The ATEX Stainless Steel Terminal & Junction Box Ex e protects terminals, cable connections, instrument loops, field wiring, control circuits, lighting connections, and junction points in hazardous area installations. It provides a compact AISI 316L stainless steel enclosure for industrial sites where explosive gas, combustible dust, moisture, corrosion, chemicals, impact, and outdoor exposure can affect electrical safety.
For companies looking for Ex Proof Terminal Box in Sharjah, this product offers a strong solution for ATEX terminal boxes, explosion proof terminal boxes, hazardous area enclosures, intrinsically safe enclosures, flame proof terminal boxes, Ex proof enclosures, and IS terminal boxes. It supports safe cable termination and terminal protection in oil & gas, refinery, petrochemical, marine, chemical, power, automation, logistics, and industrial infrastructure projects.
Atex Hub supplies ATEX Stainless Steel Terminal & Junction Boxes Ex e globally across UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide, helping industries source certified hazardous area terminal box solutions.
An ATEX Stainless Steel Terminal & Junction Box Ex e is a certified hazardous area enclosure used to house electrical terminals and junction wiring in explosive atmospheres. It supports Ex e / Ex eb increased safety protection, where the design reduces ignition risk through safe terminal spacing, insulation, enclosure protection, mechanical strength, and controlled temperature rise.
This terminal box is made for hazardous gas and dust locations. It can support Zone 1, Zone 2, Zone 21, and Zone 22 installations when the final marking and site classification match the project requirement. It also supports Ex tb dust protection for combustible dust areas, making it suitable for mixed gas and dust industrial environments.
The compact stainless steel construction makes it useful where corrosion resistance is important. In Sharjah and the wider UAE, stainless steel terminal boxes are commonly selected for industrial zones, marine areas, chemical plants, oil and gas facilities, and outdoor process locations.
Product Highlights:
The ATEX Stainless Steel Terminal & Junction Box Ex e helps protect wiring and terminal connections in hazardous area projects. It is suitable for environments where flammable gases, vapours, combustible dust, humidity, salt air, corrosive chemicals, and outdoor exposure may affect electrical components.
Its stainless steel body is useful for Sharjah, Dubai, Abu Dhabi, Ajman, Fujairah, Ras Al Khaimah, Umm Al Quwain, and wider UAE industrial facilities. It supports reliable operation in demanding sites such as ports, factories, process plants, free zones, refineries, and utility areas.
The enclosure is listed with a fully detachable cover, stainless steel A4 cover screws, silicone cover seal, IP66, and IK09 / IK10 shock resistance.
The ATEX Stainless Steel Terminal & Junction Box Ex e protects terminal wiring and cable connections in hazardous locations. It supports safe cable management, field wiring, junction protection, and instrument loop termination in industrial areas where certified Ex equipment is required.
Industries use these terminal boxes across UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide. In Sharjah, they support industrial zones, ports, marine facilities, process plants, warehouses, utilities, factories, workshops, and infrastructure projects.
| Specification | Details |
|---|---|
| Product Name | ATEX Stainless Steel Terminal & Junction Box Ex e |
| Product Category | ATEX Terminal Box / Stainless Steel Hazardous Area Enclosure |
| Product Type | Ex e Stainless Steel Terminal & Junction Box |
| Main Protection Type | Ex eb Increased Safety |
| Dust Protection | Ex tb IIIC Dust Protection |
| Gas Area Suitability | Zone 1 and Zone 2 |
| Dust Area Suitability | Zone 21 and Zone 22 |
| ATEX Marking | II 2 GD |
| Gas Marking | Ex eb IIC T Gb* |
| Dust Marking | Ex tb IIIC T Db |
| Temperature Marking | T6 / T80°C at Ta +40°C; T4 / T130°C at Ta +60°C |
| EU-Type Examination Certificate | CML 20 ATEX 3156X |
| IECEx Approval | IECEx CML 20.0094X |
| UKCA Approval | CML 21 UKEX 3892X |
| Operating Voltage | 352 V AC / DC max. for ATEX / IECEx |
| Cover Type | Fully detachable cover |
| Cover Fixing | A4 / V4A stainless steel combination pozi drive and slotted screws |
| Screw Size / Quantity | M6 / 4 screws |
| Tightening Torque | 3 Nm to 3.5 Nm |
| Cover Seal | Silicone |
| Degree of Protection | IP66 |
| Cable Entry Type | Direct through body |
| Cable Entries | 2 x M16 bottom face, 1 x M16 left side, 1 x M16 right side |
| Cable Gland Clamping Range | 4 mm to 8 mm |
| Terminal Assembly | 6 x 2.5 mm² terminals + 2 x 2.5 mm² PE terminals |
| Terminal Rail Orientation | Vertical rail |
| Material | 1.5 mm AISI 316L / 1.4404 stainless steel |
| Finish | Brushed stainless steel |
| Approximate Mass | 0.7 kg |
| Shock Resistance | IK09 / IK10 |
| External Dimensions | 96 mm x 110 mm x 87 mm |
| Internal Dimensions | 72 mm x 86 mm x 66 mm |
| Mounting | 4 screws |
| Grounding | M6 internal / external brass nickel-plated grounding bolt |
| Ambient Temperature | -40°C to +60°C |
| Supplier | Atex Hub |
| Supply Region | UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, Worldwide |
This terminal and junction box supports a compact wiring arrangement for field circuits, control wiring, instrument loops, and lighting connections. The cable entry layout supports wiring access from three faces while keeping the enclosure compact.
