If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The ATEX Split Cable Entry Frames – KEL-ER Series provide a safe and practical cable entry solution for routing and sealing pre-terminated cables in industrial enclosures, control panels, junction boxes, and machine housings. These split cable entry frames help installers pass connectorised cables through enclosure walls without cutting, stripping, or removing the connector.
For companies searching for Ex Proof Cable Entry Frame in Dubai, this product suits ATEX cable entry systems, explosion proof cable entry systems, flame proof cable entry systems, hazardous area cable entry systems, and intrinsically safe cable entry systems search requirements. It supports cable routing, cable sealing, strain relief, enclosure entry, panel cable management, industrial wiring, machine cable entry, and hazardous-area enclosure projects.
Atex Hub supplies Ex proof cable entry frames and hazardous-area cable entry solutions globally across Dubai, UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide, helping industries source suitable cable entry products for panels, cabinets, enclosures, machines, and industrial systems.
The ATEX Split Cable Entry Frames – KEL-ER Series are split cable entry frames designed for routing and sealing pre-terminated cables. They support cable diameters from 2 mm to 16 mm with KT 2–15 grommets and from 16 mm to 34 mm with KT 16–34 grommets. The split frame design allows installers to route cables that already have connectors attached.
The KEL-ER ATEX range uses injected sealing and provides IP65 protection. The product data also lists IP65 / IP66, UL Type 4X / 12, polyamide material, graphite fire penetration seal, black RAL 9005 colour, and strain relief support.
These cable entry frames suit potentially explosive atmospheres in equipment group II, category 2 + 3, and zones 1, 2, 21, and 22 for gas and dust applications. The KEL-ER 24 ATEX frame matches the cut-out dimensions for 24-pole standard industrial connectors.
The KEL-ER Series ATEX split cable entry frame gives panel builders and maintenance teams a strong cable entry system for routing, sealing, and protecting pre-terminated cables. It supports hazardous-area enclosure work, cable strain relief, high sealing performance, and fast assembly.
Cable grommets are placed into compartments and fixed securely to the frame during assembly, helping installers achieve stable cable routing and sealing.
The ATEX Split Cable Entry Frames – KEL-ER Series help industries route pre-terminated cables safely into enclosures and panels. They suit applications where installers need sealed cable entry, connector protection, strain relief, and hazardous-area suitability.
| Specification | Details |
|---|---|
| Product Name | ATEX Split Cable Entry Frames – KEL-ER Series |
| Product Type | ATEX / Ex Proof / Hazardous Area Split Cable Entry Frame |
| Main Use | Routing and sealing pre-terminated cables |
| Cable Range | 2 mm to 16 mm with KT 2–15 grommets |
| Large Cable Range | 16 mm to 34 mm with KT 16–34 grommets |
| Hazardous Area Suitability | Equipment Group II, Category 2 + 3 |
| Zone Suitability | Zone 1, Zone 2, Zone 21, Zone 22 |
| Hazard Type | Gas and dust hazardous areas |
| Protection Class | IP65 |
| Listed IP Ratings | IP65, IP66 |
| UL Type | 4X, 12 |
| Material | Polyamide |
| Fire Penetration Seal Material | Graphite |
| Colour | Black, RAL 9005 |
| Fire Barrier Standards | E45, EI30 |
| Properties | Intumescent, halogen free, silicone free |
| Strain Relief | Included |
| Test Standards | EN 45545-2, EN 45545-3, EN 1363-1 |
| Connector Cut-Out Match | KEL-ER 24 ATEX matches 24-pole standard industrial connector cut-outs |
| Supplier | Atex Hub |
The product data lists IP65 / IP66, UL Type 4X / 12, polyamide, graphite fire penetration seal, E45 / EI30, intumescent, halogen-free, silicone-free, strain relief, and test standards EN 45545-2, EN 45545-3, and EN 1363-1.
