PRE-SALES

If you have any questions before making a purchase chat with our online operators to get more information.

Ask An Expert

AFTER-SALES

If you have need any help about the After-Sales issues, please contact us.

Contact Us
ATEX Plug & Socket in Bahrain | Ex Proof Plug & Socket in Bahrain

Explosion Proof Receptacle Explosion Proof Socket and Plug SSP-P Series

0 People Visited 8 hours Spent
Buy ATEX Plug & Socket in Bahrain for Zone 1, 2, 21 & 22 hazardous areas. Atex Hub supplies SSP-P explosion proof plugs and sockets across UAE, Saudi, Qatar, Oman & Kuwait.
Brand: Other
Tags: ATEX Plug & Socket in Africa, ATEX Plug & Socket in Bahrain, ATEX Plug & Socket in Europe, ATEX Plug & Socket in Kuwait, ATEX Plug & Socket in Oman, ATEX Plug & Socket in Qatar, ATEX Plug & Socket in Saudi Arabia, ATEX Plug & Socket in UAE, ATEX Plug & Socket Worldwide, ATEX Plugs and Sockets in Africa, ATEX Plugs and Sockets in Bahrain, ATEX Plugs and Sockets in Europe, ATEX Plugs and Sockets in Kuwait, ATEX Plugs and Sockets in Oman, ATEX Plugs and Sockets in Qatar, ATEX Plugs and Sockets in Saudi Arabia, ATEX Plugs and Sockets in UAE, ATEX Plugs and Sockets Worldwide, Ex Proof Plug and Socket in Africa, Ex Proof Plug and Socket in Bahrain, Ex Proof Plug and Socket in Europe, Ex Proof Plug and Socket in Kuwait, Ex Proof Plug and Socket in Oman, Ex Proof Plug and Socket in Qatar, Ex Proof Plug and Socket in Saudi Arabia, Ex Proof Plug and Socket in UAE, Ex Proof Plug and Socket Worldwide, Explosion Proof Plugs and Sockets in Africa, Explosion Proof Plugs and Sockets in Bahrain, Explosion Proof Plugs and Sockets in Europe, Explosion Proof Plugs and Sockets in Kuwait, Explosion Proof Plugs and Sockets in Oman, Explosion Proof Plugs and Sockets in Qatar, Explosion Proof Plugs and Sockets in Saudi Arabia, Explosion Proof Plugs and Sockets in UAE, Explosion Proof Plugs and Sockets Worldwide, Flameproof Plug and Socket in Africa, Flameproof Plug and Socket in Bahrain, Flameproof Plug and Socket in Europe, Flameproof Plug and Socket in Kuwait, Flameproof Plug and Socket in Oman, Flameproof Plug and Socket in Qatar, Flameproof Plug and Socket in Saudi Arabia, Flameproof Plug and Socket in UAE, Flameproof Plug and Socket Worldwide, Hazardous Area Plugs and Sockets in Africa, Hazardous Area Plugs and Sockets in Bahrain, Hazardous Area Plugs and Sockets in Europe, Hazardous Area Plugs and Sockets in Kuwait, Hazardous Area Plugs and Sockets in Oman, Hazardous Area Plugs and Sockets in Qatar, Hazardous Area Plugs and Sockets in Saudi Arabia, Hazardous Area Plugs and Sockets in UAE, Hazardous Area Plugs and Sockets Worldwide, Intrinsically Safe Plug and Socket in Africa, Intrinsically Safe Plug and Socket in Bahrain, Intrinsically Safe Plug and Socket in Europe, Intrinsically Safe Plug and Socket in Kuwait, Intrinsically Safe Plug and Socket in Oman, Intrinsically Safe Plug and Socket in Qatar, Intrinsically Safe Plug and Socket in Saudi Arabia, Intrinsically Safe Plug and Socket in UAE, Intrinsically Safe Plug and Socket Worldwide

Product Details

ATEX Plug & Socket in Bahrain | Ex Proof Plug & Socket in Bahrain


The Explosion Proof Receptacle Explosion Proof Socket and Plug SSP-P Series gives industries a safe plug-and-socket connection system for hazardous gas and dust areas. It supports fixed and portable electrical equipment during maintenance, plant turnarounds, field operation, shutdown work, power distribution, and hazardous-area service connections.

