If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The ATEX Ex Aluminium Enclosure protects terminals, wiring connections, cable entries, instrument loops, control circuits, lighting circuits, and junction points in hazardous area installations. It provides a strong die-cast aluminium enclosure system for industrial sites where explosive gas, combustible dust, moisture, chemicals, impact, and outdoor exposure can affect electrical safety.
For companies looking for Ex Proof Aluminium Enclosure in Sharjah, this product offers a reliable solution for ATEX aluminium enclosures, explosion proof enclosures, ATEX enclosures, Ex proof enclosures, flame proof enclosures, hazardous area enclosures, and intrinsically safe enclosures. It supports safe terminal protection and cable termination in oil & gas, refinery, petrochemical, marine, chemical, power, automation, and industrial infrastructure projects.
Atex Hub supplies ATEX Ex Aluminium Enclosures globally across UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide, supporting hazardous area projects with certified Ex enclosure solutions.
An ATEX Ex Aluminium Enclosure is a hazardous area enclosure used to house terminals, electrical connections, cable entries, control wiring, instrumentation circuits, and junction points in explosive atmosphere locations. It protects internal components from dust, water, mechanical impact, and harsh industrial exposure while supporting certified Ex installation.
The reference product range includes standard and flange aluminium enclosures supplied as pre-assembled Ex terminal enclosures with approved terminal blocks, cable glands, and accessories for Ex ia intrinsically safe and Ex e increased safety zone applications. It also includes Ex component-certified empty enclosures for individual equipping.
The same reference lists a broad product range from 64 x 58 x 34 mm to 600 x 600 x 200 mm, and describes the aluminium Ex enclosures as suitable for aggressive environments and various climate zones because of their robust design.
Product Highlights:
The ATEX Ex Aluminium Enclosure helps contractors protect electrical terminals and cable connections in hazardous area projects. It supports safer wiring installation where flammable gases, vapours, combustible dust, moisture, outdoor conditions, and industrial impact can affect equipment.
Its die-cast aluminium body makes it useful where a strong metallic enclosure is needed with lighter weight than many stainless steel enclosures. This is useful for Sharjah Industrial Area, Hamriyah Free Zone, SAIF Zone, ports, workshops, warehouses, utilities, petrochemical facilities, and wider UAE industrial projects.
The reference product page lists product highlights including die-cast aluminium enclosure systems usable in all Ex areas, empty enclosures for individual fittings, Ex e / Ex ia junction boxes, optional window versions, and temperature classes T6 / T5 / T4.
An ATEX Ex Aluminium Enclosure protects terminal wiring and cable connections in hazardous locations. It supports safe cable management in process plants, oil and gas facilities, marine sites, utilities, power facilities, industrial zones, and infrastructure projects.
Industries use these enclosures across UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide. In Sharjah, they support industrial zones, ports, marine facilities, warehouses, utilities, factories, process plants, and infrastructure projects.
The technical details below help buyers choose the correct ATEX Ex Aluminium Enclosure. Always confirm the final certificate, Ex marking, enclosure size, terminals, cable gland type, ambient temperature, IP rating, and site classification before ordering.
| Specification | Details |
|---|---|
| Product Name | ATEX Ex Aluminium Enclosure |
| Product Category | ATEX Aluminium Enclosure / Hazardous Area Enclosure |
| Product Type | Ex Aluminium Terminal Enclosure / Ex Empty Enclosure / Ex ia Junction Box |
| Main Material | Die-cast aluminium AlSi 12 |
| Size Range | 64 x 58 x 34 mm to 600 x 600 x 200 mm |
| Main Configurations | Ex e terminal enclosure, Ex ia junction box, Ex empty enclosure |
| Protection Concepts | Ex eb, Ex ia, Ex db, Ex mb, Ex tb depending on final configuration |
| Gas Marking Option | II 2G Ex eb IIC T6/T5/T4 Gb |
| Intrinsic Safety Marking | II 2G Ex ia IIC T6/T5/T4 Gb |
| Mixed Protection Marking | II 2G Ex db eb ia [ia] mb IIC T6/T5/T4 Gb |
| Zone 2 / Category 3 Marking | II 3G Ex eb db mb ia [ia Ga] nA nC [op is] IIC T6/T5/T4 Gc |
| Dust Protection Marking | II 2D Ex tb IIIC T85°C/T100°C/T135°C Db IP66 |
| Temperature Classes | T6 / T5 / T4 |
| Dust Temperature Ratings | T85°C / T100°C / T135°C |
| Lid Screws | Tethered stainless-steel lid screws |
| Protective Conductor Connection | External stainless-steel protective conductor connection |
| Product Versions | Standard enclosure, flange enclosure, optional window version |
| Approvals Listed | ATEX, IECEx, INMETRO, EAC / TR CU, UL Ex, ABS, EXPLOLABS, CCOE India, UkrSEPRO Ukraine |
| Suitable Use | Terminal protection, junction wiring, lighting circuits, instrumentation loops, control connections |
| Supplier | Atex Hub |
| Supply Region | UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, Worldwide |
The aluminium Ex enclosure range includes multiple standard sizes. Exact size selection depends on terminal quantity, cable gland layout, cable bending radius, heat dissipation, temperature class, and maintenance access.
