Explosion Proof Distribution Board in Sharjah | IS Distribution Board
The ATEX Heating Circuit Distribution Boards with Residual Current Circuit Breaker with Overcurrent Release Series 8264/5 help distribute and protect heating circuits in hazardous areas. These boards support heat tracing, process heating, lighting circuits, utility power, field electrical loads, and industrial distribution systems in explosive gas and dust locations.
For companies searching for Explosion Proof Distribution Board in Sharjah, this product suits ATEX distribution boards, explosion proof distribution boards, flame proof distribution boards, hazardous area distribution boards, and intrinsically safe distribution boards. It works well in oil & gas plants, refineries, petrochemical sites, tank farms, chemical plants, marine areas, power stations, utilities, and industrial infrastructure projects.
Atex Hub supplies ATEX heating circuit distribution boards globally across UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide, supporting certified hazardous area electrical distribution requirements.
What Is an ATEX Heating Circuit Distribution Board Series 8264/5?
An ATEX heating circuit distribution board is a certified electrical distribution system for hazardous areas. It helps distribute power to heating circuits, heat tracing lines, lighting circuits, field equipment, and process electrical loads.
The Series 8264/5 board uses an Ex d aluminium enclosure system and supports hazardous-area circuit protection. It includes a load and motor switch and 24 residual current circuit breakers with overcurrent release. This setup helps protect heating circuits from leakage current, overload, and short-circuit faults.
This distribution board suits sites where normal electrical panels cannot meet explosion protection requirements. It works well in Sharjah Industrial Area, Hamriyah Free Zone, SAIF Zone, ports, warehouses, factories, utilities, chemical plants, oil & gas facilities, and infrastructure projects.
The product data lists Product Type 8264/5-ExV-02-24H16C1N-D, 230–400 V AC, 100 A rated operational current, aluminium enclosure material, 1 load and motor switch, and 24 residual current circuit breakers 1-pole 16 A+N/30 mA/C.
Key Features of Explosion Proof Distribution Boards
The ATEX Heating Circuit Distribution Board Series 8264/5 gives project teams a certified solution for heating and lighting circuit distribution in hazardous areas. It helps teams manage multiple circuits from one Ex-rated distribution board.
- Ideal for Explosion Proof Distribution Board in Sharjah
- Suitable for ATEX Distribution Boards in hazardous areas
- Supports Flame Proof Distribution Boards search requirements where Ex d protection is needed
- Works as a Hazardous Area Distribution Board for heating and lighting circuits
- Can support Intrinsically Safe Distribution Boards project needs when connected circuits follow approved Ex i design rules
- Uses an Ex d enclosure with aluminium material
- Supports 230–400 V AC operation
- Provides 100 A rated operational current
- Includes 1 load and motor switch
- Includes 24 residual current circuit breakers with overcurrent release
- Uses 1-pole 16 A + N / 30 mA / C circuit protection
- Supports standard variants for faster project supply
- Suits demanding industrial and outdoor hazardous areas
The Series 8264/-ExV range includes Ex d enclosures, miniature circuit breakers with tripping characteristic C, residual current circuit breakers with overcurrent release, and standard variants for short delivery times.
Applications of ATEX Heating Circuit Distribution Boards
The Series 8264/5 heating circuit distribution board helps distribute power and protect circuits in hazardous industrial sites. It suits heating, lighting, heat tracing, utility, and field power applications.
- Oil & Gas Facilities – Teams use the board for heat tracing, heating circuits, utility circuits, and field electrical distribution.
- Refineries – It supports heating circuits in process units, tank farms, pipelines, loading areas, and utility sections.
- Petrochemical Plants – It helps protect heating and lighting circuits where gas, vapour, chemicals, and dust may exist.
- Chemical Processing Units – It suits areas with chemical exposure, moisture, process vapour, and hazardous electrical loads.
- Tank Farms – It supports heat tracing for tanks, pipelines, valves, manifolds, and instrumentation lines.
- Marine and Port Areas – It works well in outdoor, coastal, humid, and industrial environments.
- Power Plants – It supports heating circuits, auxiliary systems, lighting distribution, and utility loads.
- Industrial Automation Projects – It supports field power distribution for control panels, instruments, process skids, and plant equipment.
