If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The Atex Vertical-Flow Centrifugal Turret is a robust, Ex-rated roof extractor that keeps your air safe and moving in hazardous gas and dust zones. Powered by a high-efficiency centrifugal impeller and ATEX/IECEx motor options, it delivers strong airflow at useful pressure—exactly what you need for ducted runs, filters, and long pathways. Its vertical discharge throws contaminated air upwards to reduce re-entrainment near nearby intakes, skylights, or walkways. With corrosion-resistant construction and IP-rated entries, the unit stands up to heat, dust, humidity, and salt-spray across Dubai, Sharjah, and Abu Dhabi. If you want dependable extraction that installs quickly and passes audits, choose the Atex Centrifugal Turrets in UAE, available locally from Atex Hub.
An Atex centrifugal turret is a roof-mounted exhaust unit designed to remove flammable vapours, fumes, and fine dusts from classified areas without becoming an ignition source. The vertical-flow design pairs a pressure-capable centrifugal wheel with an Ex-certified motor inside a weather-protected cowling. Unlike basic fans, every interface—surface temperature, electrics, earthing, and cable entries—is engineered to Ex rules. Because it discharges straight up, the plume disperses above roof level, helping reduce odour, heat build-up, and recirculation. Built for the UAE’s climate, the turret uses UV-stable finishes, stainless options, and tight sealing to stay reliable on analyser rooms, solvent stores, battery rooms, and process buildings across Dubai, Sharjah, and Abu Dhabi.
The vertical-flow turret is chosen when sites need reliable, code-aligned extraction that handles duct losses and filters:
Hydrogen ventilation for battery-charging/UPS rooms with low-speed run and alarm-driven boost.
VOC/solvent removal in paint, cleaning, and mixing areas to maintain concentrations below LEL.
Dust extraction for powder tipping, weighing, and blending rooms.
Negative-pressure control around analyser shelters, dosing huts, and process skids.
Turnaround/hot-work support, providing higher extraction during confined-space tasks.
Oil & Gas / Petrochemicals: Analyzer houses, lube-oil rooms, tank farm cabinets, solvent stores.
Marine & Ports: Pump rooms, paint shops, dockside stores where spray and salt demand sealed, corrosion-resistant gear.
Utilities & Water: Chlorination rooms and chemical dosing huts needing continuous fume removal.
Food, Pharma & Chemical: Powder and solvent handling with cleanable surfaces and controlled airflow.
Battery Rooms & Workshops: Hydrogen management for forklift/UPS chargers and maintenance bays in classified zones.
Choose the Atex Vertical-Flow Centrifugal Turret for safety, pressure performance, and long service life. The centrifugal wheel delivers the static pressure that axial fans often lack, keeping flow stable through ducts and filters. Housings and fasteners are specified for UV, dust, and coastal corrosion, and motors are available for common UAE voltages with VFD options. Installation is straightforward using standard roof curbs, Ex glands, and clear wiring paths. With Atex Hub support, you’ll match the duty point (m³/h @ Pa), Ex code, and controls to your process—so commissioning is faster and audits are smoother throughout Dubai, Sharjah, and Abu Dhabi.
| Item | Specification |
|---|---|
| Model | Atex Vertical-Flow Centrifugal Turret (Roof Extractor) |
| Airflow Range | Approx. 1,000 – 20,000 m³/h (size & duty dependent) |
| Static Pressure | Up to 800 Pa (model dependent) |
| Protection Concept | ATEX/IECEx aligned; Ex gas/dust motor options (final Ex code on nameplate) |
| Motor Options | 2-/4-pole IE2/IE3, 50/60 Hz, 230/400/690 V AC (variant dependent) |
| Discharge Direction | Vertical plume; weather cowl with ingress/bird guard |
| Materials | Powder-coated steel or 316 stainless steel cowl; aluminium/PP anti-spark impeller |
| Ingress Protection | Turret/entries IP55–IP66 (installation dependent) |
| Operating Temperature | −20 °C to +55 °C continuous (higher by request & Ex class) |
| Mounting | Roof curb / flange plate; vibration pads; wall plinth option |
| Controls | DOL / Star-Delta; VFD with Ex-rated motor (verify compatibility), airflow switch option |
| Noise (Free Field) | 58–78 dB(A) @ 3 m typical (size & duty dependent) |
| Duct Interfaces | Round/rectangular adaptors; backdraft damper / non-return options |
| Cable Entries | Metric/NPT Ex glands; internal earth points |
| Compliance | ATEX/IECEx, IEC 60079 explosive atmospheres; IEC 60529 IP; ISO 5801 performance test |
| Maintenance | Access panel for cleaning; sealed or grease-for-life bearings (model dependent) |
1) Why choose a vertical-flow turret?
It throws exhaust upwards, helping dispersion above roof level and reducing recirculation into nearby intakes or walkways.
2) Can I use a VFD?
Yes—pair with a VFD-ready Ex motor and correct cabling/filters for night-setback and boost modes.
3) How do I size the unit?
Provide room volume, target ACH, contaminant type, and duct losses. We’ll select a duty point (m³/h @ Pa) that meets process and code needs.
4) Suitable for coastal Abu Dhabi and Dubai?
Yes—specify 316 SS, marine coatings, and IP66 entries for salt-spray environments.
5) Does it work for hydrogen in battery rooms?
Yes—use continuous low-speed extraction with alarm-driven boost, linked to hydrogen detectors and your F&G logic.
6) What maintenance is required?
Clean the cowl/impeller, check gland torque and fixings, and verify airflow switch or DP set-points during PM rounds.
7) Can it be wall-mounted?
Roof mounting is standard, but wall plinth options exist. Confirm discharge direction, weather protection, and airflow path before selection.
For safe, dependable extraction in hazardous areas, the Atex Vertical-Flow Centrifugal Turret offers the pressure, durability, and control your site needs. Engineered for UAE conditions and supported locally by Atex Hub, it simplifies specification, speeds installation, and keeps air quality under control across Dubai, Sharjah, and Abu Dhabi. When ventilation is mission-critical, choose the Atex Centrifugal Turrets in UAE that’s built for the job.