If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The ATex Roof Helicoidal THT-R is a tough, Ex-rated roof exhaust that moves big air volumes in hazardous gas and dust zones—without compromising safety. Using an ATEX/IECEx motor and a helicoidal (axial) impeller, it delivers high flow rates with low pressure loss, making it perfect for general extraction on large roofs and open process buildings. A weather cowl with splash protection and bird guard keeps the inlet clear, while vertical or side discharge adapters help control plume direction on crowded rooftops. Built for the UAE climate, the THT-R uses corrosion-resistant materials, UV-stable finishes, and IP-rated entries to handle heat, dust, humidity, and salt-spray across Dubai, Sharjah, and Abu Dhabi. For fast installation, dependable ventilation, and audit-ready compliance, choose Atex Helicoidal in UAE – THT-R, available locally from Atex Hub.
An Atex helicoidal unit is an axial-flow, roof-mounted ventilator engineered to extract flammable vapours and dusts while preventing the equipment itself from becoming an ignition source. The THT-R combines a helicoidal (axial) propeller with an Ex-certified motor inside a robust roof turret and protective cowl. Compared with centrifugal roof fans, helicoidal units move very high volumes at lower static pressures, making them ideal for large spaces, short duct runs, or free discharge applications. Every interface—motor, cabling, earthing, surface temperature—is designed to meet Ex rules. In the UAE, where bright sun, airborne dust, and coastal air can punish ordinary fans, the THT-R keeps airflow consistent on analyser houses, workshops, solvent stores, and open bays across Dubai, Sharjah, and Abu Dhabi.
The THT-R is selected whenever you need big, reliable extraction without complex ductwork. Use it to dilute flammable vapours in paint touch-up zones, clear warm process air from workshops and pump halls, and provide night purge in production buildings. For battery rooms and charging bays, it supports hydrogen dilution when paired with detectors and alarm-boost logic. In powder areas, it helps maintain background airflow to reduce dust accumulation (pair with localized capture where needed). Because the system installs quickly and produces high free-air flow, teams in Dubai, Sharjah, and Abu Dhabi can improve air quality across large floor areas with fewer units and simpler maintenance.
Oil & Gas / Petrochemicals: General extract in MCC annexes, lube-oil rooms, analyser shelters, and tank farm shelters where high volume flow is needed.
Marine & Ports: Dockside stores, paint prep, and pump rooms exposed to spray and salt air—areas that benefit from sealed, corrosion-resistant construction.
Utilities & Water: Chemical dosing huts and chlorination rooms requiring steady background fume dilution with compliant electrics.
Food, Pharma & Chemical: Powder and solvent handling spaces where general airflow complements local LEV.
Industrial Workshops & Battery Rooms: Warm air removal and hydrogen dilution on forklift/UPS charging bays in classified zones.
Choose the THT-R for high airflow, simple installation, and low life-cycle cost. The helicoidal propeller provides excellent m³/h per watt, ideal for large-volume spaces with limited resistance. The turret’s cowl protects against rain and sand, while optional vertical or horizontal discharge accessories fit rooftop constraints. With Ex-rated motors in common UAE voltages and optional VFD control, you can tune airflow for day/night or process changes. Materials and hardware are specified for UV, dust, and coastal corrosion. Backed by Atex Hub for local selection support, you’ll match duty point (m³/h @ Pa) and Ex code to your site standard—keeping commissioning swift and audits smooth.
| Item | Specification |
|---|---|
| Model | ATex Roof Helicoidal – THT-R Series |
| Airflow Range | Approx. 3,000 – 45,000 m³/h (size & duty dependent) |
| Static Pressure | Up to 250–350 Pa (model dependent; best for low/medium resistance) |
| Protection Concept | ATEX/IECEx aligned; Ex motor options for gas/dust zones (final Ex code on nameplate) |
| Motor Options | 2-/4-pole IE2/IE3, 50/60 Hz, 230/400/690 V AC (variant dependent) |
| Impeller Type | Helicoidal (axial); anti-spark blade/fastener design |
| Materials | Powder-coated steel or 316 stainless steel cowl; aluminium/polymer blades (model dependent) |
| Ingress Protection | Turret/entries IP55–IP66 (installation dependent) |
| Operating Temperature | −20 °C to +55 °C continuous (higher by request & Ex class) |
| Discharge | Vertical as standard; horizontal side-outlet kit optional |
| Mounting | Roof curb / flange plate; vibration pads; wall plinth option |
| Controls | DOL / Star-Delta; VFD with Ex-rated motor (verify compatibility) |
| Noise (Free Field) | 60–80 dB(A) @ 3 m typical (size & duty dependent) |
| Cable Entries | Metric/NPT Ex glands; internal earth points |
| Compliance | ATEX/IECEx, IEC 60079 explosive atmospheres; IEC 60529 IP; ISO 5801 fan performance |
| Maintenance | Access for cleaning; sealed or grease-for-life bearings (model dependent) |
1) When is a helicoidal turret better than a centrifugal one?
Use helicoidal when you need very high airflow with low to medium resistance and short duct runs—ideal for large spaces and general extract.
2) Can I control the THT-R with a VFD?
Yes—when paired with a VFD-ready Ex motor and correct cabling/filters. This enables night purge and process-driven boost modes.
3) How do I size the unit?
Share room volume, target ACH, contaminant type, and any duct losses. We’ll select a duty point (m³/h @ Pa) that meets process and code needs.
4) Is it suitable for coastal Abu Dhabi and Dubai?
Yes—specify 316 SS cowl, marine coatings, and IP66 entries for salt-spray environments.
5) Can the discharge be horizontal?
Yes—order the side-outlet kit to direct exhaust away from nearby intakes, walkways, or height-restricted zones.
6) What maintenance is required?
Periodically clean the cowl and impeller, check gland torque and fixings, and verify airflow switch or DP set-points during PM rounds.
7) Does it work for hydrogen in battery rooms?
Yes—use continuous low-speed extraction with alarm-driven boost, linked to hydrogen detectors and your F&G logic.
For high-volume, Ex-compliant ventilation that stands up to UAE conditions, the ATex Roof Helicoidal THT-R delivers. It installs fast, moves serious air, and keeps compliance straightforward across Dubai, Sharjah, and Abu Dhabi. With local specification help and supply from Atex Hub, you’ll achieve the right duty point, documentation, and durability for long, trouble-free service. When airflow over large areas matters, choose Atex Helicoidal in UAE – THT-R.