

If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The EXKO 7318 Ex-Main Circuit Breaker provides safe main power switching, circuit isolation, and motor circuit control in hazardous industrial areas. It helps operators make, break, isolate, and protect electrical circuits under normal operating conditions and during exceptional conditions such as short-circuit situations.
For companies searching for Ex Proof Circuit Breaker in Oman, this product suits ATEX circuit breaker, explosion proof circuit breaker, flame proof circuit breaker, hazardous area circuit breaker, intrinsically safe circuit breaker, and Ex proof circuit breaker requirements. It works well in oil & gas plants, refineries, petrochemical sites, chemical plants, power stations, ports, utilities, workshops, factories, control panels, motor systems, and industrial automation projects.
Atex Hub supplies Ex proof circuit breakers globally across Oman, UAE, Saudi Arabia, Qatar, Kuwait, Bahrain, Europe, Africa, and worldwide, helping industries source certified hazardous-area electrical protection and isolation solutions.
The EXKO 7318 Ex-Main Circuit Breaker is an ATEX main current circuit breaker range used for switching and isolating power circuits in hazardous areas. It allows operators to make or break circuits during normal operation and also supports cutting in, briefly conducting, and cutting out currents during exceptional conditions such as short circuits. The product range is available with rated current options from 63A to 630A.
This type of hazardous area circuit breaker suits motor circuits, power circuits, distribution systems, and main isolation points where a certified Ex-rated electrical solution is required. The product range also offers full AC-3 motor switching capacity, isolating properties, clear switch position indication, and an installation-friendly design.
The EXKO 7318 Ex-Main Circuit Breaker gives industrial teams a safe and reliable switching solution for hazardous-area power circuits. It supports heavy industrial use where explosive atmospheres, motor loads, short-circuit conditions, outdoor exposure, and demanding maintenance routines may exist.
The source product page lists available models for 63A, 125A, 160A, 250A, 400A, and 630A, with features such as full AC-3 motor switching capacity, high IP protection, and simple system integration.
The EXKO 7318 Ex-main circuit breaker helps isolate and control power circuits safely in classified industrial locations. It suits projects where standard circuit breakers cannot meet hazardous-area safety, switching, isolation, and motor control requirements.
| Specification | Details |
|---|---|
| Product Name | EXKO 7318 Ex-Main Circuit Breakers |
| Product Type | ATEX Ex-Main Circuit Breaker / Main Current Switch |
| Rated Current Range | 63A – 630A |
| Available Models | 63A, 125A, 160A, 250A, 400A, 630A |
| Switching Function | Making and breaking circuits under normal operating conditions |
| Exceptional Condition Function | Cutting in, briefly conducting, and cutting out currents under exceptional conditions such as short circuiting |
| Motor Switching Capacity | Full AC-3 motor switching capacity |
| Isolating Properties | According to EN 60947-4-1 |
| Main Contact Opening | Compulsory opening of main current contacts according to EN 60204-1 |
| Protection | High degree of IP protection |
| Switch Position | Clearly indicated and easily visible |
| Connection Terminals | Easily accessible terminals |
| System Integration | Installation-friendly design |
| Optional Integration Parts | Metal screw-on flanges, plastic flanges, or brass flanges depending on version |
| Explosion Group Option | Available for Explosion Group IIB applications |
| Supplier | Atex Hub |
The product information highlights rated current from 63A to 630A, full AC-3 motor switching capacity, isolating properties to EN 60947-4-1, compulsory opening of main current contacts to EN 60204-1, visible switch position, and accessible connection terminals.
The correct Ex proof circuit breaker depends on the hazardous zone, rated current, motor load, switching duty, explosion group, enclosure style, cable entry method, maintenance requirement, and project approval standard.
| Selection Point | What to Check |
|---|---|
| Rated Current | Select from 63A, 125A, 160A, 250A, 400A, or 630A based on load requirement |
| Load Type | Confirm whether the circuit includes motors, distribution loads, or main power circuits |
| Motor Duty | Check AC-3 motor switching requirement |
| Isolation Need | Confirm isolating properties and visible switch position |
| Explosion Group | Check whether Explosion Group IIB is suitable for the project |
| Installation Style | Select enclosure, flange, and cable entry arrangement as per site design |
| Terminals | Confirm access for connection and future maintenance |
| Short-Circuit Coordination | Match upstream protection and system fault current requirements |
| IP Protection | Confirm the required ingress protection based on indoor, outdoor, dusty, or wet areas |
| Compliance | Confirm ATEX documentation, datasheet, project specification, and inspection approval |
A standard industrial circuit breaker may protect normal electrical installations, but it does not automatically suit hazardous areas. A hazardous-area main circuit breaker must support certified Ex use, safe isolation, motor switching, clear position indication, and approved installation inside classified zones.
The EXKO 7318 Ex-Main Circuit Breaker helps bridge this gap by combining main current switching, isolation, motor switching capacity, and hazardous-area suitability. For industrial projects in Oman, this matters because oil & gas sites, ports, petrochemical units, and utility plants need switching equipment that can handle real industrial loads and still meet Ex-area safety requirements.