| Configuration Area | Details |
|---|---|
| Bottom Face Cable Entries | 2 x M16 cable glands |
| Left Side Cable Entry | 1 x M16 cable gland |
| Right Side Cable Entry | 1 x M16 cable gland |
| Cable Gland Type | Plastic / polyamide cable glands depending on final configuration |
| Clamping Range | 4 mm to 8 mm |
| Terminal Type | 6 x 2.5 mm² terminals |
| Earth Terminals | 2 x 2.5 mm² PE terminals |
| Rail Orientation | Vertical rail |
The terminal assembly includes 6 x MUT 2.5 terminals and 2 x MUT 2.5 PE terminals, with 2.5 mm² terminal capacity and one vertical rail.
The correct Ex proof terminal box depends on the site classification, terminal quantity, cable size, cable entry plan, gas group, dust group, IP rating, and temperature class. The final assembly must match the site’s hazardous area requirement before installation.
| Selection Point | What to Check |
|---|---|
| Gas Zone | Confirm whether the site requires Zone 1 or Zone 2 suitability |
| Dust Zone | Confirm whether the project needs Zone 21 or Zone 22 suitability |
| Protection Type | Select Ex eb, Ex i, Ex tb, or mixed protection based on wiring design |
| Gas Group | Confirm IIC requirement for gas hazardous areas |
| Dust Group | Confirm IIIC requirement for combustible dust areas |
| Material | Choose stainless steel 316L for marine, chemical, outdoor, coastal, and corrosive locations |
| Cable Entries | Confirm M16 or project-required cable gland sizes |
| Terminals | Confirm terminal quantity, terminal capacity, current rating, and earth terminal requirement |
| IP Rating | Maintain IP66 after cable gland and stopping plug installation |
| Temperature Class | Confirm T6/T80°C or T4/T130°C based on ambient temperature and project requirement |
The ATEX Stainless Steel Terminal & Junction Box Ex e can support different hazardous area wiring requirements depending on the final assembly and installed components.
| Protection Type | Meaning | Common Use |
|---|---|---|
| Ex eb / Ex e | Increased safety protection | Terminal wiring, junction circuits, control wiring, lighting circuits |
| Ex i / IS | Intrinsic safety protection | Low-energy instrument loops, transmitters, sensors, alarms, signal circuits |
| Ex tb | Dust protection by enclosure | Zone 21 and Zone 22 combustible dust areas |
| Zone 1 / Zone 2 | Gas hazardous area classification | Oil & gas, refinery, petrochemical, process plants |
| Zone 21 / Zone 22 | Dust hazardous area classification | Dust-risk industrial and process areas |
| IP66 | Dust-tight and water-jet protection | Outdoor, marine, chemical, and process environments |
An IS Terminal Box is used for intrinsically safe circuits where electrical energy is limited to reduce ignition risk. The enclosure can support IS wiring only when the full assembly uses approved Ex i components and follows the correct wiring rules.
For Ex Proof Terminal Box in Sharjah projects involving IS circuits, check these points before final selection:
This helps the terminal box support safe wiring for instrument loops, sensors, transmitters, alarms, signal circuits, and low-energy control systems.