For companies searching for ATEX Plug & Socket in Bahrain, this product suits ATEX plug & socket, ATEX plugs and sockets, explosion proof plugs and sockets, hazardous area plugs and sockets, intrinsically safe plug and socket, Ex proof plug and socket, and flameproof plug and socket requirements. It works well in oil & gas plants, refineries, petrochemical units, chemical plants, marine areas, ports, utilities, factories, workshops, warehouses, process skids, maintenance areas, and industrial field equipment.

Atex Hub supplies ATEX plugs and sockets globally across Bahrain, UAE, Saudi Arabia, Qatar, Oman, Kuwait, Europe, Africa, and worldwide, helping industries source safe and certified hazardous-area electrical connection products.

What Is Explosion Proof Receptacle Explosion Proof Socket and Plug SSP-P Series?

The Explosion Proof Receptacle Explosion Proof Socket and Plug SSP-P Series is an explosion-protected receptacle, socket, and plug system for hazardous industrial locations. It provides a safe connection point for fixed or portable electrical equipment used during maintenance, shutdowns, and plant turnarounds.

The SSP-P Series supports Zone 1, Zone 2, Zone 21, and Zone 22 hazardous areas, along with Class I Division 2 Groups A, B, C, D, Class II Division 1 Groups E, F, G, and Class III area classifications. It carries Type 4X / IP66 protection and supports Ex d e IIC T6 Gb gas protection and Ex tb IIIC T80°C Db IP66 dust protection.

The product uses glass fibre-reinforced polyester resin housing for both receptacle and plug. It supports 16 A, 32 A, 63 A, and 125 A current ratings and multiple rated voltage ranges, including 600–690 V AC, 480–500 V AC, 380–415 V AC, 200–250 V AC, 100–130 V AC, DC 24 V, and DC 36 V.

Key Features of ATEX Plug & Socket

The SSP-P Series explosion proof receptacle and plug system gives industrial teams a rugged and safe electrical connection point for hazardous environments. It supports safe plug-in operation, correct voltage matching, wet-location use, and high-current industrial power connection.

  • Ideal for ATEX Plug & Socket in Bahrain
  • Suitable for ATEX Plugs and Sockets
  • Supports Explosion Proof Plugs and Sockets
  • Works as Hazardous Area Plugs and Sockets
  • Can support Intrinsically Safe Plug and Socket circuits when selected within approved low-energy Ex i systems
  • Suitable for Ex Proof Plug and Socket requirements
  • Suitable for Flameproof Plug and Socket applications
  • Product series: SSP-P Series
  • Product type: explosion proof receptacle, socket and plug
  • Hazardous area suitability: Zone 1, Zone 2, Zone 21, Zone 22
  • NEC classification: Class I Division 2 Groups A, B, C, D
  • Dust classification: Class II Division 1 Groups E, F, G
  • Additional classification: Class III
  • Gas Ex marking: Ex d e IIC T6 Gb
  • Dust Ex marking: Ex tb IIIC T80°C Db IP66
  • Current ratings: 16 A, 32 A, 63 A, 125 A
  • Protection: Type 4X, IP66, wet locations
  • Housing material: glass fibre-reinforced polyester resin, black
  • Same colour for socket and matching plug helps avoid plug-in mistakes

The SSP-P Series uses matching socket and plug colours to help reduce wrong plug-in selection, and its glass-reinforced plastic housing supports different sizes for 16 A, 32 A, 63 A, and 125 A ratings.

Applications of Explosion Proof Plugs and Sockets

The Explosion Proof Receptacle Explosion Proof Socket and Plug SSP-P Series helps industries create safe electrical connection points in hazardous gas and dust areas. It suits applications where normal plugs and sockets can create ignition risks, water ingress problems, loose connection issues, or wrong mating risks.