- Hazardous Area Lighting Systems – It helps distribute lighting circuits in classified industrial areas.
- Sharjah Industrial Projects – It suits Sharjah Industrial Area, SAIF Zone, Hamriyah Free Zone, Khalid Port, Hamriyah Port, warehouses, factories, utilities, workshops, and infrastructure work.
Technical Specifications
| Specification | Details |
|---|
| Product Name | ATEX Heating Circuit Distribution Boards with Residual Current Circuit Breaker with Overcurrent Release Series 8264/5 |
| Product Type | 8264/5-ExV-02-24H16C1N-D |
| Board Type | CUBEx Lighting and Heating Circuit Distribution Board |
| Enclosure Material | Aluminium |
| Rated Voltage | 230–400 V AC |
| Rated Current | 100 A |
| Built-in Unit 1 | 1 x Load and Motor Switch |
| Built-in Unit 2 | 24 x RCCB with overcurrent release, 1-pole 16 A+N / 30 mA / C |
| Ambient Temperature | -20°C to +40°C |
| Certificates | ATEX, IECEx, PESO, NEPSI, KGS, ITRI, UL, ULB |
| Supplier | Atex Hub |
The product data confirms -20°C to +40°C ambient temperature, 230–400 V AC, 100 A rated operational current, ATEX and IECEx certificates, aluminium enclosure material, and the built-in switch and circuit breaker arrangement.
Hazardous Area Selection Guide
The correct explosion proof distribution board depends on the site zone, load type, heating circuit quantity, voltage, current, circuit protection, enclosure material, ambient temperature, and project certification requirement.
| Selection Point | What to Check |
|---|
| Load Type | Confirm heating circuit, lighting circuit, or mixed distribution requirement |
| Voltage | Check whether the project matches 230–400 V AC |
| Current | Confirm total connected load against the 100 A board rating |
| Circuit Quantity | Check whether 24 protected circuits suit the project |
| Protection Device | Confirm RCCB with overcurrent release requirement |
| Trip Characteristic | Confirm C curve suitability for the connected loads |
| Ambient Temperature | Check site temperature against -20°C to +40°C |
| Enclosure Type | Select Ex d aluminium enclosure where the project requires flameproof protection |
| Certificate | Confirm ATEX, IECEx, or project-required approval |
| Installation Area | Check gas, dust, outdoor, marine, chemical, and industrial exposure |
Explosion Proof Distribution Board vs Intrinsically Safe Distribution Board
Many buyers use ATEX distribution board, explosion proof distribution board, flame proof distribution board, hazardous area distribution board, and intrinsically safe distribution board together. However, each term can describe a different safety concept.
| Term | Meaning |
|---|
| ATEX Distribution Board | Certified board for electrical distribution in explosive atmospheres |
| Explosion Proof Distribution Board | Common term for Ex-certified distribution boards |
| Flame Proof Distribution Board | Often used when the board uses Ex d flameproof enclosure protection |
| Hazardous Area Distribution Board | General term for distribution boards used in classified industrial areas |
| Intrinsically Safe Distribution Board | Used for low-energy Ex i circuits when the full design follows IS rules |
This difference matters in Sharjah and UAE projects because consultants, EPC contractors, and safety teams may ask for a specific protection method. Always confirm the final Ex marking, certificate, circuit protection, cable entries, and area classification before ordering.
Certifications, Standards & Compliance
Certifications help buyers select the right hazardous-area distribution board. The final board must match the project’s area classification, voltage, current, circuit protection, enclosure type, cable entries, ambient temperature, and inspection rules.
This Series 8264/5 board lists certificates including ATEX (DEK), IECEx (DEK), Canada / USA (UL), Brazil (ULB), China (NEPSI), India (PESO), Korea (KGS), and Taiwan (ITRI).
- ATEX Certification – Supports European hazardous area equipment compliance.
- IECEx Certification – Supports international certification for equipment used in explosive atmospheres.
- Residual Current Protection – Helps detect earth leakage current and improve circuit safety.
- Overcurrent Protection – Helps protect circuits from overload and short-circuit faults.
- Ex d Enclosure Protection – Supports flameproof enclosure protection where the project requires Ex d distribution equipment.
