If you have any questions before making a purchase chat with our online operators to get more information.
Ask An Expert
The Atex Centrifugal Roof Extractor delivers safe, powerful extraction in hazardous gas and dust zones where conventional fans are not permitted. Built around an Ex-rated motor and centrifugal impeller, the turret provides steady airflow while controlling ignition sources. Its weatherproof cowl, vertical discharge, and corrosion-resistant build make it ideal for hot rooftops in Dubai, dusty yards in Sharjah, and coastal plants in Abu Dhabi. With straightforward mounting, multiple sizes, and simple maintenance access, this Atex Centrifugal Turret in Dubai helps you keep air quality within limits, pass audits, and protect people and equipment—available at Atex Hub with local support.
An ATEX centrifugal turret is a roof-mounted exhaust unit designed to extract flammable vapours, fumes, and dust from rooms or process areas without becoming an ignition source. Unlike standard roof fans, it uses Ex-certified components, tight temperature control, and safe electrical interfaces to operate in classified zones. The Atex Centrifugal Roof Extractor couples a high-efficiency impeller to an Ex motor inside a weather cowl that directs air upwards, limiting re-entrainment and shielding the opening from rain and sand. In the UAE’s tough climate—high ambient heat, airborne dust, and salt-spray—the turret’s robust materials, UV-stable finishes, and IP-rated entries keep ventilation reliable on analyser houses, battery rooms, solvent stores, and pump halls across Dubai, Sharjah, and Abu Dhabi.
The Atex Centrifugal Roof Extractor is chosen when you need reliable, compliant extraction that’s easy to deploy and maintain. Typical uses include clearing flammable vapours from solvent mixing and paint rooms, maintaining negative pressure in chemical dosing huts, and evacuating hydrogen from battery-charging or UPS rooms. Facilities also use the turret to manage VOC and powder dust levels around package equipment and skids, and to provide boost extraction during planned shutdowns or hot-work. Because the unit exhausts vertically, it reduces the chance of contaminants drifting back into nearby air intakes—important for dense industrial clusters in Dubai and coastal corridors in Abu Dhabi.
Oil & Gas / Petrochemicals: Analyzer shelters, lube-oil rooms, tank farm cabinets, nitrogen/solvent areas needing continuous Ex exhaust.
Marine & Ports: Pump rooms, paint shops, and dockside stores where spray, vibration, and salt air demand sealed, corrosion-resistant construction.
Utilities & Water: Chlorination rooms and chemical dosing huts requiring constant fume removal with compliant electrics.
Food, Pharma & Chemical: Powders and solvent prep where clean, washable surfaces and contained airflow matter.
Battery Rooms & Workshops: Hydrogen management for forklift and UPS chargers, plus general maintenance bays in classified zones.
Choose this extractor for safety, airflow performance, and low life-cycle cost. The centrifugal impeller provides strong pressure capability for ducted runs and filters, while sound levels remain manageable. The housing and fasteners are specified for UV, dust, and coastal corrosion, and motor options match common UAE voltages and controls. Installation is quick with standard roof curbs, Ex-compatible cable glands, and optional airflow monitoring. With Atex Hub in the UAE, you get help sizing the duty point (m³/h @ Pa), selecting the right Ex code, and aligning controls with your DCS/EMS—so commissioning is faster and audits run smoother in Dubai, Sharjah, and Abu Dhabi.
| Item | Specification |
|---|---|
| Model | Atex Centrifugal Roof Extractor (Turret) |
| Airflow Range | Approx. 1,000 – 20,000 m³/h (size & duty dependent) |
| Static Pressure | Up to 800 Pa (model dependent) |
| Protection Concept | ATEX/IECEx aligned; Ex motor options for gas/dust zones (final Ex code on nameplate) |
| Motor Options | 2-pole / 4-pole IE2/IE3, 50/60 Hz, 230/400/690 V AC (variant dependent) |
| Materials | Powder-coated steel or 316 stainless steel cowl; aluminium/PP anti-spark impeller |
| Ingress Protection | Turret/entries IP55–IP66 (installation dependent) |
| Operating Temperature | −20 °C to +55 °C continuous (higher by request & Ex class) |
| Discharge | Vertical, weather-protected with ingress guard |
| Mounting | Roof curb / flange plate; wall plinth option; vibration pads |
| Controls | DOL / Star-Delta; VFD with Ex-rated motor (check compatibility), airflow switch option |
| Noise (Free Field) | 58–78 dB(A) @ 3 m typical (size & duty dependent) |
| Duct Interfaces | Round/rectangular adaptors; backdraft damper / non-return options |
| Cable Entries | Metric/NPT Ex glands; internal earth points |
| Compliance | ATEX/IECEx, IEC 60079 explosive atmospheres; IEC 60529 IP; ISO 5801 performance test |
| Maintenance | Access panel for cleaning; sealed or grease-for-life bearings (model dependent) |
1) Why a centrifugal turret instead of an axial roof fan?
Centrifugal impellers deliver higher static pressure, ideal for ductwork, filters, and longer runs common on industrial sites in Dubai.
2) Can I run the extractor on a VFD?
Yes—when paired with a VFD-ready Ex motor and correct cabling/filters. This enables night-setback or boost modes to save energy.
3) How do I size the unit?
Provide room volume, target ACH, contaminant type, and estimated duct losses. We’ll select a duty point m³/h @ Pa that meets code and process needs.
4) Is it suitable for coastal Abu Dhabi sites?
Yes—specify 316 stainless steel cowl, marine-grade coatings, and IP66 entries for long life in salt-spray environments.
5) What about hydrogen from battery rooms?
Use continuous low-speed extraction with alarm-driven boost, linked to hydrogen detectors and your F&G logic.
6) What maintenance is needed?
Periodically clean the cowl/impeller, check gland torque and fasteners, and verify airflow switch or DP sensor set-points during PM rounds.
7) Can it be wall-mounted?
Roof mounting is standard, but wall plinth versions exist. Confirm discharge direction, weather protection, and airflow path before selection.
For safe, dependable ventilation in classified areas, the Atex Centrifugal Roof Extractor offers the airflow, compliance, and durability your facility needs. Engineered for the UAE climate and available at Atex Hub, it simplifies specification, speeds installation, and keeps air quality under control across Dubai, Sharjah, and Abu Dhabi. When air movement is mission-critical, choose the Atex Centrifugal Turret in Dubai that’s purpose-built for hazardous areas.