If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The Atex Compact Triple IR (Mini IR3) Flame Detector is a small, powerful Ex Proof flame detector built for fast, reliable flame recognition in hazardous areas. Using advanced triple-infrared (IR3) sensing, it distinguishes real hydrocarbon fires from false alarms caused by sunlight, welding, or hot machinery. Its compact housing fits where space is tight—ideal for skids, shelters, and enclosed rooms common across the UAE, from offshore modules in Abu Dhabi to tank farms in Dubai and process halls in Sharjah. With ATEX/IECEx approvals and rugged environmental sealing, this detector helps you protect people, equipment, and uptime with confidence.
An Ex Proof flame detector is a fire safety device certified for explosive atmospheres (gas and dust). It “sees” flames by analysing light energy patterns emitted by combustion. The Mini IR3 looks at three infrared wavelengths and applies algorithms to verify a true fire quickly—often within seconds—while ignoring common industrial noise. Its flameproof (Ex d) or increased safety (Ex e) construction (model dependent) ensures that any internal fault won’t ignite the hazardous environment. In UAE conditions—heat, humidity, saline air, and airborne dust—the Mini IR3’s sealed optics, heated window option, and robust electronics deliver dependable performance day and night.
Across Dubai, Abu Dhabi, and Sharjah, operators use IR3 detectors where fast fire confirmation matters: hydrocarbon storage, loading bays, gas turbine enclosures, chemical pumps, paint lines, and analyser houses. The Mini IR3 shines in compact spaces where false alarm immunity is critical—beneath canopies, near reflective surfaces, or around process heaters. Its quick detection speeds up ESD logic, deluge release, or foam systems, cutting response time while keeping nuisance trips low. Compatible outputs (4–20 mA, relay, Modbus—model dependent) make integration with existing F&G or BMS/PLC straightforward.
Oil & Gas / Petrochem: Wellhead and separator skids, compressor enclosures, tank farms, truck and jetty loading.
Power & Utilities: Gas turbine/HRSG areas, fuel treatment and day tanks.
Chemicals & Industrial: Solvent storage, mixing rooms, paint spray booths, packaging with flammable vapours.
Marine & Ports (UAE): Jetty manifolds, bunkering stations, and cargo transfer points exposed to saline air.
Warehousing: Drum stores and hazardous goods bays needing long-range flame confirmation.
Buildings & OEM Skids: Analyzer shelters, HVAC plant rooms with flammable risks, compact OEM enclosures.
Choosing the Atex Compact Triple IR (Mini IR3) Flame Detector means getting fast detection, false-alarm resistance, and hazardous-area certification in a body small enough for crowded panels and skids. You’ll reduce time spent tuning out false alarms, improve emergency response, and simplify maintenance with accessible terminals and health indicators. Built for the Gulf, the detector pairs IP66/67 environmental protection with corrosion-resistant materials and wide operating temperatures—exactly what Dubai, Abu Dhabi, and Sharjah sites demand. Backed by Atex Hub, you receive the certificates and drawings your HSE team needs for swift approvals.
| Parameter | Specification |
|---|---|
| Product Name | Atex Compact Triple IR (Mini IR3) Flame Detector |
| Detection Principle | Triple-Infrared (IR3) flame analysis with false-alarm rejection algorithms |
| Certification | ATEX & IECEx (gas/dust variants, model dependent) |
| Zone/Class | Gas: Zone 1 / Zone 2; Dust: Zone 21 / Zone 22 |
| Protection | Ex d (flameproof) and/or Ex e (increased safety), per model |
| Ingress Protection | IP66 / IP67 (IEC 60529) |
| Response Time | Fast — milliseconds to seconds (fuel & distance dependent) |
| Field of View | Wide FOV; long-range hydrocarbon flame detection (model dependent) |
| Outputs | 4–20 mA, Alarm/ Fault relays; optional Modbus/RS-485 (model dependent) |
| Power Supply | 18–32 VDC (typical); low current draw |
| Operating Temp. | −40 °C to +75 °C (typical model range) |
| Window Options | Heated window (anti-condensation/ice), optical self-test |
| Housing Material | Coated aluminium or stainless steel (marine grade options) |
| Mounting | Adjustable bracket; alignment sight marks |
| Accessories | Sun shield, weather hood, test lamp, junction box kits |
| Documents | Datasheet, wiring diagram, GA drawing, test/inspection report, ATEX/IECEx certificates |
ATEX Directive 2014/34/EU – equipment for explosive atmospheres
IECEx Scheme – international certification for Ex equipment
EN 60079-0 – Explosive atmospheres: General requirements
EN 60079-1 – Flameproof enclosure “d” protection
EN 54-10 – Fire detection and alarm systems – Flame detectors (point type)
IEC 60529 – IP ratings (IP66/IP67)
1) How does IR3 reduce false alarms in Dubai plants?
By comparing three IR bands and flame flicker patterns, the detector ignores hot pipes, sunlight, and welding, confirming only real flame signatures.
2) Is the Mini IR3 suitable for Abu Dhabi offshore sites?
Yes. With ATEX/IECEx approvals, IP66/67 sealing, marine-grade materials, and optional heated window, it suits offshore modules and jetties.
3) Can it see through glass or dirty air?
Clearview windows are best. Light smoke or mist is tolerated; heavy obscuration reduces range. A heated window helps prevent condensation and salt film.
4) What outputs are available for Sharjah warehouses?
Standard 4–20 mA and dry alarm/fault relays; many models offer RS-485/Modbus for easy F&G panel integration.
5) How far can it detect a fire?
Range depends on fuel type, size, and line-of-sight. Hydrocarbon pool fires are detected at significant distances; see the project datasheet for exact figures.
6) How often should I test the detector?
Follow your site F&G maintenance plan. Use the approved IR test lamp for routine function checks and verify relays/ loops at the panel.
7) Who supplies documentation in the UAE?
Atex Hub provides the certificate pack, GA/wiring drawings, inspection reports, and nameplate data for quick approvals across the UAE.
The Atex Compact Triple IR (Mini IR3) Flame Detector delivers fast, accurate, and Ex Proof flame detection in compact form—built for real-world conditions in Dubai, Abu Dhabi, and Sharjah. With IR3 sensing, ATEX/IECEx approvals, and rugged IP66/67 protection, it helps you cut false alarms, accelerate response, and protect critical assets. Supplied and supported by Atex Hub, it’s a smart, compliant choice for Ex Proof Flame Detector in UAE projects that demand reliability with minimal fuss.