The correct Ex Proof Cable Entry Frame in Dubai depends on cable size, cable count, enclosure cut-out, hazardous-area zone, IP rating, fire barrier requirement, grommet selection, and installation method.
| Selection Point | What to Check |
|---|---|
| Cable Type | Confirm cables are pre-terminated or connectorised |
| Cable Diameter | Select grommets for 2–16 mm or 16–34 mm cable ranges |
| Hazardous Zone | Confirm Zone 1, Zone 2, Zone 21, or Zone 22 requirement |
| Gas / Dust Area | Confirm whether the application involves gas, dust, or both |
| Equipment Category | Confirm Group II, Category 2 + 3 requirement |
| IP Requirement | Confirm IP65 / IP66 requirement |
| UL Type Need | Confirm whether UL Type 4X / 12 suits the enclosure project |
| Fire Barrier Need | Confirm E45 / EI30 and test standard requirements |
| Material Requirement | Confirm polyamide and graphite seal suitability |
| Connector Cut-Out | Check whether 24-pole standard industrial connector cut-out is required |
| Strain Relief | Confirm strain relief requirement for cable movement and vibration |
| Compliance | Confirm datasheet, certificate, enclosure approval, cable routing method, and site classification before procurement |
A split cable entry frame helps installers route pre-terminated cables without removing connectors. This saves installation time and avoids cutting factory-assembled cables. It also reduces rewiring errors, connector damage, and downtime during retrofit or maintenance work.
In Dubai industrial panels and machine enclosures, this design helps teams manage automation cables, fieldbus cables, sensor cables, actuator cables, power cables, and control cables more efficiently.
Hazardous-area equipment must match the site classification. Zone 1 and Zone 2 apply to gas and vapour atmospheres, while Zone 21 and Zone 22 apply to combustible dust atmospheres.
The KEL-ER ATEX range supports equipment group II, category 2 + 3, and zones 1, 2, 21, and 22 for gas and dust applications. This makes it useful for approved enclosure projects in refineries, petrochemical plants, process plants, storage facilities, ports, utilities, and industrial automation sites.
Cable entry points often face dust, humidity, water spray, washdown, and outdoor exposure. IP65 helps protect against dust and water jets, while IP66 supports stronger water-jet protection where the full installed assembly maintains the rating.
For Dubai projects, this matters in Jebel Ali, DIP, Dubai Industrial City, ports, process plants, factories, utilities, warehouses, and outdoor control panel locations. Installers must use correct grommets, frame assembly, gasket compression, and enclosure preparation to maintain the required protection level.
The KEL-ER ATEX data lists E45 and EI30 fire barrier standards, with test standards EN 45545-2, EN 45545-3, and EN 1363-1. This supports cable entry projects where fire resistance and smoke performance matter in selected industrial or transportation applications.
Fire barrier requirements should always be checked against the full wall, enclosure, panel, or cabinet assembly. The cable entry frame alone should not be treated as the complete fire-rated system unless the full installation matches approved test conditions.
The KEL-ER ATEX frame uses a graphite fire penetration seal and lists intumescent properties. Intumescent material expands when exposed to heat, helping close gaps and support fire barrier performance in approved assemblies.
This can help projects where cable entries must support both cable sealing and fire protection requirements. However, installers must always follow the correct assembly instructions, grommet selection, cable diameter matching, and fire test conditions.
Many buyers use ATEX cable entry systems, explosion proof cable entry systems, flame proof cable entry systems, hazardous area cable entry systems, and intrinsically safe cable entry systems together. However, each term can describe a different enclosure entry requirement or protection method.
| Term | Meaning |
|---|---|
| ATEX Cable Entry Systems | Cable entry systems selected for Ex-rated enclosure projects where approval allows |
| Explosion Proof Cable Entry Systems | Cable entry products used in hazardous-area enclosure applications |
| Flame Proof Cable Entry Systems | Cable entry systems selected for flameproof or Ex-rated projects |
| Hazardous Area Cable Entry Systems | Cable entry systems used in classified gas, vapour, dust, or industrial areas |
| Intrinsically Safe Cable Entry Systems | Cable entry systems used with approved low-energy Ex i wiring and compliant enclosures |
| Split Cable Entry Frame | Frame used to route connectorised cables without removing connectors |
| Fire Barrier Cable Entry Frame | Cable entry frame designed to support fire barrier performance in approved assemblies |
| Cable Grommet System | Grommet-based cable entry method that seals cables inside a frame |
This difference matters in Dubai projects because consultants, EPC contractors, safety teams, and inspectors may ask for a specific protection method. Always confirm whether the project needs ATEX certification, Zone 1, Zone 2, Zone 21, Zone 22, IP65, IP66, UL Type 4X, E45, EI30, EN 45545, EN 1363-1, or intrinsically safe wiring selection.