  • Oil & Gas Facilities – Teams use ATEX plug and socket systems for portable equipment, field maintenance, pump areas, process skids, and hazardous-area power points.
  • Refineries – Operators use explosion proof plugs and sockets during shutdowns, turnarounds, maintenance work, process unit servicing, and equipment connection.
  • Petrochemical Plants – The SSP-P Series supports safe electrical connection where gas, vapour, chemicals, and flammable atmospheres may exist.
  • Chemical and Pharmaceutical Areas – Hazardous area plugs and sockets help connect equipment in chemical handling, process rooms, maintenance zones, and service areas.
  • Marine and Ports – The Type 4X / IP66 protection supports wet, corrosive, outdoor, and coastal industrial areas when the full installation uses suitable accessories.
  • Mining and Metal Industries – The plug and socket system supports equipment connection in dust-prone, heavy-duty, and rugged industrial environments.
  • Industrial Manufacturing – Teams use Ex proof plug and socket systems for machines, tools, test equipment, service points, and field power distribution.
  • Warehouses and Utility Areas – The product supports electrical connection points where hazardous gases, dusts, or wet-location requirements may apply.
  • Portable and Fixed Equipment – The receptacle can connect fixed or portable electrical equipment during maintenance and plant turnarounds.
  • Bahrain Industrial Projects – It suits Manama, Sitra, Hidd, Riffa, Muharraq, Bahrain International Investment Park, ports, utilities, factories, workshops, marine areas, and infrastructure projects.

Technical Specifications

SpecificationDetails
Product NameExplosion Proof Receptacle Explosion Proof Socket and Plug SSP-P Series
Product TypeATEX / Explosion Proof Plug and Socket / Receptacle System
SeriesSSP-P Series
Hazardous Area ZonesZone 1, Zone 2, Zone 21, Zone 22
NEC Area ClassificationClass I Division 2 Groups A, B, C, D
Dust Area ClassificationClass II Division 1 Groups E, F, G
Additional ClassificationClass III
Gas Ex MarkingEx d e IIC T6 Gb
Dust Ex MarkingEx tb IIIC T80°C Db IP66
EU Gas MarkingII 2 G Ex d e IIC T6 Gb
EU Dust MarkingII 2 D Ex tb IIIC T80°C Db IP66
Rated Current16 A, 32 A, 63 A, 125 A
Rated Voltage600–690 V AC, 480–500 V AC, 380–415 V AC, 200–250 V AC, 100–130 V AC, DC 24 V, DC 36 V
IP GradeWet locations, Type 4X, IP66
Ambient Temperature-40°C to +55°C / -40°F to +131°F
Housing MaterialGlass fibre-reinforced polyester resin, black
Cable EntryMetric standard or NPT thread plugs / cable glands
Pole Options2P, 3P, 2P+PE, 1P+N+PE, 4P, 3P+PE, 5P, 3P+N+PE
Compliance StandardsIEC 60079-0, IEC 60079-7, IEC 60079-11, IEC 60079-31, EN 60079-0, EN 60079-7, EN 60079-11, EN 60079-31
Other StandardsUL 844, UL 1598, UL 1598A, CSA C22.2 No.137
SupplierAtex Hub

The SSP-P Series supports IEC 60079-0, IEC 60079-7, IEC 60079-11, IEC 60079-31, and corresponding EN 60079 standards, along with UL 844, UL 1598, UL 1598A, and CSA C22.2 No.137 standard references.

Available Current and Pole Configurations

The SSP-P Series supports multiple current ratings, voltage ranges, and pole configurations. This helps project teams select the correct plug and socket based on load, voltage, phase arrangement, site standard, and equipment type.

