If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The Atex Enclosure CCF is a compact, tough, and ATEX/IECEx-certified electrical enclosure designed to keep switches, terminals, and small control gear safe in hazardous areas. Built for the Gulf’s dust, heat, and coastal air, it protects connections from moisture and ignition risks—perfect for projects across Dubai, with strong adoption in Abu Dhabi and Sharjah. If you need an atex enclosure box, ex e junction box, or atex terminal box that installs fast and lasts long, the CCF range delivers reliability and clean cable management. Supplied by Atex Hub in the UAE, it arrives with the right documents so you can commission quickly and stay compliant.
An Atex Enclosure is a certified housing that isolates electrical parts from explosive atmospheres. The Atex Enclosure CCF uses Ex e (increased safety) and/or Ex d (flameproof) protection (model dependent) to prevent sparks or hot parts from igniting the outside environment. Think of it as a safe, sealed box for pushbuttons, pilot lamps, terminal rails, and small relays. In Dubai’s coastal plants and sandy yards across the UAE, sealing and coatings matter. The CCF’s weather-tight design, corrosion-resistant materials, and clear internal layout help you reduce faults, speed inspection, and extend equipment life.
Use the CCF wherever you need tidy terminations or local control in Ex zones. Typical tasks include pump start/stop stations, ESD/reset points, lighting loops, small motor junctions, and instrument marshalling. In Dubai, Abu Dhabi, and Sharjah, technicians value the space for neat wiring, the labelled rails, and the flexible gland options. These details cut installation time, simplify audits, and keep day-to-day operations running smoothly—especially in areas exposed to salt spray, sand, or high humidity.
Oil & Gas / Petrochem: Skid control posts, meter stations, heater feeds, analyser shelters.
Marine & Ports: Jetty power/tie-ins, loading arm controls, navigation aid junctions.
Chemicals & Industrial: Solvent area panels, blending lines, packaging machinery tie-ins.
Utilities & Power: Water treatment galleries, blower rooms, MCC interlocks.
Warehousing & Bulk Handling: Dusty conveyor zones needing atex zone 22 enclosures.
Buildings & HVAC: E-stops, fan starters, damper control in Ex-rated plant areas.
The Atex Enclosure CCF offers the balance of compliance, durability, and easy installation. You get ATEX/IECEx safety, IP66/67 ingress protection, and materials that stand up to the UAE climate. Cable entries are flexible (metric/NPT), internal DIN rails make wiring simple, and earthing points are clear and accessible. For engineering teams, that means faster build, cleaner layouts, and stress-free inspections. Backed by Atex Hub with local support in Dubai, Abu Dhabi, and Sharjah, you’ll have the drawings, certificates, and test reports ready for your safety file.
| Parameter | Specification |
|---|---|
| Product Name | Atex Enclosure CCF |
| Certifications | ATEX, IECEx (gas and/or dust variants) |
| Protection Concepts | Ex e (increased safety) and/or Ex d (flameproof), model dependent |
| Zone Classification | Gas: Zone 1 / Zone 2; Dust: Zone 21 / Zone 22 |
| Gas Groups / T-Class | IIB/IIC (per model), T6–T4 (design dependent) |
| Ingress Protection | IP66 / IP67 (IEC 60529) |
| Body Materials | Marine-grade aluminium alloy or stainless steel; epoxy/polyester coating |
| Internal Fittings | DIN rail, earth stud, mounting plate, terminal blocks as specified |
| Cable Entries | M20–M40 (typical) or NPT equivalents; gland plates & stopping plugs available |
| Options | Windowed cover, legend plates, door interlock, anti-condensation pack (Ex variant) |
| Ambient Rating | −40 °C to +55 °C (extended ranges available) |
| Typical Devices | Pushbuttons, selector switches, E-stops, pilot lamps, small relays/I-O |
| Documentation | Datasheet, GA drawing, wiring/terminal schedule template, test report, ATEX/IECEx certs |
ATEX Directive 2014/34/EU – equipment for explosive atmospheres
IECEx Scheme – international certification for Ex equipment
EN 60079-0 – Explosive atmospheres: General requirements
EN 60079-1 – Protection by flameproof enclosure “d”
EN 60079-7 – Protection by increased safety “e”
IEC 60529 – IP ratings (IP66/IP67)
1) Can I fit my own pushbuttons and lamps for Dubai plants?
Yes. The CCF supports certified devices. We’ll confirm cut-outs, entry sizes, and labels to keep the build compliant and tidy.
2) Is it suitable for coastal Abu Dhabi terminals?
Absolutely. The coated body, stainless hardware, and IP66/67 sealing handle saline air and humidity.
3) Does it work for dust zones in Sharjah warehouses?
Yes—choose the dust-certified variant for Zone 21/22 and use approved dust-rated cable glands.
4) How many cable entries can I have?
As your schedule requires. The CCF offers multiple entry sizes, gland plates, and certified stopping plugs.
5) Can I add a viewing window or legend plates?
Yes—windowed covers and custom legends are available. We’ll ensure Ex and IP ratings remain intact.
6) What ambient range is typical in the UAE?
Standard designs cover −40 °C to +55 °C; extended ranges are available on request.
7) Do I get full documentation from Atex Hub?
Yes. You’ll receive ATEX/IECEx certificates, GA drawings, terminal templates, and test/inspection reports for audit-ready commissioning.
For clean, compliant terminations and local controls in hazardous areas, the Atex Enclosure CCF is a dependable choice. It pairs ATEX/IECEx safety with installer-friendly details and weather-tight durability—ideal for Dubai, Abu Dhabi, and Sharjah projects. With Atex Hub support, you get the right configuration, complete documents, and long service life—so your operations in the UAE stay safe and on schedule.