If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The Atex Horizontal Flow Centrifugal Turret gives you safe, steady ventilation in places where flammable gas or dust may be present. Built around an Ex-rated motor and a centrifugal impeller, it moves air efficiently while controlling ignition risks at every interface. Unlike vertical roof units, this turret discharges horizontally, so you can direct exhaust away from sensitive air intakes, walkways, or neighbouring roofs—handy on tight UAE sites. A weather-proof body, corrosion-resistant hardware, and IP-rated entries keep performance reliable in the heat, dust, and salt-spray common across Dubai, Sharjah, and Abu Dhabi. If you need compliant extraction that installs fast and passes audits, choose the Ex Proof Turret in UAE, available locally from Atex Hub.
An Ex proof turret is a powered exhaust that removes flammable vapours, fumes, and fine dusts from rooms or process houses without becoming an ignition source. The Atex Horizontal Flow Centrifugal Turret pairs a pressure-capable centrifugal wheel with an ATEX/IECEx motor inside a weather cowl and side outlet. All hot surfaces, electrical parts, and interfaces are controlled to Ex rules, while Ex-compatible cable glands and sealing keep the enclosure tight. Because it throws air sideways, you can align discharge with ductwork, screens, or stack extensions—great for rooftops with height limits or where vertical plumes are restricted. In the UAE, where extremes of temperature, UV, airborne dust, and coastal air can punish ordinary fans, this turret’s build quality keeps airflow stable day after day.
Hydrogen extraction in battery-charging rooms and UPS spaces, with low-speed run and alarm-driven boost.
VOC/solvent removal in paint booths, mixing rooms, and cleaning areas to keep atmospheres below LEL.
Dust control around powder tipping, weighing, and blending where fine particulates are present.
Negative-pressure hold for analyser shelters, chemical dosing huts, and process skids.
Turnaround/hot-work support, providing temporary high-rate extraction for confined-space jobs.
Oil & Gas / Petrochemicals: Analyzer houses, tank farm cabinets, lube-oil rooms, solvent sheds.
Marine & Ports: Pump rooms, paint shops, dockside stores exposed to spray and salt.
Utilities & Water: Chlorination rooms and chemical dosing kiosks needing constant fume removal.
Food, Pharma & Chemical: Powder rooms and solvent prep areas requiring washable, sealed equipment.
Battery Rooms & Workshops: Forklift/UPS charging zones and maintenance bays in classified areas.
Choose the Atex Horizontal Flow Centrifugal Turret for safety, airflow pressure, and long service life. The centrifugal impeller handles duct losses and filters better than typical axial units, while noise stays manageable. Housings and fasteners are specified for UV, dust, and coastal corrosion, and motors are offered for common UAE voltages and VFD control. Installation is quick with standard curbs or plinths, Ex glands, and simple wiring. With Atex Hub support, you’ll match the duty point (m³/h @ Pa), Ex code, and controls to your process—so commissioning is faster and audits are smoother across Dubai, Sharjah, and Abu Dhabi.
| Item | Specification |
|---|---|
| Model | Atex Horizontal Flow Centrifugal Turret |
| Airflow Range | Approx. 1,000 – 18,000 m³/h (size & duty dependent) |
| Static Pressure | Up to 700–800 Pa (model dependent) |
| Protection Concept | ATEX/IECEx aligned; Ex gas/dust motor options (final Ex code on nameplate) |
| Motor Options | 2-/4-pole IE2/IE3, 50/60 Hz, 230/400/690 V AC (variant dependent) |
| Discharge Direction | Horizontal side outlet; cowl with weather lip / bird & ingress guard |
| Materials | Powder-coated steel or 316 stainless steel cowl; aluminium/PP anti-spark impeller |
| Ingress Protection | Turret/entries IP55–IP66 (installation dependent) |
| Operating Temperature | −20 °C to +55 °C continuous (higher by request & Ex class) |
| Mounting | Roof curb / flange plate; wall plinth option; vibration pads |
| Controls | DOL / Star-Delta; VFD with Ex-rated motor (verify compatibility), airflow switch option |
| Noise (Free Field) | 58–76 dB(A) @ 3 m typical (size & duty dependent) |
| Duct Interfaces | Round/rectangular adapters; backdraft damper / non-return options |
| Cable Entries | Metric/NPT Ex glands; internal earth points |
| Compliance | ATEX/IECEx, IEC 60079 explosive atmospheres; IEC 60529 IP; ISO 5801 performance test |
| Maintenance | Access panel for cleaning; sealed or grease-for-life bearings (model dependent) |
1) Why choose a horizontal flow turret?
It lets you aim the exhaust away from nearby intakes or walkways, reducing re-entrainment on crowded roofs.
2) Can I use a VFD?
Yes—when paired with a VFD-ready Ex motor and correct cabling/filters. Ideal for night-setback and boost modes.
3) How do I size the unit?
Share room volume, target ACH, contaminant type, and duct losses. We’ll select a duty point (m³/h @ Pa) that meets process and code needs.
4) Is it suitable for coastal Abu Dhabi and Dubai?
Yes—specify 316 SS, marine coatings, and IP66 entries for salt-spray environments.
5) What about hydrogen in battery rooms?
Use continuous low-speed extraction with alarm-driven boost, linked to hydrogen detectors and F&G logic.
6) What maintenance is needed?
Clean the cowl/outlet and impeller, check gland torque and fixings, and verify airflow switch or DP set-points during PM.
7) Can it be wall-mounted?
Roof mounting is standard, but wall plinth options exist. Confirm discharge direction, weather protection, and airflow path before selection.
For safe, dependable extraction in hazardous areas, the Atex Horizontal Flow Centrifugal Turret brings the pressure, durability, and control you need. Engineered for UAE conditions and supported locally by Atex Hub, it simplifies specification, speeds installation, and keeps air quality under control across Dubai, Sharjah, and Abu Dhabi. When ventilation is mission-critical, choose the Ex Proof Turret in UAE that’s built for the job.