In hazardous sites, a weak cable entry can cause leaks, faults, or even ignition. The Atex Cable Gland SS Series solves this by giving you a strong, sealed, and certified entry point for your cables. Made from stainless steel 316/316L, it resists heat, sand, humidity, and salt air—perfect for Sharjah, and equally reliable in Dubai and Abu Dhabi. It keeps dust and water out, maintains earth continuity, and preserves your enclosure’s Ex protection. Use it on junction boxes, motors, lights, beacons, and control panels. With local supply via Atex Hub, you get the right thread and size fast, so jobs finish on time and pass audits with ease.
what is Ex Proof Cable Gland in Sharjah
An Ex Proof Cable Gland is a certified device that holds and seals a cable where it enters Ex equipment. It keeps the flameproof (Ex d), increased safety (Ex e), or dust (Ex tb) protection intact. In simple words: it’s the safe doorway for your cable. The SS Series gives secure clamping, IP-rated sealing, and grounding where needed. It works with both armoured (SWA/AWA) and unarmoured cables. In Sharjah, teams use it on refineries, terminals, marine decks, and industrial plants to meet Zone 1/2 (gas) and Zone 21/22 (dust) rules without slowing work.
key uses of Ex Proof Cable Gland in Sharjah
Terminate armoured and unarmoured cables cleanly into Ex-rated enclosures.
Keep IP66/68 sealing under sandstorms, washdowns, and coastal spray.
Bond Armor and maintain earth continuity for safe fault clearing.
Match Metric, NPT, and BSP threads on brownfield and new builds.
Cut rework with wide clamping ranges, clear markings, and simple torque steps.
From Hamriyah Free Zone (Sharjah) to Jebel Ali (Dubai) and Mussafah/Ruwais (Abu Dhabi), it delivers consistent, audit-ready results.
key applications
Oil & Gas / LNG: analyser houses, compressor shelters, tank farms, loading skids.
Petrochemical / Chemical: MCCs, field JBs, dosing skids, pump panels.
Marine & Offshore: deck lighting, winches, alarms/beacons, helideck systems.
Power & Utilities: turbine enclosures, fuel-gas trains, substations.
Dust Zones (Food, Pharma, Cement): mills, conveyors, and bagging lines (Zone 21/22).
Why choose Ex Proof Cable Gland in Sharjah
Three reasons: compliance, durability, speed.
Compliance: ATEX/IECEx approvals, correct Ex concepts (Ex d/Ex e/Ex tb), clear markings, and traceability.
Durability: full 316/316L stainless steel resists corrosion, UV, and Gulf weather.
Speed: broad clamping ranges and common threads reduce install time and help you meet shutdown windows.
With Atex Hub in the UAE, you get quick delivery and the exact size, seal, and thread your cable list demands.
Technical Specifications of Atex Cable Gland – SS Series
| Parameter | Specification |
|---|---|
| Series | Atex Cable Gland – SS Series (Stainless Steel) |
| Certification (typical) | ATEX & IECEx, Equipment Group II for Gas & Dust |
| Ex Protection Concepts | Ex d (flameproof), Ex e (increased safety), Ex tb (dust) — model dependent |
| Zones & Groups | Zone 1 & 2 (Gas); Zone 21 & 22 (Dust); Gas IIA/IIB/IIC; Dust IIIC |
| Ingress Protection | IP66 / IP68 when installed with specified seals and torque |
| Cable Types | Armoured (SWA/AWA) and Unarmoured, circular single/multicore |
| Armor Termination | Positive mechanical clamping; verified earth continuity |
| Cable OD Range | Wide clamping spans (e.g., 6–90 mm, size-dependent) |
| Thread Options | Metric (M16–M63), NPT (⅜”–2″), BSPP/BSPT (G/R) |
| Body Material | Stainless Steel 316/316L (marine-grade corrosion resistance) |
| Seal Materials | NBR, FKM (Viton®), EPDM, PTFE (match media/temperature) |
| Temperature Range | -40°C to +105/120°C (verify per seal and T-class) |
| T-Class (typical) | Up to T4/T6 depending on model and conditions |
| Accessories | Shrouds, earth tags, locknuts, entry thread seals, reducers/adaptors |
| Marking & Traceability | Laser-etched Ex code, size, and batch number |
Certifications, Compliance & Standards
FAQs
1) What makes the SS Series “Ex proof”?
It preserves Ex protection (Ex d/Ex e/Ex tb) and is certified so the entry won’t become an ignition source when installed correctly.
2) Can it handle both armoured and unarmoured cables?
Yes—choose the right SS Series variant for SWA/AWA or unarmoured cables.
3) Which thread should I pick for Sharjah projects?
Most new builds use Metric. For brownfield gear, you may need NPT or BSP. The SS Series supports all.
4) How do we keep IP66/68 after installation?
Use the supplied seals, add thread washers where needed, and torque to the specified values.
5) Why stainless steel 316/316L?
It delivers strong corrosion resistance against salt spray, humidity, and heat in Sharjah, Dubai, and Abu Dhabi.
6) What seal material should I choose?
Match your media and temperature. NBR/FKM/EPDM/PTFE cover most oil, chemical, and heat needs.
7) Where can I buy in the UAE?
From Atex Hub, with local stock and help mapping sizes to your cable OD list and thread plan.
Conclusion
The Atex Cable Gland SS Series gives you safe, sealed, and corrosion-resistant cable entries for Sharjah, Dubai, and Abu Dhabi. It keeps Ex integrity, blocks dust and water, and maintains earth continuity—so your installs are neat, reliable, and audit-ready. With wide sizes, common threads, and trusted certifications, it helps your team finish right the first time. For quick supply and guidance in the UAE, choose Atex Hub.