

If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The EXHEAT Hazardous Area Immersion Heaters are high-performance, Atex-certified electric heaters engineered for safe and efficient heating in hazardous environments. Designed to meet the rigorous demands of oil & gas, chemical, marine, and industrial sectors in Dubai, these heaters ensure reliable operation even in Zone 1, Zone 2, Zone 21, and Zone 22 classified areas. Built by EXHEAT, a trusted global brand, these heaters combine advanced safety features with robust engineering for continuous performance under extreme UAE conditions.
An Atex Immersion Heater is an electric heating device installed directly into tanks, vessels, or pipelines to heat liquids such as water, oil, or chemicals. Unlike conventional water heater rods or immersion elements, these heaters are certified for hazardous areas, ensuring that no ignition or spark occurs during operation.
The EXHEAT Hazardous Area Immersion Heater uses high-grade flanged or screw-plug designs fitted with flameproof (Ex d) or increased safety (Ex e) terminal enclosures. Each heater delivers direct, efficient heating with precise temperature control—making it a reliable solution for Dubai’s industrial, marine, and refinery operations where safety and uptime are essential.
ATEX and IECEx Certified: Fully compliant for use in explosive gas (Zone 1/2) and dust (Zone 21/22) atmospheres.
High Efficiency: Direct immersion heating ensures minimal heat loss and fast temperature rise.
Durable Construction: Built with SS316L, Incoloy, or Inconel for long service life in corrosive environments.
Precise Temperature Control: Equipped with thermostats, RTDs, or thermocouples for accurate monitoring.
Weatherproof Protection: IP66/IP67 housing ideal for outdoor or marine use in Dubai and the wider UAE.
Customizable Design: Available in flanged, threaded, or insertion configurations to suit different tanks or vessels.
Safe Operation: Explosion-proof terminal enclosure prevents ignition and ensures safe performance in hazardous areas.
The EXHEAT Hazardous Area Immersion Heaters are widely used across multiple sectors in Dubai, Abu Dhabi, and Sharjah:
Oil & Gas Industry: Heating crude oil, diesel, or lubricants for smooth pumping and flow control.
Chemical Processing Plants: Maintaining ideal temperatures for chemical reactions and fluid transfers.
Marine & Offshore Platforms: Safe heating of ballast water, process fluids, and cleaning systems.
Power Plants & Utilities: Preheating boiler feed water, fuel oil, and storage tanks.
Water Treatment Facilities: Ensures consistent temperatures for sludge and wastewater treatment.
Industrial Manufacturing: Suitable for resin curing, cleaning baths, and temperature-controlled processing.
Choosing EXHEAT Atex Immersion Heaters ensures a balance of safety, efficiency, and reliability. These heaters are specifically designed for hazardous locations in the UAE, offering guaranteed compliance with ATEX Directive 2014/34/EU and IECEx standards.
With IP66/IP67-rated protection, they resist dust, salt, and humidity common in Dubai’s industrial zones. Each unit is designed for easy installation, minimal maintenance, and seamless integration with control systems. When you choose Atex Hub as your supplier, you also get certified documentation, technical support, and after-sales service across Dubai, Abu Dhabi, and Sharjah.
| Parameter | Specification |
|---|---|
| Product Name | EXHEAT Hazardous Area Immersion Heaters |
| Certification | ATEX & IECEx (Gas and Dust) |
| Zone Classification | Zone 1, Zone 2, Zone 21, Zone 22 |
| Power Rating | 1 kW to 500 kW (customizable) |
| Voltage Options | 230V / 400V / 690V AC (1 or 3 Phase) |
| Material (Sheath) | SS316L, Incoloy 800/825, Inconel |
| Mounting Type | Flanged or Threaded (Screw Plug) |
| Enclosure Type | Ex d (Flameproof) / Ex e (Increased Safety) |
| Ingress Protection | IP66 / IP67 |
| Temperature Class | T3 / T4 (model dependent) |
| Control Options | Thermostat, RTD, Thermocouple |
| Applications | Oil & gas, water, chemicals, marine, power, and utilities |
ATEX Directive 2014/34/EU – Equipment for Explosive Atmospheres
IECEx Scheme – International Certification for Ex Equipment
EN 60079-0 – Explosive Atmospheres: General Requirements
EN 60079-1 – Flameproof Enclosure “d” Protection
EN 60079-7 – Increased Safety “e” Protection
IEC 60529 – IP Ratings (IP66/IP67)
1) What makes EXHEAT immersion heaters suitable for Dubai?
They are built to withstand heat, dust, and humidity while maintaining ATEX/IECEx compliance for hazardous areas.
2) Are these heaters certified for use in explosive zones?
Yes, they are ATEX & IECEx certified for Zone 1, Zone 2, Zone 21, and Zone 22.
3) Can I use them for oil and water heating applications?
Absolutely. They are ideal for oil, water, and chemical heating in tanks and vessels.
4) How are EXHEAT immersion heaters controlled?
Each unit can fitted with thermostats, RTDs, or thermocouples for precise temperature regulation.
5) Do they come in different power ratings?
Yes, power ratings are customizable from 1 kW up to 500 kW, depending on your process needs.
6) Are they suitable for outdoor and marine use?
Yes, with IP66/IP67 protection, they perform reliably in offshore, onshore, and coastal sites.
7) Where can I buy EXHEAT immersion heaters in Dubai?
You can purchase authentic EXHEAT Hazardous Area Immersion Heaters from Atex Hub, the trusted supplier in Dubai, Abu Dhabi, and Sharjah.
The EXHEAT Hazardous Area Immersion Heaters are the most reliable and efficient solution for process and utility heating in hazardous areas across the UAE. Certified under ATEX and IECEx, they ensure total safety in explosive atmospheres. Designed for Dubai’s demanding environments and available through Atex Hub, they provide exceptional durability, precision, and compliance for oil, water, and chemical heating applications.