  • 16 A Versions – Suitable for smaller hazardous-area equipment, portable tools, service points, and low-to-medium power circuits.
  • 32 A Versions – Suitable for industrial equipment, maintenance systems, workshop power points, and field machinery.
  • 63 A Versions – Useful for heavier plant equipment, process skids, larger portable systems, and temporary power distribution.
  • 125 A Versions – Supports high-current hazardous-area connection where the site needs stronger plug and socket capacity.
  • 2P / 3P Options – Support selected power and control circuit arrangements.
  • 2P+PE / 1P+N+PE Options – Support single-phase or protected conductor layouts.
  • 3P+PE / 3P+N+PE Options – Support three-phase industrial equipment where protective earth or neutral arrangements apply.
  • AC and DC Voltage Options – Support a wide range of electrical systems from DC 24 V up to 600–690 V AC.

Hazardous Area Selection Guide

The correct ATEX plug & socket depends on hazardous zone, current rating, voltage, pole configuration, cable entry, ingress protection, ambient temperature, and site certification requirement.

Selection PointWhat to Check
Hazardous ZoneConfirm Zone 1, Zone 2, Zone 21, or Zone 22 requirement
Area ClassificationCheck Class I Div. 2, Class II Div. 1, or Class III if the project uses NEC classification
Current RatingSelect 16 A, 32 A, 63 A, or 125 A based on connected load
Voltage RatingMatch the circuit with the correct AC or DC voltage range
Pole ConfigurationChoose 2P, 3P, 4P, 5P, PE, N, or 3P+N+PE layout according to circuit design
Ingress ProtectionConfirm Type 4X / IP66 for wet, dusty, and outdoor areas
Housing MaterialUse glass fibre-reinforced polyester resin where corrosion and impact resistance matter
Cable EntryConfirm metric, NPT, plug, or cable gland requirement
Ambient TemperatureConfirm -40°C to +55°C site condition
ComplianceConfirm datasheet, Ex marking, voltage, current, plug colour, and site classification before procurement

Why Colour-Matched Plug and Socket Design Matters

Colour matching helps field teams select the correct plug and socket combination. In hazardous areas, wrong mating can create downtime, electrical faults, unsafe connections, and equipment damage.

The SSP-P Series uses the same colour for socket and matching plug to help reduce plug-in mistakes. This makes the system useful during plant turnarounds, shift work, maintenance jobs, and temporary power use where operators may handle multiple voltage and current combinations.

Why Type 4X and IP66 Protection Matter

Hazardous-area plugs and sockets often face dust, water spray, washdown, humidity, salt air, outdoor exposure, and industrial contamination. Type 4X / IP66 protection helps support use in wet locations, corrosive atmospheres, and dusty environments.

This matters in Bahrain industrial areas near ports, marine facilities, petrochemical plants, refineries, workshops, utilities, and infrastructure projects. The final installation should maintain proper cable entry, sealing, mounting, and inspection to keep the required protection level.

Why High Current Options Matter

Industrial plants use different electrical loads. Some applications need small service sockets, while other applications need high-current power points for larger portable equipment and temporary systems. The SSP-P Series supports 16 A, 32 A, 63 A, and 125 A, which helps project teams use one plug and socket family across multiple load categories.

This range supports easier specification for maintenance teams, EPC contractors, panel builders, and plant engineers working on hazardous-area electrical systems.

ATEX, Explosion Proof, Ex Proof and Intrinsically Safe Plug & Socket Guide

Many buyers use ATEX plug & socket, ATEX plugs and sockets, explosion proof plugs and sockets, hazardous area plugs and sockets, intrinsically safe plug and socket, Ex proof plug and socket, and flameproof plug and socket together. However, each term can describe a different hazardous-area protection method or electrical connection type.

TermMeaning
ATEX Plug & SocketPlug and socket selected for explosive atmosphere installations
Explosion Proof Plugs and SocketsPlug and socket systems used in Ex-rated hazardous-area circuits
Hazardous Area Plugs and SocketsConnection devices used in classified gas or dust areas
Intrinsically Safe Plug and SocketPlug and socket used with approved low-energy Ex i circuits
Ex Proof Plug and SocketCommon term for Ex-rated plug and socket used in hazardous areas
Flameproof Plug and SocketPlug and socket selected for flameproof or Ex-rated electrical connection
Explosion Proof ReceptacleFixed socket outlet used for hazardous-area electrical connection
Type 4X Plug and SocketPlug and socket assembly designed for wet and corrosive locations

This difference matters in Bahrain projects because consultants, EPC contractors, safety teams, and inspectors may ask for a specific protection method. Always confirm whether the project needs ATEX, IECEx-style Zone classification, NEC Division classification, Ex d e IIC, Ex tb IIIC, Type 4X, IP66, or intrinsically safe circuit selection.

