If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The EXHEAT HEWL/HEOL Line Heaters , robust Atex line heaters built for precise, safe heating of liquids and gases directly in the pipeline. Engineered for hazardous areas and proven across the UAE, these inline, circulation-style heaters deliver rapid heat transfer with tight temperature control for facilities in Dubai, Abu Dhabi, and Sharjah. Whether you need an inline air heater, a line heater for hydrocarbon liquids, or a circulation heater for process water and chemicals, EXHEAT’s HEWL/HEOL ranges provide dependable performance with ATEX/IECEx-certified safety. Supplied by Atex-focused specialists, they integrate quickly, run efficiently, and simplify maintenance—helping you improve uptime and energy use in demanding Gulf conditions.
An Atex line heater (also called an inline circulation heater) warms a flowing medium—oil, water, chemicals, air, or gas—while it moves through a pressure-rated vessel containing immersed electric elements. Unlike tank-based systems, EXHEAT HEWL/HEOL Line Heaters apply heat exactly where it’s needed, cutting losses and improving response time. The electrical terminal housing uses flameproof (Ex d) or increased safety (Ex e) protection, so any internal fault remains contained and cannot ignite the surrounding atmosphere. For Dubai terminals, Abu Dhabi refineries, and Sharjah industrial zones, this design offers compact installation, fast heat-up, and assured compliance.
Process preheat and temperature maintenance: Keep diesel, crude, and lube oils pumpable, stabilize chemical feed streams, or preheat air/gas to avoid hydrate or wax formation before metering and separation. Condensation and frost prevention: Maintain a minimum line temperature in exposed pipe runs and analyser lines. Start-up assistance: Bring systems to operating temperature quickly after shutdowns. These are everyday requirements in Dubai coastal plants, Abu Dhabi offshore modules, and Sharjah industrial estates.
Oil & Gas / Petrochemical: Fuel conditioning skids, wellhead gas preheat, separator inlet heating, flare purge air preheat.
Chemical & Industrial: Solvent and polymer stream heating, CIP/cleaning bath recirculation, reactor feed stability.
Marine & Terminals: Bunkering lines, day-tank loops, HVAC/process inline air heater duties.
Utilities & Power: Water/glycol loops, lube oil systems, turbine auxiliary fluid heating.
Water & Wastewater: Sludge and process water preheat for consistent plant performance across the UAE.
Certified for hazardous areas: ATEX/IECEx compliance for Zone 1/2 (gas) and (variant dependent) Zone 21/22 (dust).
High efficiency, compact footprint: Direct immersion elements deliver rapid heat transfer with minimal losses.
Built for Gulf environments: IP66/67 terminal enclosures and corrosion-resistant metallurgy stand up to dust, salt spray, and heat.
Easy integration & control: Straightforward piping tie-ins, RTD/thermostat options, and PLC/DCS-ready signals.
Service-friendly: Modular element bundles and accessible housings reduce downtime during inspection or change-out.
Backed locally: Sizing support, documentation, and supply coverage for Dubai, Abu Dhabi, and Sharjah.
| Item | Detail |
|---|---|
| Product Name | EXHEAT HEWL/HEOL Line Heaters |
| Heater Style | Inline circulation (line) heater with immersion bundle |
| Certification | ATEX / IECEx (gas and/or dust variants) |
| Zones | Gas: Zone 1 / Zone 2; Dust: Zone 21 / Zone 22 (model dependent) |
| Typical Power Range | 1 kW – 500 kW (custom to duty) |
| Voltage / Phases | 230/400/415/690 VAC, 1-ph or 3-ph, 50/60 Hz |
| Pressure Vessel | Code-built shell sized to design pressure/temperature |
| Wetted Materials | SS316/316L, Incoloy 800/825, Inconel, others to suit medium |
| Terminal Enclosure | Ex d (flameproof) and/or Ex e (increased safety) |
| Ingress Protection | IP66 / IP67 (IEC 60529) |
| Temperature Class | T3 / T4 (per design & surface limit) |
| Sensing & Control | PT100/RTD, thermowell, high-temp cut-out; optional SCR/thyristor control |
| Mounting | Inline spool with flanged ends for pipeline tie-in |
| Media | Oil, water/glycol, chemicals, air, natural gas |
| Documentation | Datasheet, wiring diagram, test reports, nameplate, ATEX/IECEx certs |
ATEX Directive 2014/34/EU – equipment for explosive atmospheres
IECEx Scheme – international certification for Ex equipment
EN 60079-0 – Explosive atmospheres: General requirements
EN 60079-1 – Protection by flameproof enclosure “d”
EN 60079-7 – Increased safety “e”
IEC 60529 – IP ratings (IP66/IP67)
1) Where are HEWL/HEOL line heaters typically used in Dubai?
In fuel conditioning, gas preheat, separator inlet heating, and inline air heater duties on skids across refineries, terminals, and marine facilities.
2) Are HEWL/HEOL models ATEX approved for gas and dust?
Yes—models are available with ATEX/IECEx approvals for Zone 1/2 and (variant dependent) Zone 21/22.
3) What materials should I choose for Abu Dhabi offshore use?
Commonly SS316L or Incoloy for saline, corrosive environments; final choice depends on medium, temperature, and chloride content.
4) Can the heater be controlled from our PLC/DCS in Sharjah plants?
Absolutely—use RTD/thermocouple inputs with SCR/thyristor power control and high-temperature cut-outs for safe, precise regulation.
5) What information do you need to size an Atex line heater?
Flow rate, inlet/outlet temperatures, pressure, medium properties, allowable pressure drop, utilities, and zone classification.
6) Is maintenance complicated?
No—modular element bundles and accessible enclosures make inspection and replacement straightforward during scheduled outages.
7) Do you supply documentation for safety files across the UAE?
Yes—expect certificates, Doc, test/inspection reports, wiring diagrams, and nameplate data with the supply.
If your project in Dubai, Abu Dhabi, or Sharjah needs compact, efficient, and certified Atex Line Heaters, the EXHEAT HEWL/HEOL series is a proven choice. Designed for reliable inline heating of oil, gas, water, air, and chemicals, these units pair ATEX/IECEx safety with high thermal efficiency and easy integration. With local support and documentation, they help UAE facilities boost uptime, cut energy losses, and stay compliant—without complicating your process design. Available at Atex Hub.