Confirm 500 V, 750 V, or 1000 V requirement |
| Enclosure Material | Choose cast aluminium for rugged hazardous-area use |
| Temperature Range | Confirm -20°C to +40°C, +50°C, or +60°C suitability |
| IP Rating | Confirm IP65 protection requirement |
| Compliance | Confirm ATEX certificate, Ex marking, wiring, and site approval before procurement |
Electric motors can overheat when they face overload, phase imbalance, mechanical blockage, or continuous heavy operation. Thermal overload protection helps reduce motor damage by reacting to excessive current conditions. This protection becomes very important in hazardous areas because overheated motors and electrical faults can create serious safety risks.
The AC1WD & ERSA motor starter range can include thermal overload relays. This helps site teams protect motors used in pumps, compressors, fans, process equipment, and packaged systems. When the project needs extra protection, the starter can also include fuses and contactor-based switching.
Aluminium gives the motor starter a strong but manageable enclosure for industrial environments. It helps reduce weight compared with heavier metal enclosures, while still supporting rugged hazardous-area use. This makes aluminium motor starters useful for plant rooms, skid packages, outdoor panels, process units, ports, and industrial installations.
The cast aluminium enclosure also supports flameproof protection and allows the starter to operate in difficult environments. With proper installation, certified cable entries, grounding, and routine inspection, the motor starter can support long-term motor control in hazardous gas and dust areas.
Many buyers use ATEX motor starter, explosion proof motor starter, flame proof motor starter, intrinsically safe motor starter, and hazardous area motor starter together. However, each term can describe a different hazardous-area protection method or control system.
| Term | Meaning |
|---|---|
| ATEX Motor Starter | Motor starter selected for explosive atmosphere installations |
| Explosion Proof Motor Starter | Motor starter used inside an Ex-rated hazardous-area system |
| Flame Proof Motor Starter | Motor starter using Ex d / Ex db flameproof protection |
| Intrinsically Safe Motor Starter | Low-energy control circuit used with approved Ex i design, usually not the power starter itself |
| Hazardous Area Motor Starter | Motor starter selected for classified gas or dust areas |
| Ex IIB Motor Starter | Motor starter selected for IIB gas group hazardous areas |
| Ex tb Motor Starter | Motor starter with dust protection for combustible dust environments |
This difference matters in UAE projects because consultants, EPC contractors, safety teams, and inspectors may ask for a specific protection method. Always confirm whether the project needs Ex d, Ex db, Ex tb, IIB gas group, IIIC dust protection, overload protection, fused protection, or contactor control.
Correct installation keeps the Explosion Proof ATEX Motor Starters Ex IIB AC1WD & ERSA Aluminium safe and reliable. The installer must check the certificate, Ex marking, motor rating, overload relay setting, fuse rating, contactor configuration, cable entry system, grounding, enclosure condition, and site approval before commissioning.
Certifications help buyers choose the correct hazardous-area motor starter. The final product must match the site zone, gas group, dust group, motor rating, current, voltage, protection device, cable entry arrangement, ambient temperature, and inspection standard.
The AC1WD & ERSA aluminium motor starters include ATEX approvals for hazardous-area use. The AC1WD range carries INERIS 03ATEX0145, and the ERSA range carries INERIS 04ATEX0009X. The product marking includes II 2 GD, Ex db IIB T6 Gb, Ex tb IIIC T85°C Db, and ERSA configurations with Ex d IIB T6…T4 Gb and Ex tb IIIC T85°C…135°C.
The Explosion Proof ATEX Motor Starters Ex IIB AC1WD & ERSA Aluminium give industries a certified motor control solution for hazardous gas and dust areas. They support thermal overload protection, optional fuse protection, optional contactor control, cast aluminium construction, IP65 protection, and Ex IIB flameproof applications.
For UAE projects, this motor starter range suits oil & gas, petrochemical, refinery, chemical, marine, port, utility, power, automation, factory, workshop, pump station, compressor system, control panel, field station, and infrastructure applications. Its Ex db IIB gas protection, Ex tb IIIC dust protection, AC1WD and ERSA rating options, thermal overload relay support, and cast aluminium enclosure make it useful for demanding hazardous-area motor control.
1. What are Explosion Proof ATEX Motor Starters Ex IIB AC1WD & ERSA Aluminium used for?
They control and protect electric motors in hazardous gas and dust areas, especially in pumps, compressors, fans, skids, and industrial machinery.
2. Is this suitable for Explosion Proof Motor Starter in UAE projects?
Yes, it can suit UAE hazardous-area projects when the gas group, dust marking, motor rating, voltage, current, and site classification match the requirement.
3. What material does the enclosure use?
The motor starter uses cast aluminium construction.
4. What IP rating does it offer?
The motor starter offers IP65 protection according to EN/IEC 60529.
5. What protection marking does AC1WD carry?
AC1WD carries Ex db IIB T6 Gb and Ex tb IIIC T85°C Db markings.
6. What protection marking does ERSA carry?
ERSA configurations carry Ex d IIB T6…T4 Gb and Ex tb IIIC T85°C…135°C markings.
7. What current and voltage ratings are available?
AC1WD supports up to 65 A / 500 V or 220 A / 750 V, while ERSA supports up to 500 A / 1000 V.
8. Does this motor starter include overload protection?
Yes, the range supports configurations with thermal overload relay, with optional fuses and contactor arrangements.
9. Where can it be used in UAE?
It suits Dubai, Abu Dhabi, Sharjah, Ajman, Fujairah, Ras Al Khaimah, Umm Al Quwain, Jebel Ali, KIZAD, Hamriyah Free Zone, DIP, Dubai South, ports, utilities, factories, oilfields, and infrastructure sites.
10. Who supplies explosion proof motor starters globally?
Atex Hub supplies explosion proof motor starters across UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide.
The Explosion Proof ATEX Motor Starters Ex IIB AC1WD & ERSA Aluminium give industries a certified motor control solution for hazardous gas and dust areas. They support motor starting, overload protection, fuse protection, contactor control, flameproof enclosure protection, and reliable operation in demanding industrial environments.
For buyers searching for Explosion Proof Motor Starter in UAE, this product offers strong value for oil & gas, petrochemical, refinery, chemical, marine, port, utility, power, automation, factory, workshop, pump station, compressor system, and infrastructure projects. Its cast aluminium enclosure, Ex db / Ex d IIB gas protection, Ex tb IIIC dust protection, IP65 rating, and high current and voltage options make it suitable for hazardous-area motor control applications.
Atex Hub supplies AC1WD & ERSA aluminium motor starters and other hazardous-area motor starter solutions globally across UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide, helping industries source safe and compliant Ex-rated motor control products.