Installation & Usage Notes

Correct installation helps the Explosion Proof Receptacle Explosion Proof Socket and Plug SSP-P Series perform safely and reliably. The installer must check the hazardous area, current rating, voltage, pole arrangement, cable entry, colour coding, enclosure protection, and site approval before commissioning.

  • Select the correct ATEX plug & socket based on the site classification.
  • Confirm whether the area falls under Zone 1, Zone 2, Zone 21, or Zone 22.
  • Match the current rating with the load: 16 A, 32 A, 63 A, or 125 A.
  • Match the voltage with the approved AC or DC voltage range.
  • Select the correct pole configuration based on the circuit design.
  • Use matching plug and socket colours to avoid connection errors.
  • Maintain Type 4X / IP66 protection during installation.
  • Use correct metric or NPT cable entry, plugs, glands, and seals.
  • Do not connect incompatible plugs and sockets.
  • Inspect housing, seals, contacts, cable entries, plug fit, labels, locking condition, and earth continuity during maintenance.
  • Test continuity, insulation resistance, mating quality, sealing, and safe operation before handover.

Certifications, Standards & Compliance

Certifications help buyers select the correct hazardous-area plug and socket. The final product must match the hazardous zone, circuit voltage, current rating, pole layout, cable entry, ingress protection, temperature class, and inspection standard.

The SSP-P Series supports gas marking Ex d e IIC T6 Gb and dust marking Ex tb IIIC T80°C Db IP66. It supports Zone 1, Zone 2, Zone 21, and Zone 22 area selection and Class I Division 2, Class II Division 1, and Class III area classifications.

  • ATEX Certification – Supports equipment selection for explosive atmosphere installations.
  • IECEx – Confirm IECEx documentation when the project follows international hazardous-area certification rules.
  • IEC 60079 Series – Supports explosive atmosphere equipment design and testing requirements.
  • EN 60079 Series – Supports European hazardous-area equipment standards.
  • UL 844 – Supports luminaires and related equipment for hazardous classified locations where applicable to project scope.
  • CSA C22.2 No.137 – Supports electric luminaires for hazardous locations where applicable to project scope.
  • Type 4X / IP66 – Supports wet-location and outdoor industrial applications.
  • Project Compliance Check – Always confirm datasheet, certificate, Ex marking, current, voltage, pole layout, and site classification before procurement.

Why Choose This Hazardous Area Plug and Socket

The Explosion Proof Receptacle Explosion Proof Socket and Plug SSP-P Series gives industries a flexible and rugged connection system for hazardous gas and dust areas. It supports 16 A, 32 A, 63 A, and 125 A ratings, wide AC and DC voltage options, Type 4X / IP66 protection, glass fibre-reinforced polyester resin housing, and gas / dust Ex markings.

For Bahrain projects, this plug and socket suits oil & gas, petrochemical, refinery, chemical, marine, port, utility, power, automation, factory, warehouse, workshop, skid, machinery, service point, temporary power, and infrastructure applications. Its Zone 1 / 2 / 21 / 22 suitability, Ex d e IIC T6 Gb gas protection, Ex tb IIIC T80°C Db dust protection, and same-colour plug-and-socket selection make it useful for demanding hazardous-area electrical connection systems.

  • Ideal for ATEX Plug & Socket in Bahrain
  • Suitable for ATEX Plugs and Sockets
  • Supports Explosion Proof Plugs and Sockets
  • Works as Hazardous Area Plugs and Sockets
  • Can support Intrinsically Safe Plug and Socket applications when used within approved Ex i circuits
  • Suitable for Ex Proof Plug and Socket
  • Suitable for Flameproof Plug and Socket requirements
  • Useful for fixed and portable electrical equipment during maintenance and turnarounds
  • Supplied globally by Atex Hub

Frequently Asked Questions

1. What is Explosion Proof Receptacle Explosion Proof Socket and Plug SSP-P Series used for?
It provides safe plug-and-socket connection for fixed and portable electrical equipment in hazardous gas and dust areas.