| Version | Article / Type Example | Height | Width | Depth |
|---|---|---|---|---|
| Ex e | 050606030 | 64 mm | 58 mm | 34 mm |
| Ex e | 050808060 | 80 mm | 75 mm | 57 mm |
| Ex e | 051010080 | 100 mm | 100 mm | 81 mm |
| Ex e | 051212090 | 120 mm | 122 mm | 91 mm |
| Ex e | 051616090 | 160 mm | 160 mm | 91 mm |
| Ex e | 052333180 | 230 mm | 330 mm | 181 mm |
| Ex e | 053140230 | 313 mm | 404 mm | 227 mm |
| Ex e | 056060200 | 600 mm | 600 mm | 202 mm |
| Ex ia | Matching family versions | Multiple sizes | Multiple sizes | Multiple sizes |
| Ex empty | Matching family versions | Multiple sizes | Multiple sizes | Multiple sizes |
The product range table lists Ex e sizes starting from 64 x 58 x 34 mm and extending up to approximately 600 x 600 x 202 mm, with matching Ex ia and Ex empty versions in the same enclosure family.
The correct ATEX Ex Aluminium Enclosure depends on the hazardous area classification, circuit type, cable gland size, terminal quantity, IP rating, temperature class, and certificate requirement. The enclosure body, terminals, cable glands, stopping plugs, and accessories must all match the site requirement.
| Selection Point | What to Check |
|---|---|
| Gas Zone | Confirm whether the site requires Zone 1 or Zone 2 protection |
| Dust Zone | Confirm whether the site requires Zone 21 or Zone 22 dust protection |
| Protection Type | Select Ex eb, Ex ia, Ex db, Ex mb, Ex tb, or mixed protection based on the final assembly |
| Material | Choose aluminium where a strong metallic enclosure with lighter weight is preferred |
| Cable Entries | Confirm thread type, gland size, cable diameter, and entry quantity |
| Terminals | Confirm terminal size, voltage, current, and earth terminal requirement |
| Internal Space | Keep enough space for wiring bend radius, terminal clearance, and maintenance access |
| Temperature Marking | Confirm T6, T5, T4, T85°C, T100°C, or T135°C based on project need |
| Certificate | Confirm ATEX, IECEx, UL Ex, INMETRO, or project-specific approval requirement |
| Environment | Check chemical, outdoor, marine, coastal, impact, and climate conditions |
The ATEX Ex Aluminium Enclosure can support different hazardous area protection concepts depending on the final certified configuration.
| Protection Type | Meaning | Common Use |
|---|---|---|
| Ex eb | Increased safety protection | Terminal connections, junction wiring, and control circuits |
| Ex ia | Intrinsic safety protection | Low-energy instrument loops, sensors, transmitters, alarms, and signal circuits |
| Ex db | Flameproof protection | Equipment designed to contain internal ignition under certified conditions |
| Ex mb | Encapsulation protection | Protected components sealed within compound |
| Ex tb | Dust protection by enclosure | Combustible dust hazardous areas |
| IP66 | Dust-tight and protected against powerful water jets | Outdoor, process, marine, and dusty industrial areas |
Many buyers use the term flame proof enclosure for all hazardous area enclosures. However, in Ex classification, Ex d flameproof and Ex e increased safety are different protection methods.
| Term | Meaning |
|---|---|
| Flame Proof / Ex d | Designed to contain an internal explosion and prevent flame transmission to the surrounding atmosphere |
| Ex e Increased Safety | Designed to prevent sparks, arcs, and excessive temperature during normal operation |
| Ex ia Intrinsic Safety | Limits electrical energy so sparks or heat cannot ignite the atmosphere under approved conditions |
| Ex tb Dust Protection | Prevents dust ignition risk through certified enclosure protection |
| ATEX Ex Aluminium Enclosure | Can be supplied in different Ex configurations depending on final approved assembly |
This distinction is important for Ex Proof Aluminium Enclosure in Sharjah projects because consultants, EPC contractors, and site inspectors may require a specific Ex protection type. Always confirm whether the project needs Ex d flameproof, Ex e increased safety, Ex ia intrinsic safety, or Ex tb dust protection before ordering.