- Project Compliance Check – Always confirm Ex certificate, voltage, current, circuit breaker rating, cable gland system, ambient temperature, and hazardous area classification.
Installation & Usage Notes
Correct installation keeps the ATEX heating circuit distribution board safe and reliable. The installer must check the certificate, board rating, circuit arrangement, cable entries, protection devices, grounding, labels, and enclosure condition before energising the system.
- Select the correct explosion proof distribution board based on heating and lighting circuit load.
- Confirm the 230–400 V AC supply requirement.
- Check the connected load against the 100 A rating.
- Use certified Ex cable glands, stopping plugs, reducers, adaptors, and locknuts.
- Label each heating or lighting circuit clearly.
- Keep wiring neat and avoid overcrowding.
- Confirm residual current and overcurrent protection before commissioning.
- Keep enclosure sealing surfaces clean.
- Maintain required hazardous-area protection.
- Inspect circuit breakers, switches, terminals, cable glands, labels, seals, and enclosure condition during maintenance.
Why Choose This Hazardous Area Distribution Board
The ATEX Heating Circuit Distribution Boards Series 8264/5 give industries a strong solution for hazardous-area heating and lighting circuit protection. The board combines Ex d enclosure protection, circuit distribution, residual current protection, overcurrent protection, and a load and motor switch.
For Sharjah projects, this distribution board suits oil & gas, petrochemical, refinery, chemical, marine, power, utilities, tank farms, heat tracing systems, warehouses, and industrial infrastructure applications. Its 230–400 V AC rating, 100 A rated operational current, 24 residual current circuit breakers, aluminium Ex d enclosure, and ATEX / IECEx certification make it useful for demanding hazardous-area installations.
- Ideal for Explosion Proof Distribution Board in Sharjah
- Suitable for ATEX Distribution Boards
- Supports Flame Proof Distribution Boards project requirements
- Works as a Hazardous Area Distribution Board
- Supports heating and lighting circuit distribution
- Includes residual current protection with overcurrent release
- Includes a load and motor switch
- Suitable for Sharjah and UAE industrial projects
- Supplied globally by Atex Hub
Frequently Asked Questions
1. What is an ATEX heating circuit distribution board used for?
It distributes and protects power for heating circuits, heat tracing lines, lighting circuits, and field electrical loads in hazardous areas.
2. Is this suitable for Explosion Proof Distribution Board in Sharjah projects?
Yes, it suits Sharjah hazardous-area projects when the voltage, current, certificate, and site classification match the requirement.
3. What is the operating voltage?
The listed rated operational voltage is 230–400 V AC.
4. What is the rated operational current?
The listed rated operational current is 100 A.
5. What enclosure material does it use?
It uses an aluminium enclosure.
6. What protection devices are included?
The configuration includes 24 residual current circuit breakers with overcurrent release, 1-pole 16 A+N / 30 mA / C.
7. Does it include a switch?
Yes, it includes 1 load and motor switch.
8. Can this board support heat tracing systems?
Yes, it suits heating circuit and heat tracing distribution in hazardous industrial areas.
9. Where can it be used in Sharjah?
It suits Sharjah Industrial Area, SAIF Zone, Hamriyah Free Zone, ports, warehouses, factories, utilities, workshops, and infrastructure sites.
10. Who supplies ATEX heating circuit distribution boards globally?
Atex Hub supplies ATEX heating circuit distribution boards across UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide.
Conclusion
The ATEX Heating Circuit Distribution Boards with Residual Current Circuit Breaker with Overcurrent Release Series 8264/5 give industries a safe and practical way to distribute power for heating and lighting circuits in hazardous areas. They support heat tracing systems, process heating, field electrical loads, and utility circuits in explosive gas and dust environments.
For buyers searching for Explosion Proof Distribution Board in Sharjah, this product offers strong value for oil & gas, petrochemical, refinery, marine, chemical, power, tank farm, utility, warehouse, and infrastructure projects. Its aluminium Ex d enclosure, 230–400 V AC rating, 100 A rated operational current, 24 residual current circuit breakers, and ATEX / IECEx certification make it suitable for demanding hazardous-area installations.
Atex Hub supplies ATEX Heating Circuit Distribution Boards Series 8264/5 globally across UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide, helping industries source compliant hazardous-area distribution board solutions.