Correct installation helps the ATEX Split Cable Entry Frames – KEL-ER Series perform safely and reliably. The installer must check cable diameter, grommet selection, cut-out size, hazardous-area classification, gasket compression, cable strain relief, fire barrier requirement, and enclosure approval before installation.
Certifications and standards help buyers select the correct cable entry frame for hazardous-area, industrial, and fire barrier projects. The final selection must match the enclosure design, hazardous zone, gas or dust classification, IP requirement, cable diameter, fire requirement, and site inspection standard.
The KEL-ER ATEX product data lists use in potentially explosive atmospheres for gas and dust, equipment group II, category 2 + 3, zones 1, 2, 21, and 22, and certification to the ATEX directive. It also lists IP65 / IP66, UL Type 4X / 12, E45 / EI30, and test standards EN 45545-2, EN 45545-3, and EN 1363-1.
The ATEX Split Cable Entry Frames – KEL-ER Series give industries a practical and Ex-rated cable entry solution for routing and sealing pre-terminated cables. They support 2 mm to 16 mm cables with KT 2–15 grommets, 16 mm to 34 mm cables with KT 16–34 grommets, Zone 1, Zone 2, Zone 21, Zone 22, IP65 / IP66, UL Type 4X / 12, polyamide construction, graphite fire penetration seal, E45 / EI30, intumescent properties, halogen-free material, silicone-free material, and strain relief.
For Dubai projects, this cable entry frame suits oil & gas, petrochemical, refinery, automation, control panels, machine building, industrial enclosures, utilities, factories, warehouses, workshops, process plants, ports, skids, maintenance panels, and infrastructure applications. Its split frame design, ATEX suitability, grommet-based sealing, fire barrier performance, and secure cable routing make it useful for demanding hazardous-area cable entry projects.
1. What are ATEX Split Cable Entry Frames – KEL-ER Series used for?
They route and seal pre-terminated cables through panels, enclosures, cabinets, and machine housings.
2. Are these suitable for Ex Proof Cable Entry Frame in Dubai projects?
Yes, they can suit Dubai hazardous-area projects when the enclosure approval, cable diameter, zone classification, IP rating, and site inspection requirement match the installation.
3. What cable diameters does the KEL-ER ATEX frame support?
It supports 2 mm to 16 mm cables with KT 2–15 grommets and 16 mm to 34 mm cables with KT 16–34 grommets.
4. Which hazardous zones does it support?
It supports Zones 1, 2, 21, and 22 for gas and dust applications in equipment group II, category 2 + 3.
5. What IP rating does it provide?
The product data lists IP65 protection and also specifies IP65 / IP66 ratings.
6. What UL Type rating is listed?
The product data lists UL Type 4X and 12.
7. What material does the frame use?
It uses polyamide with a graphite fire penetration seal.
8. Does it support fire barrier requirements?
Yes, the product data lists E45 and EI30 fire barrier standards with test standards EN 45545-2, EN 45545-3, and EN 1363-1.
9. Where can it be used in Dubai?
It suits Dubai, Jebel Ali, Dubai Industrial City, Dubai South, DIP, ports, warehouses, utilities, factories, workshops, process plants, refineries, machine builders, automation panels, and infrastructure sites.
10. Who supplies Ex proof cable entry frames globally?
Atex Hub supplies Ex proof cable entry frames and hazardous-area cable entry solutions across Dubai, UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide.
The ATEX Split Cable Entry Frames – KEL-ER Series give industries a strong and practical solution for routing and sealing pre-terminated cables in hazardous-area enclosure projects. They support 2 mm to 16 mm and 16 mm to 34 mm cable ranges, Zone 1, Zone 2, Zone 21, Zone 22, IP65 / IP66, UL Type 4X / 12, polyamide material, graphite fire penetration seal, E45 / EI30, intumescent performance, and strain relief.
For buyers searching for Ex Proof Cable Entry Frame in Dubai, this product offers strong value for oil & gas, petrochemical, refinery, automation, control panel, machine building, industrial enclosure, utility, factory, workshop, warehouse, port, process plant, skid, maintenance panel, and infrastructure applications. Its split frame design, ATEX suitability, secure grommet fixing, fire barrier performance, and sealed cable routing make it suitable for demanding hazardous-area cable entry systems.
Atex Hub supplies KEL-ER Series ATEX split cable entry frames and other hazardous-area cable entry systems globally across Dubai, UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide, helping industries source suitable Ex-rated cable entry and enclosure accessory products.