Many buyers use ATEX circuit breaker, explosion proof circuit breaker, flame proof circuit breaker, hazardous area circuit breaker, intrinsically safe circuit breaker, and Ex proof circuit breaker together. However, each term can describe a different hazardous-area protection method or application.
| Term | Meaning |
|---|---|
| ATEX Circuit Breaker | Circuit breaker solution certified or selected for explosive atmosphere locations |
| Explosion Proof Circuit Breaker | Circuit breaker assembly used in explosion-risk areas with Ex-rated protection |
| Flame Proof Circuit Breaker | Circuit breaker solution used where flameproof / Ex-rated protection is required |
| Hazardous Area Circuit Breaker | Circuit breaker used in classified industrial areas |
| Intrinsically Safe Circuit Breaker | Low-energy circuit protection selected for Ex i circuits where approved |
| Ex Proof Circuit Breaker | General term for circuit breakers used in hazardous-area certified systems |
| Ex-Main Circuit Breaker | Main current breaker used for isolation and switching in hazardous-area power circuits |
This difference matters in Oman projects because consultants, EPC contractors, safety teams, and inspectors may ask for a specific protection method. Always confirm whether the final project needs Ex d, Ex e, Ex i, Ex tb, or another approved hazardous-area arrangement.
Correct installation keeps the EXKO 7318 Ex-Main Circuit Breaker safe and reliable. The installer must check the rating, Ex documentation, load type, cable size, upstream protection, enclosure integration, switch position indication, and maintenance clearance before commissioning.
Standards help buyers choose the correct hazardous-area circuit breaker for main current switching and motor circuit isolation. The final product must match the project’s hazardous-area classification, rated current, motor duty, switching category, isolation requirement, cable system, and inspection criteria.
The product page states that EXKO 7318 circuit breakers provide full AC-3 motor switching capacities and isolating properties according to EN 60947-4-1, with compulsory opening of main current contacts according to EN 60204-1. It also states that the circuit breakers are available for Explosion Group IIB applications.
The EXKO 7318 Ex-Main Circuit Breaker gives industries a strong certified solution for main power isolation, motor switching, and hazardous-area electrical control. It supports larger rated currents, visible switching position, accessible connection terminals, and integration into industrial electrical systems.
For Oman projects, this circuit breaker suits oil & gas, petrochemical, refinery, chemical, marine, port, utility, power, automation, factory, workshop, control panel, and infrastructure applications. Its 63A–630A current range, AC-3 motor switching capacity, isolating properties, clear switch position indication, and installation-friendly construction make it useful for demanding hazardous-area power switching applications.
1. What is EXKO 7318 Ex-Main Circuit Breaker used for?
It is used for main current switching, circuit isolation, and motor circuit control in hazardous industrial areas.
2. Is this suitable for Ex Proof Circuit Breaker in Oman projects?
Yes, it suits Oman hazardous-area projects when the current rating, motor duty, Ex requirement, and site classification match the project specification.
3. What rated current options are available?
The range includes 63A, 125A, 160A, 250A, 400A, and 630A models.
4. Can it handle motor switching?
Yes, the product page highlights full AC-3 motor switching capacity.
5. Does it provide isolating properties?
Yes, the product information states isolating properties according to EN 60947-4-1.
6. Is the switch position visible?
Yes, the switch position is clearly indicated and easily seen.
7. Are the connection terminals accessible?
Yes, the design includes easily accessible connection terminals.
8. Can it support Explosion Group IIB applications?
Yes, the product information states that the circuit breakers are also available for Explosion Group IIB applications.
9. Where can it be used in Oman?
It suits Muscat, Sohar, Duqm, Salalah, Nizwa, Sur, oilfields, ports, utilities, factories, workshops, and infrastructure projects.
10. Who supplies Ex proof circuit breakers globally?
Atex Hub supplies Ex proof circuit breakers across Oman, UAE, Saudi Arabia, Qatar, Kuwait, Bahrain, Europe, Africa, and worldwide.
The EXKO 7318 Ex-Main Circuit Breaker gives industries a safe and reliable solution for hazardous-area main current switching, motor circuit control, and electrical isolation. It supports rated currents from 63A to 630A, full AC-3 motor switching capacity, visible switch position indication, and installation-friendly connection access.
For buyers searching for Ex Proof Circuit Breaker in Oman, this product offers strong value for oil & gas, petrochemical, refinery, chemical, marine, port, utility, power, automation, factory, workshop, control panel, and infrastructure projects. Its high current range, motor switching capability, isolating properties, and Ex-area suitability make it a practical choice for demanding hazardous-area electrical systems.
Atex Hub supplies EXKO 7318 Ex-main circuit breakers globally across Oman, UAE, Saudi Arabia, Qatar, Kuwait, Bahrain, Europe, Africa, and worldwide, helping industries source safe and compliant hazardous-area circuit breaker solutions.