2. Is this suitable for ATEX Plug & Socket in Bahrain projects?
Yes, it can suit Bahrain hazardous-area projects when the zone, current, voltage, pole layout, Ex marking, and site approval match the requirement.

3. Which hazardous zones does SSP-P Series support?
It supports Zone 1, Zone 2, Zone 21, and Zone 22 hazardous areas.

4. What current ratings are available?
The product supports 16 A, 32 A, 63 A, and 125 A current ratings.

5. What protection rating does it offer?
The SSP-P Series supports wet locations, Type 4X, and IP66 protection.

6. What housing material does it use?
It uses glass fibre-reinforced polyester resin housing in black colour.

7. What gas and dust Ex markings does it support?
It supports Ex d e IIC T6 Gb for gas and Ex tb IIIC T80°C Db IP66 for dust areas.

8. What ambient temperature range does it support?
The product supports -40°C to +55°C / -40°F to +131°F ambient temperature range.

9. Where can it be used in Bahrain?
It suits Manama, Sitra, Hidd, Riffa, Muharraq, Bahrain International Investment Park, ports, utilities, factories, workshops, marine areas, and infrastructure sites.

10. Who supplies ATEX plugs and sockets globally?
Atex Hub supplies ATEX plugs and sockets across Bahrain, UAE, Saudi Arabia, Qatar, Oman, Kuwait, Europe, Africa, and worldwide.

Conclusion

The Explosion Proof Receptacle Explosion Proof Socket and Plug SSP-P Series gives industries a safe and flexible plug-and-socket connection system for hazardous gas and dust areas. It supports Zone 1, Zone 2, Zone 21, and Zone 22 applications, 16 A to 125 A current ratings, wide AC and DC voltage ranges, Type 4X / IP66 protection, and glass fibre-reinforced polyester resin housing.

For buyers searching for ATEX Plug & Socket in Bahrain, this product offers strong value for oil & gas, petrochemical, refinery, chemical, marine, port, utility, factory, workshop, temporary power, plant turnaround, fixed equipment, portable equipment, and infrastructure applications. Its Ex d e IIC T6 Gb gas protection, Ex tb IIIC T80°C Db IP66 dust protection, same-colour plug and socket matching, and multiple pole configurations make it suitable for demanding hazardous-area electrical connection systems.

Atex Hub supplies SSP-P Series explosion proof receptacles, sockets, plugs, and other ATEX plug and socket solutions globally across Bahrain, UAE, Saudi Arabia, Qatar, Oman, Kuwait, Europe, Africa, and worldwide, helping industries source safe and compliant Ex-rated electrical connection products.

Have Questions?

Ask The Fashion Expert Anything On Ella

We will follow up with you via email within 24-36 hours

Please answer the following questionnaire

Size Chart

Halo Size Chart

Lamcorper Ostique Amattis

30 reviews
15 sold in last 15 hours
Brand: Mango
Product Code: MKI-2661
Availability: Many In Stock
Nam tempus turpis at metus scelerisque placerat nulla deumantos solicitud felis. Pellentesque diam dolor, elementum etos lobortis des mollis ut risus. Sedcus vitas scelerisque faucibus...
Color: Pink
Size: XS
99 customers are viewing this product
  • Ella security
  • Ella security
  • Ella security
  • Ella security
Product Image
Product Image
Product Image
Product Image
Product Image
Zoom the image with mouse

Recently Viewed

Sorry, there are no products.
Recently Viewed Products
Back To Top

Notify Me

(Product 4) Sample - Clothing And Accessory Boutiques For Sale
Color: Pink
Size: XS
Material: Option 1
Menu
Login

Your Cart

0 items