

If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The Atex Axial Centrifugal Turrets THTR provide powerful, safe ventilation for hazardous gas and dust zones across the UAE. Built on an Ex-rated motor/impeller set inside a corrosion-resistant turret housing, the THTR moves high air volumes while controlling ignition risks and weather ingress. It’s designed for hot rooftops in Dubai, dusty yards in Sharjah, and coastal plants in Abu Dhabi. With simple mounting, a service-friendly design, and multiple control options, this Atex Centrifugal Turret in UAE helps keep workspaces clear of fumes and fine particulates—ready for audits and day-to-day reliability.
An ATEX centrifugal turret is a roof- or wall-mounted exhaust unit that combines an Ex-rated motor with a centrifugal or mixed-flow impeller inside a weatherproof cowling. Unlike standard fans, the THTR limits electrical energy, surface temperature, and sparking at all interfaces to prevent ignition in explosive atmospheres. The ventilator discharges vertically to keep rain and sand out while purging vapours efficiently from rooms, skids, and enclosures. For the UAE’s climate—high ambient temperatures, airborne dust, and salt-spray—the THTR uses robust coatings, UV-stable plastics or 316 stainless steel options, and IP-rated cable entries to deliver safe, continuous ventilation on process buildings, tank farms, battery rooms, and pump halls.
The THTR is the go-to solution when you need reliable extraction with Ex compliance. Use it to clear flammable vapours from solvent stores, purge corrosive fumes from dosing rooms, and maintain negative pressure around process skids. Facilities also deploy THTR units for battery-charging areas to evacuate hydrogen, for paint rooms to remove overspray and VOCs, and for powder handling to control fine dust. Because the turret exhausts vertically, it reduces re-entrainment and protects nearby air intakes. With optional speed control and airflow monitoring, teams in Dubai, Sharjah, and Abu Dhabi can tune ventilation to shift patterns, night-time maintenance, and seasonal heat loads.
Oil & Gas / Petrochemicals: MCC shelters, analyser houses, lube oil rooms, tank farm cabinets, and nitrogen/solvent areas needing continuous, Ex-compliant exhaust.
Marine & Ports: Pump rooms, paint shops, and dockside stores where vibration, spray, and salt air demand sealed, corrosion-resistant turrets.
Utilities & Water: Chlorination rooms and chemical dosing huts requiring constant fume removal with safe electrical design.
Food, Pharma & Chemical: Powder rooms and solvent prep where dust/VOC extraction and cleanable surfaces are critical.
Battery Rooms & Workshops: Hydrogen extraction for forklift chargers and UPS rooms, plus general maintenance bays in classified zones.
Choose THTR for a balance of safety, airflow, and low life-cycle cost. The impeller’s aerodynamics deliver strong pressure capability for ducted runs while keeping noise in check. The enclosure and fasteners are specified for UV, dust, and coastal corrosion, and the Ex-rated motor options align with common UAE voltages. Installation is straightforward: standard roof curbs, integral backdraft features, and Ex-compatible cable glands make commissioning faster. With local stocking and guidance from Atex Hub, you’ll match size, Ex code, duty point (m³/h @ Pa), and controls to your exact room volume and emission rates—so audits are easier and uptime improves across Dubai, Sharjah, and Abu Dhabi.
| Item | Specification |
|---|---|
| Model | Atex Axial Centrifugal Turrets – THTR Series |
| Airflow Range | Approx. 1,000 – 20,000 m³/h (size & duty dependent) |
| Pressure Capability | Up to 800 Pa static (model dependent) |
| Protection Concept | ATEX/IECEx aligned; Ex motor options for gas/dust zones (final Ex code on nameplate) |
| Motor Options | 2-pole / 4-pole IE2/IE3; 50/60 Hz; 230/400/690 V AC (variant dependent) |
| Materials | Powder-coated steel or 316 stainless steel cowl; aluminium/PP impeller (anti-spark design) |
| Ingress Protection | Turret/cable entries up to IP55–IP66 (install method dependent) |
| Operating Temp | −20 °C to +55 °C continuous (higher by request & Ex class) |
| Discharge | Vertical, weather-protected; integrated bird/ingress guard |
| Mounting | Roof curb / flange plate; wall plinth option; vibration pads |
| Controls | DOL/Star-Delta, VFD with Ex-rated motor (check motor/VFD compatibility), airflow switch option |
| Noise (Free Field) | 58–78 dB(A) @ 3 m typical (size & duty dependent) |
| Duct Interfaces | Round/rectangular adaptors; backdraft damper / non-return options |
| Cable Entries | Metric/NPT Ex glands; internal earth points |
| Compliance | ATEX/IECEx; IEC 60079 series; IEC 60529 IP; ISO 5801 performance test (where used) |
| Maintenance | Access panel for cleaning; grease-for-life bearings (model dependent) |
1) Axial or centrifugal—what’s the difference for THTR?
THTR uses a centrifugal or mixed-flow impeller for better pressure at the same airflow, ideal for ducted runs or filters. Axial suits short paths; centrifugal handles resistance.
2) Can I run THTR on a VFD?
Yes—when supplied with an Ex-rated motor compatible with VFDs and correct cabling/filters. Atex Hub can help validate the package.
3) How do I size the turret for my room?
Define air changes per hour (ACH) and contaminants. Provide room volume, duct losses, and target pressure; we’ll select a duty point m³/h @ Pa.
4) Is it suitable for coastal sites in Abu Dhabi or Dubai?
Yes—select 316 SS cowl and hardware, IP66 entries, and marine-grade coatings for long life in salt-spray environments.
5) What about hydrogen in battery rooms?
Choose continuous low-speed extraction with alarm-driven boost and hydrogen detectors. Verify compliance with your local code and classification.
6) How often is maintenance required?
Plan periodic cleaning of the impeller/cowl, check gland torque and fasteners, and verify airflow switch or DP sensors during PM rounds.
7) Can THTR be wall-mounted?
Roof mounting is standard, but wall plinth versions exist for specific layouts. Confirm discharge direction and weather protection.
For safe, dependable extraction in classified areas, the Atex Axial Centrifugal Turrets THTR deliver the airflow and compliance you need—without the headaches. Engineered for the UAE climate and supported locally by Atex Hub, they simplify specification, speed installation, and keep air quality within limits in Dubai, Sharjah, and Abu Dhabi. When ventilation is mission-critical, choose the Atex Centrifugal Turret in UAE that’s purpose-built for hazardous areas.