If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The Atex Centrifugal Turret TCR is a purpose-built roof exhaust that moves air safely in hazardous gas and dust zones. Using an Ex-rated motor and a high-efficiency centrifugal impeller, it delivers strong airflow and stable pressure where standard fans can’t be used. A weather cowl, vertical discharge, and corrosion-resistant build protect the opening from rain, sand, and re-entrainment—ideal for hot rooftops in Dubai, dusty yards in Sharjah, and coastal plants in Abu Dhabi. Quick mounting, simple access for cleaning, and options for speed control make the Atex Turret in UAE a practical way to keep air quality in check, pass audits, and protect people and equipment—available locally at Atex Hub.
An Atex turret is a roof or wall exhaust unit designed to extract flammable vapours, fumes, and fine dust from classified areas without becoming an ignition source. The TCR model combines an Ex-certified motor with a centrifugal/mixed-flow impeller inside a weatherproof cowling that throws contaminated air upwards, away from nearby intakes. Unlike ordinary fans, the turret limits surface temperatures, manages electrical energy, and uses Ex-compatible cable entries to meet ATEX/IECEx rules. For the UAE’s climate—high ambient heat, airborne dust, and salt air—the TCR uses UV-stable finishes, marine-grade fasteners, and IP-rated sealing to keep ventilation reliable on analyser houses, battery rooms, solvent stores, and process buildings across Dubai, Sharjah, and Abu Dhabi.
Sites choose the TCR when they need reliable, compliant extraction that handles resistance from ducts and filters. Typical uses include hydrogen ventilation in battery-charging and UPS rooms, VOC and solvent removal from paint and mixing spaces, and dust control for powder handling and sack-tip stations. Plants also use the turret to maintain negative pressure in chemical dosing huts, analyser shelters, and skids, and to provide boost extraction during shutdowns, hot work, or confined-space operations. Because the discharge is vertical, the turret helps prevent contaminated air returning into nearby louvers—important for dense industrial clusters in Dubai and coastal corridors in Abu Dhabi.
Oil & Gas / Petrochemicals: Analyzer shelters, lube-oil rooms, tank farm cabinets, compressor ancillaries, solvent stores needing continuous Ex exhaust.
Marine & Ports: Pump rooms, paint shops, and dockside stores where spray, vibration, and salt air demand sealed, corrosion-resistant construction.
Utilities & Water: Chlorination rooms and chemical dosing huts that require constant fume removal with safe electrics.
Food, Pharma & Chemical: Powder rooms and solvent prep areas where washable surfaces and contained airflow matter.
Battery Rooms & Workshops: Hydrogen management for forklift/UPS chargers and maintenance bays in classified zones across the UAE.
Choose the TCR for safety, airflow performance, and low life-cycle cost. The centrifugal impeller generates strong pressure for ductwork and filters while keeping sound levels manageable. Housings and hardware are specified for UV, dust, and coastal corrosion, and motor options match common UAE voltages. Installation is straightforward with standard roof curbs, Ex glands, and simple wiring. Add VFD-ready motors, airflow switches, and backdraft features to tune ventilation to real conditions. With Atex Hub support in the UAE, you’ll match the duty point (m³/h @ Pa), Ex code, and controls to your process—so commissioning is faster and audits are smoother in Dubai, Sharjah, and Abu Dhabi.
| Item | Specification |
|---|---|
| Model | Atex Centrifugal Turret – TCR Series |
| Airflow Range | Approx. 1,000 – 20,000 m³/h (size & duty dependent) |
| Static Pressure | Up to 800 Pa (model dependent) |
| Protection Concept | ATEX/IECEx aligned; Ex motor options for gas/dust zones (final Ex code on nameplate) |
| Motor Options | 2-pole / 4-pole IE2/IE3, 50/60 Hz, 230/400/690 V AC (variant dependent) |
| Materials | Powder-coated steel or 316 stainless steel cowl; aluminium/PP anti-spark impeller |
| Ingress Protection | Turret/entries IP55–IP66 (installation dependent) |
| Operating Temperature | −20 °C to +55 °C continuous (higher by request & Ex class) |
| Discharge | Vertical, weather-protected; ingress/bird guard |
| Mounting | Roof curb / flange plate; wall plinth option; vibration pads |
| Controls | DOL / Star-Delta; VFD with Ex-rated motor (verify compatibility), airflow switch option |
| Noise (Free Field) | 58–78 dB(A) @ 3 m typical (size & duty dependent) |
| Duct Interfaces | Round/rectangular adaptors; backdraft damper / non-return options |
| Cable Entries | Metric/NPT Ex glands; internal earth points |
| Compliance | ATEX/IECEx, IEC 60079 explosive atmospheres; IEC 60529 IP; ISO 5801 performance test |
| Maintenance | Access panel for cleaning; sealed or grease-for-life bearings (model dependent) |
1) Why choose a centrifugal turret over an axial roof fan?
Centrifugal impellers provide higher static pressure, which is better for ducted runs, filters, and long paths common on industrial UAE sites.
2) Can I control speed with a VFD?
Yes—when paired with a VFD-ready Ex motor and correct cabling/filters. This enables night-setback and boost modes to save energy.
3) How do I size the TCR?
Share room volume, target ACH, contaminant type, and estimated duct losses. We’ll select a duty point (m³/h @ Pa) that meets process and code needs.
4) Is it suited for coastal installations in Abu Dhabi or Dubai?
Yes—specify 316 stainless cowl, marine coatings, and IP66 entries to maximise life in salt-spray environments.
5) What about hydrogen in battery rooms?
Use continuous low-speed extraction with alarm-driven boost, linked to hydrogen detectors and your F&G logic.
6) What maintenance is recommended?
Periodically clean the cowl/impeller, check gland torque and fixings, and verify airflow switch or DP sensor set-points during PM rounds.
7) Can the turret be wall-mounted?
Roof mounting is standard, but wall plinth versions exist. Confirm discharge direction, weather protection, and airflow path before selection.
For safe, dependable ventilation in classified areas, the Atex Centrifugal Turret TCR offers the airflow, compliance, and durability your facility needs. Engineered for the UAE climate and available at Atex Hub, it simplifies specification, speeds installation, and keeps air quality under control across Dubai, Sharjah, and Abu Dhabi. When ventilation is mission-critical, choose the Atex Turret in UAE that is built for hazardous areas.