Many buyers use terms such as flame proof terminal box, explosion proof terminal box, Ex proof enclosure, and ATEX terminal box together. However, they can refer to different Ex protection concepts.
| Term | Meaning |
|---|---|
| Ex e / Increased Safety Terminal Box | Designed to reduce ignition risk through safer terminals, insulation, spacing, and temperature control |
| Flame Proof / Ex d Terminal Box | Designed to contain an internal explosion and stop flame transmission outside the enclosure |
| IS Terminal Box / Ex i | Used for low-energy circuits that cannot ignite the surrounding atmosphere under approved conditions |
| Ex tb Terminal Box | Designed to protect electrical equipment in combustible dust areas |
| ATEX Stainless Steel Terminal & Junction Box Ex e | Mainly an Ex e / Ex eb stainless steel terminal box with Ex tb dust protection |
This distinction matters in Sharjah projects because consultants, EPC contractors, and inspectors may require a specific protection concept. Always confirm whether the site needs Ex e increased safety, Ex d flameproof, Ex i intrinsic safety, or Ex tb dust protection before ordering.
Certifications help buyers choose the correct terminal box for hazardous area projects. The final enclosure must match the site zone, protection type, gas group, dust group, terminal design, cable gland system, IP rating, temperature class, and project specification.
The certificate data includes CML 20 ATEX 3156X, marking II 2 GD, Ex eb IIC T Gb, Ex tb IIIC T* Db**, temperature ratings T6/T80°C at +40°C and T4/T130°C at +60°C, plus IECEx CML 20.0094X and UKCA CML 21 UKEX 3892X approvals.
Correct installation helps the ATEX Stainless Steel Terminal & Junction Box Ex e maintain hazardous area safety. The installer must check the certificate, Ex marking, cable glands, terminal layout, wiring clearance, grounding, gasket, cover screws, sealing, and unused entries before energising the circuit.
Use trained personnel for hazardous area installation. Follow the project specification, certificate limits, manufacturer instructions, inspection requirements, and site area classification.
The ATEX Stainless Steel Terminal & Junction Box Ex e gives industries a compact, corrosion-resistant, and certified solution for hazardous area wiring. It supports safe terminal protection, field cable management, IS circuit planning, dust protection, and reliable performance in harsh industrial environments.
For Sharjah projects, this terminal box suits oil & gas, petrochemical, refinery, chemical, marine, power, automation, logistics, utilities, and infrastructure applications. Its AISI 316L stainless steel body, Ex eb IIC gas protection, Ex tb IIIC dust protection, IP66 rating, compact size, and ready-to-use terminal configuration make it useful for hazardous area installations.
1. What is an ATEX Stainless Steel Terminal & Junction Box Ex e used for?
It protects terminals, cable connections, instrument loops, lighting circuits, and control wiring in hazardous area installations.
2. Is this suitable for Ex Proof Terminal Box in Sharjah projects?
Yes, it suits Sharjah hazardous area projects when the Ex marking, certificate, terminal layout, cable entries, and site classification match the requirement.
3. What material is used?
The enclosure uses 1.5 mm AISI 316L / 1.4404 stainless steel.
4. What hazardous zones can it support?
It supports Zone 1, Zone 2, Zone 21, and Zone 22 when the site classification and final marking match.
5. What is the main protection type?
The main protection type is Ex eb increased safety, with Ex tb dust protection.
6. Can it be used as an IS Terminal Box?
Yes, it can support IS circuits only when approved Ex i components, barriers, wiring separation, and certification rules are followed.
7. What IP rating does it provide?
The enclosure provides IP66 ingress protection.
8. What terminals are included?
The listed terminal assembly includes 6 x 2.5 mm² terminals and 2 x 2.5 mm² PE terminals.
9. What cable glands are included?
The listed configuration includes 2 x M16 bottom cable entries, 1 x M16 left cable entry, and 1 x M16 right cable entry.
10. Who supplies ATEX Stainless Steel Terminal & Junction Boxes Ex e globally?
Atex Hub supplies ATEX Stainless Steel Terminal & Junction Boxes Ex e across UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide.
The ATEX Stainless Steel Terminal & Junction Box Ex e gives industries a compact and certified stainless steel solution for hazardous area terminal wiring and junction protection. It helps protect cable connections, terminals, instrument loops, lighting circuits, and control wiring while supporting safer installation in explosive gas and dust environments.
For buyers searching for Ex Proof Terminal Box in Sharjah, this product offers strong value for oil & gas, petrochemical, refinery, chemical, marine, power, automation, logistics, and industrial projects. Its AISI 316L stainless steel construction, Ex eb IIC protection, Ex tb IIIC dust protection, IP66 ingress rating, IK09 / IK10 shock resistance, and compact ready-to-use terminal layout make it suitable for demanding hazardous area applications.
Atex Hub supplies ATEX Stainless Steel Terminal & Junction Boxes Ex e globally across UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide, helping industries source safe and compliant hazardous area terminal box solutions for Ex installations.