An aluminium enclosure can support intrinsically safe circuit applications only when the final assembly uses approved Ex i components and follows the required wiring rules. The enclosure body alone does not make every circuit intrinsically safe.
For hazardous area projects involving Ex i circuits, check these points before final selection:
This helps the enclosure support safe wiring for instrument loops, sensors, transmitters, alarms, signal circuits, and low-energy control wiring.
Certifications help buyers choose the correct aluminium enclosure for hazardous area projects. The final enclosure must match the site zone, protection concept, terminal type, cable gland system, material, IP rating, temperature class, and project specification.
The reference product page lists approvals including ATEX, IECEx, INMETRO, EAC / TR CU, UL Ex, ABS, EXPLOLABS, CCOE India, and UkrSEPRO Ukraine.
Correct installation helps the ATEX Ex Aluminium Enclosure maintain hazardous area safety. The installer must check the certificate, Ex marking, terminal layout, cable entry design, wiring clearance, sealing, cover fixing, cable glands, and unused entries before energising the circuit.
Use trained personnel for hazardous area installation. Follow the project specification, certificate limits, manufacturer instructions, inspection requirements, and site area classification.
The ATEX Ex Aluminium Enclosure gives industries a compact, durable, and certified enclosure solution for hazardous area terminal and junction applications. It supports safe wiring, cable management, terminal protection, and long-term performance in demanding industrial sites.
For Sharjah projects, this enclosure suits oil & gas, petrochemical, refinery, chemical, marine, power, automation, process control, logistics, and infrastructure applications. Its die-cast aluminium construction, Ex e / Ex ia / Ex empty configuration options, Ex tb dust protection, and wide size range make it useful for hazardous area installations.
1. What is an ATEX Ex Aluminium Enclosure used for?
It protects terminals, wiring connections, cable entries, instrument loops, lighting circuits, and control connections in hazardous areas.
2. Is this suitable for Ex Proof Aluminium Enclosure in Sharjah projects?
Yes, it can suit Sharjah hazardous area projects when the Ex marking, certificate, terminal layout, cable entries, and site classification match the requirement.
3. What material is used?
The reference product range uses die-cast aluminium AlSi 12.
4. What size range is available?
The reference range lists sizes from 64 x 58 x 34 mm to 600 x 600 x 200 mm.
5. Can it support intrinsically safe circuits?
Yes, the enclosure family includes Ex ia versions for intrinsically safe applications when the final assembly is approved.
6. Can it support Ex e terminal applications?
Yes, the range includes pre-assembled Ex e increased safety terminal enclosures.
7. Can it be supplied empty?
Yes, the reference range includes Ex component-certified empty enclosures for individual equipping.
8. What dust protection marking is listed?
The reference page lists II 2D Ex tb IIIC T85°C/T100°C/T135°C Db IP66.
9. What approvals are listed?
The reference page lists approval options including ATEX, IECEx, INMETRO, EAC / TR CU, UL Ex, ABS, EXPLOLABS, CCOE India, and UkrSEPRO Ukraine.
10. Who supplies ATEX Ex Aluminium Enclosures globally?
Atex Hub supplies ATEX Ex Aluminium Enclosures across UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide.
The ATEX Ex Aluminium Enclosure gives industries a strong and certified aluminium enclosure solution for hazardous area terminal and field wiring protection. It helps protect terminals, cable entries, instrument loops, lighting circuits, and control wiring while supporting safer installation in explosive gas and dust environments.
For buyers searching for Ex Proof Aluminium Enclosure in Sharjah, this product offers strong value for oil & gas, petrochemical, refinery, chemical, marine, power, automation, logistics, and infrastructure projects. Its die-cast aluminium AlSi 12 construction, Ex e / Ex ia / Ex empty enclosure options, Ex tb dust protection, T6 / T5 / T4 temperature classes, and wide size range make it useful for demanding hazardous area applications.
Atex Hub supplies ATEX Ex Aluminium Enclosures globally across UAE, Saudi Arabia, Qatar, Oman, Kuwait, Bahrain, Europe, Africa, and worldwide, helping industries source safe and compliant hazardous area aluminium enclosure solutions for Ex installations.