If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The Atex Push Buttons PB1-1 Series are compact, Ex-rated control boxes/push button stations built for hazardous gas and dust zones. Each station gives operators a clear, glove-friendly interface for start, stop, reset, and emergency stop functions right where the work happens—beside pumps, fans, skids, conveyors, and valves. With rugged housings, high ingress protection, and Ex-compatible cable entries, the PB1-1 Series performs day after day in the UAE’s heat, dust, humidity, and salt air across Dubai, Sharjah, and Abu Dhabi. If you want simple local control that passes audits and is easy to maintain, choose the Atex Control Box in Dubai—PB1-1 Series, available from Atex Hub.
An Atex control box is a sealed push button station designed to operate safely in or near explosive atmospheres. The PB1-1 Series combines Ex-certified enclosures (e.g., Ex d / Ex e / Ex t variants) with reliable operators and contact blocks that prevent sparking and control surface temperatures. This means you can place control points close to the process without risking ignition. In Dubai and the wider UAE, equipment faces bright sun, airborne dust, sandstorms, washdowns, and coastal corrosion. The PB1-1 Series tackles this with UV-stable materials, corrosion-resistant hardware, and IP66/67 sealing, so your push button stations stay readable, responsive, and safe for years. Each unit arrives labelled, wired, and ready to integrate, cutting installation time and helping you standardize controls across sites.
The PB1-1 Series serves as your go-to local control point where fast, clear action matters. Use it to start/stop motors, acknowledge alarms, trigger emergency stops, and select operating modes with simple selector switches. On skids and remote panels, operators can jog equipment during maintenance or isolate a device before work. Clear actuator colours (green start, red stop/E-stop, yellow reset), crisp legends, and glove-friendly buttons reduce confusion in noisy environments. Because each station accepts different contact combinations and legends, you can deploy the same family for multiple roles—streamlining spares and training across Dubai, Sharjah, and Abu Dhabi.
Oil & Gas / Petrochemicals: Pump skids, separators, tank farms, compressor shelters, chemical dosing panels where Ex compliance is mandatory.
Marine & Ports: Pump rooms, jetties, and deck machinery that face spray, vibration, and salt air—stations must be sealed and tough.
Utilities & Water: Chlorination rooms, MCC outstations, and remote kiosks where clear, Ex-rated local control improves safety.
Food, Pharma & Chemical: Powder and solvent areas needing clearly labelled push buttons that are easy to clean and inspect.
Industrial Facilities & Warehousing: HVAC, mixers, conveyors, and battery-charging zones—local start/stop/E-stop improves response time.
Each application benefits from the PB1-1’s durable enclosure, readable labelling, and flexible contact options, helping teams work faster and safer.
Choose the PB1-1 Series for simplicity, durability, and fast deployment. Enclosures in 316 stainless steel or GRP resist corrosion and UV. Metric and NPT entries match existing conduit, while IP66/67 sealing protects against dust and water. The internal layout keeps wiring tidy and maintenance quick. With Atex Hub in the UAE, you get correct Ex markings, thread forms, legend sets (Arabic/English), and drawings/nameplates that speed approvals. Standardizing on PB1-1 reduces engineering time, simplifies spares, and keeps inspections straightforward across Dubai, Sharjah, and Abu Dhabi.
| Item | Specification |
|---|---|
| Model | Atex Push Buttons PB1-1 Series (Ex control box / push button station) |
| Protection Concepts | Ex d (flameproof), Ex e (increased safety), Ex t (dust) – variant dependent |
| Enclosure Materials | 316 stainless steel or GRP (glass-reinforced polyester); corrosion-resistant hardware |
| Operators | Momentary/maintained push buttons, Emergency Stop (mushroom, twist-to-release), selector |
| Contacts | 1NO/1NC standard; options 2NO/2NC (up to 4 blocks, model dependent) |
| Electrical Ratings | Typical AC-15: 230 V / 3 A, DC-13: 24 V / 2 A (contact block dependent) |
| Ingress Protection | Up to IP66/IP67 with approved Ex glands |
| Cable Entries | M20/M25 metric or ½″/¾″ NPT; stopping plugs; earth tag |
| Ambient Temperature | −40 °C to +55 °C (variant dependent) |
| Markings & Legends | Arabic/English legends; ISO/IEC symbols; laser/engraved nameplates |
| Mounting | Wall/panel mounting; stainless fixings; internal earth point |
| Accessories | Guarded E-stop hood, padlock hasp, pilot lamps, tag plates, sealing washers |
| Compliance | ATEX/IECEx aligned; exact Ex code on supplied label/datasheet |
1) Which protection type should I choose—Ex d or Ex e?
Use Ex d when you need flameproof containment; use Ex e for increased safety with non-sparking internals. Selection depends on zone, gas group, and device type.
2) Can I add an Emergency Stop later?
Yes. Order a PB1-1 with E-stop from the start or add a dedicated E-stop station. Ensure contact ratings and the safety loop meet your risk assessment.
3) Do you support Arabic/English legends?
Absolutely—dual-language legends and ISO/IEC symbols help pass audits in the UAE.
4) What IP rating is suitable outdoors?
With correct Ex glands and sealing washers, PB1-1 achieves IP66/67. Always torque glands and inspect seals during PM rounds.
5) How many contacts can one station carry?
Most PB1-1 configurations support up to four contact blocks (model dependent). Confirm I/O needs before ordering.
6) Are both metric and NPT threads available?
Yes—M20/M25 and ½″/¾″ NPT entries, plus certified reducers/adapters to maintain Ex/IP integrity.
7) Where should I place the control boxes?
Install along escape routes and access points near the equipment being controlled, following your site layout and HSE plan.
The Atex Push Buttons PB1-1 Series offer simple, rugged, and compliant local control for hazardous areas across Dubai, Sharjah, and Abu Dhabi. With clear operators, flexible contacts, and sealed enclosures, they make day-to-day operation safer and audits easier. Supported locally by Atex Hub, the PB1-1 Series helps you standardize on a trustworthy Atex Control Box in Dubai—from specification to installation and long-term maintenance.