If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The ATEX Air Conditioner Split Systems provide reliable cooling and heating for rooms located in hazardous gas and vapour environments. As a dependable Ex Proof Split AC in Dubai, the system combines an explosion-protected indoor unit, outdoor condensing unit, and suitable remote control for technical rooms, battery rooms, analyser shelters, offshore areas, and industrial facilities.
These split systems use integrated explosion-protection measures while retaining the familiar operation and installation advantages of a conventional air-conditioning system. Available capacities cover compact rooms as well as larger technical spaces, with cooling outputs ranging from approximately 2.0 kW to 7.1 kW in the standard wall-mounted series. Heating capacity is also available through an integrated heat-pump function.
The units support Zone 2 hazardous-area applications and configurations for gas groups IIA, IIB, and IIC. Optional Zone 22 versions and alternative indoor-unit arrangements can support project-specific requirements. Atex Hub supplies these ATEX split AC systems across Dubai, Abu Dhabi, Sharjah, the UAE, Saudi Arabia, Qatar, Kuwait, Bahrain, Oman, Europe, Africa, and worldwide.
An ATEX Air Conditioner Split System is an explosion-protected HVAC arrangement designed to cool or heat enclosed spaces where flammable gases or vapours may occasionally occur.
The system contains an indoor evaporator unit and an outdoor condensing unit. Refrigerant lines, electrical cables, and condensate drainage connect both sections. The indoor unit removes heat from the room, while the outdoor unit rejects that heat into the surrounding environment.
A conventional split AC may include electrical contacts, relays, motors, circuit boards, and switching components that could become ignition sources. An Explosion Proof Split AC Unit incorporates protective modifications, tested components, and controlled electrical arrangements to reduce this risk.
The split configuration also keeps the compressor and condenser outside the conditioned room. This arrangement reduces internal noise and saves valuable space in technical or occupied areas.
The Ex Proof Split AC combines hazardous-area protection with dependable cooling and user-friendly operation.
The indoor unit draws warm room air across an evaporator coil. Refrigerant inside the coil absorbs heat, and the fan returns cooler air to the room.
The heated refrigerant travels through insulated copper piping to the outdoor unit. The compressor raises the refrigerant pressure, and the condenser releases the absorbed heat outdoors.
During heating mode, the refrigeration cycle reverses. The indoor unit releases heat into the room, while the outdoor coil absorbs heat from the external air.
Explosion-protection measures are applied to relevant electrical and mechanical components. The final system must be installed according to its certified configuration, hazardous-area classification, electrical design, and manufacturer-approved installation procedure.
The Hazardous Area Split AC Unit provides cooling and heating for enclosed industrial spaces where standard air conditioners may not be suitable.
| Specification | Product Details |
|---|---|
| Product Type | ATEX split air-conditioning system |
| Indoor Unit Type | Wall-mounted; alternative types available |
| Cooling Capacity | Approximately 2.0–7.1 kW in standard wall series |
| Heating Capacity | Approximately 2.7–8.2 kW |
| Cooling Range | Approximately 6,800–24,000 BTU/h |
| Electrical Supply | Approximately 220–240 V |
| Frequency | 50 Hz; 60 Hz option available |
| Refrigerant | R-410A or selected R32 configuration |
| Operating Function | Cooling and heat-pump heating |
| Hazardous Area | Zone 2; Zone 22 option for selected projects |
| Equipment Category | II 3G |
| Gas Groups | IIA, IIB and IIC according to configuration |
| Temperature Class | T3 according to selected certified version |
| Protection Marking | Configuration-dependent Ex marking |
| Outdoor Coil Protection | Blue-fin anti-corrosion treatment |
| System Components | Indoor unit, outdoor unit and compatible controller |
The standard product range includes models from approximately 2.0 kW to 7.1 kW cooling capacity, with heating outputs up to approximately 8.2 kW. Higher-capacity wall, ceiling, multi-split, and VRV arrangements are also available for selected projects.
The required unit should be selected according to room heat load, ambient conditions, occupancy, and installed equipment.
An ATEX split system provides several operational advantages in hazardous-area buildings.
Correct capacity selection and certified installation are essential for safe and dependable operation.
The selected split AC unit and complete installation should follow the applicable hazardous-area, electrical, and HVAC requirements.
Atex Hub supplies ATEX split air conditioners for hazardous-area cooling and technical climate-control projects.
1. What is an ATEX Split AC Unit?
An ATEX Split AC Unit is an explosion-protected air conditioner designed for cooling or heating rooms in classified hazardous areas.
2. Is the Ex Proof Split AC suitable for Dubai?
Yes, the Ex Proof Split AC in Dubai supports properly designed battery rooms, analyser shelters, control rooms, laboratories, and industrial buildings.
3. Which hazardous zone does the system support?
Standard configurations support Zone 2 gas and vapour environments, with selected Zone 22 options available.
4. Can the unit provide heating?
Yes, the integrated heat-pump function provides both cooling and heating.
5. Which cooling capacities are available?
Standard wall-mounted systems provide approximately 2.0 kW to 7.1 kW, while larger configurations are also available.
6. Can the system support gas group IIC?
Yes, suitable configurations support IIA, IIB, and IIC gas groups.
7. Which refrigerant does the unit use?
Depending on the selected configuration, the system can use R-410A or R32 refrigerant.
8. Can it be used in battery rooms?
Yes, it is suitable for properly assessed battery rooms where hydrogen gas may occasionally occur.
9. Are duty and standby controls available?
Yes, selected projects can use a duty/standby redundancy arrangement for critical cooling applications.
10. Does Atex Hub supply ATEX split AC systems worldwide?
Atex Hub supplies ATEX split air-conditioning systems worldwide, including the GCC, Europe, Africa, and other industrial markets.
The ATEX Air Conditioner Split Systems provide dependable temperature control for hazardous industrial rooms and technical buildings. Their explosion-protected construction, heat-pump operation, low-noise indoor units, and broad capacity range make them suitable for battery rooms, analyser shelters, refineries, offshore platforms, laboratories, control rooms, and chemical facilities.
Available cooling capacities range from compact 2.0 kW units to 7.1 kW wall-mounted systems, with larger arrangements available for demanding projects. Zone 2 configurations, gas-group options, corrosion protection, and remote operation support challenging industrial environments.
For organisations seeking a reliable Ex Proof Split AC in Dubai, these systems provide practical cooling and heating without relying on a large central HVAC arrangement. Atex Hub supplies these units across Dubai, the UAE, GCC countries, Europe, Africa, and worldwide.