The ATEX Heating Mantle Type WHI is an explosion-proof electric heating mantle for flasks used in hazardous areas. It delivers smooth, even heat to round-bottom glassware from 250 ml to 20 L, keeping reactions stable and repeatable while limiting ignition risks. A tough, antistatic outer, Ex-rated internals, and integrated temperature limiting protect both the process and the operator. Choose models to suit common lab and pilot-plant tasks—distillation, reflux, evaporation, solvent swaps, and gentle heating of viscous media. Ideal for chemical, oil & gas, pharma, food labs, and pilot lines across Dubai, Sharjah, and Abu Dhabi. If you’re searching for a digital heating mantle, 5L heating mantle, or electric heating mantle that meets Ex rules, the WHI is a reliable, UAE-ready choice. Available at Atex Hub.
An Atex Heating Mantle is a certified mantle that heats laboratory flasks in explosive atmospheres (Ex). Instead of improvised hot plates or unprotected heaters, you get uniform heat, PID accuracy (with compatible controllers), and limited surface temperature to support ATEX/IECEx compliance. In the UAE—especially Dubai, Sharjah, and Abu Dhabi—teams use WHI mantles to run day-to-day distillations, reflux steps, solvent recovery, and sample prep without leaving the Ex zone. It’s simple: set the temperature, secure the flask, and run your method with steady heating and less rework.
Distillation & reflux for solvents and process intermediates where stable temperature is critical.
Evaporation & concentration with consistent heat to reduce overshoot and thermal shock.
Solvent swap & dehydration steps that need gentle, even heating under Ex rules.
Viscosity control for waxy or resinous media before filtration or transfer.
QA/QC sample prep with repeatable conditions across shifts.
Oil & Gas / Marine labs: Water-cut checks, solvent treatment, sample processing in Ex bays.
Chemical & Paint labs: Resins, binders, and pigments heated with even mantle contact.
Pharma & Food pilot lines: Heating under controlled conditions for ingredients and actives.
Education & training in Ex areas: Safe demonstrations and operator up-skilling.
R&D skids: Compact, electric heating mantle solutions next to reactors or columns.
Ex safety first: Construction limits hot surfaces and controls ignition sources.
Process accuracy: Works with digital controllers for PID, ramp/soak, and tight setpoints.
Human-friendly: Robust shell, easy flask loading, and clear labelling reduce operator error.
UAE-fit support: Atex Hub helps match flask size, wattage, sensor type, and temperature class to your zone.
Lower total cost: Fewer failed runs, faster set-up, and durable components built for daily use.
| Technical Specifications | ATEX Heating Mantle Type WHI |
|---|---|
| Flask Capacity Range | 250 ml, 500 ml, 1 L, 2 L, 3 L, 5 L, 10 L, 20 L |
| Heating Element | Wound heating mantle coil with even contact |
| Power Rating | ~150 W (250 ml) up to ~2000 W (20 L) |
| Supply Voltage | 230 V AC, single phase |
| Temperature Control | Works with external digital mantle controller / PID |
| Sensor Compatibility | Pt100 RTD / Type-K (model-dependent) |
| Operating Range | Ambient to ~450 °C mantle surface (media & glassware dependent) |
| Surface Temp Limiting | Ex temperature-class compliant (model-specific) |
| Inner Liner | Glass-fibre / high-temp textile for flask conformity |
| Outer Jacket | Antistatic, wipe-clean, industrial duty |
| Earthing | External grounding point |
| Protection Class | IP54 or higher (model-specific) |
| Zone Suitability | Gas: Zone 1/2; Dust: Zone 21/22 (model-specific) |
| Temperature Class | T3/T4 (model-specific) |
| Cable Entries | Ex glands (M20/M25) |
| Mounting | Bench / frame / skid integration |
| Documentation | Ex certificate, User manual, Declaration of Conformity |
| Warranty | 12 months |
ATEX Directive 2014/34/EU (EUR-Lex) – equipment for explosive atmospheres
IECEx Certified Equipment Scheme – international certification & certificate lookup
IEC 60079-0 – Explosive atmospheres—Equipment—General requirements
IEC 60079-11 – Intrinsically safe “i”
IEC 60079-31 – Dust ignition protection by enclosure “t”
1) What flask sizes does the WHI support?
From 250 ml up to 20 L. Common requests in the UAE include 500 ml, 5 L, and 10 L.
2) Is it a digital heating mantle?
The mantle is Ex-heated; pair it with a digital heating mantle controller for PID accuracy and profiles.
3) Can I run distillation in Zone 1?
Yes—select the correct ATEX/IECEx marking, gas group, and temperature class for your area classification.
4) Does the mantle work with beakers?
Designed for round-bottom flasks. For beakers, use compatible mantles or hot plates; ask Atex Hub for options.
5) How do I avoid overshoot?
Use a PID controller with Pt100/Type-K sensing and ramp/soak where needed.
6) Is maintenance difficult?
Routine checks of leads, glands, and earthing are usually enough. Keep the outer clean and dry.
7) Can I get a 5L heating mantle quickly in Dubai?
Yes—Atex Hub supports local delivery and sourcing for Dubai, Sharjah, and Abu Dhabi.
For safe, repeatable heating in Ex labs and pilot plants, the ATEX Heating Mantle Type WHI brings together uniform heat, Ex compliance, and UAE-ready practicality. Whether you need a 5L heating mantle, digital heating mantle control, or a robust electric heating mantle for daily work, WHI helps you hit setpoints faster and keep them steady—run after run. Talk to Atex Hub to match flask size, wattage, and certification to your site.